01 COA & batch testing

Reading the citicoline COA: assay, water and the salt form

Technical document 01 · Reviewed 2026-11-19 · Citicoline

On this page
  1. The certificate as a test report
  2. Two bases: moisture and the salt form
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The citicoline certificate lists the physical checks, the HPLC identity and assay, water, pH, the heavy-metal panel and the microbiological result. It also has to identify the form, because the free acid and the sodium salt are separate materials with separate CAS numbers and label names. The limits below are the catalog gates; each lot's measured result belongs beside them.

In one line

Without the form, the HPLC basis and the water figure, a citicoline percentage cannot be compared with another certificate.

The certificate as a test report

A laboratory report is read line by line: what was tested, how, against which limit, and what the sample gave. A verdict such as “conforms” is only the summary of those four pieces. The table is the catalog specification, not a batch result; a lot certificate repeats the gate in one column and puts the measured figure in another.

Identity, assay, water and contaminants · citicoline free acid, catalog limits
ParameterMethodRelease limit
AppearanceVisualWhite powder
IdentificationHPLC retention and UV spectrumConforms to the reference
AssayHPLC with UV detection98.0–102.0% (free acid; basis stated)
WaterKarl Fischer titration≤5.0%
pH (5% solution)Potentiometric2.5–4.5
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The identity line is the one that decides whether the powder is citicoline. The assay line decides how much is there, and the water line decides what the assay denominator is. None of the three stands alone. The pH line is specific to a 5% solution of the free acid; it is not a generic statement about every citicoline salt.

Two bases: moisture and the salt form

Two different questions sit under the word basis, and a certificate has to answer both. The first is moisture: the result can be calculated on the powder as received or on the dried solids. The catalog range is 98.0–102.0% by HPLC, but the certificate should say which denominator produced the number. A lot at 98.0% as-is with 5.0% water works out to 103.2% on the dried basis, above the 102.0% ceiling; the same lot at 98.0% anhydrous is about 93.1% as-is. Both figures can be honest, and they are not the same figure.

The second question is the form. The free acid and the sodium salt are separate standards. A sodium-salt result of 98.0% is not 98.0% free acid: the sodium-bearing molecule is 510.31 g/mol against 488.32 g/mol, so the free-acid equivalent is 93.8% of the powder and sodium is about 4.4% of its mass. If the certificate says “citicoline 98%” and nothing else, the reader cannot tell which powder the drum contains.

Three ways a 98.0% assay can be written
Form and basisFree-acid equivalentWhat else moves
Free acid, anhydrous98.0%About 93.1% as-is at 5.0% water
Free acid, as-is98.0% as-isAbout 103.2% on the dried basis, outside the ceiling
Sodium salt, anhydrous93.8%About 4.4% sodium; its own reference standard

The remedy is documentary: name the form in the specification, print the basis in the assay row, and show the water result beside it. When two suppliers are compared, compare the same basis or ask for the calculation.

Release limit versus batch result

Each release limit is the boundary for the lot; each batch result is a measurement. If the result column simply repeats the range, the certificate has not reported a result. Heavy metals belong per element, because a total hides the metal that matters. Microbiology needs a count and an absence statement, not a tick box.

Water is just as important. A figure close to 5.0% passes, but it leaves little room for a humid store or a slow repack. The pH of a 5% solution is another edge: the free acid is specified at 2.5–4.5, and a reading at the edge should send the laboratory back to the meter, the dilution and the age of the sample before the lot is rejected.

What moves between batches

Water and pH are the first lines to move. The drying step and the final isolation change the water; residual acid or a neutralisation step changes the pH; both can move an as-is assay. Colour and related-substance peaks usually drift more slowly, and a new peak matters more than a small shift in the main peak.

Granulation changes flow and particle size, but the catalog sets no sieve figure. A capsule line that needs a defined particle profile needs a separate specification, not an assumption about the standard powder.

A trend across three or four lots is more informative than one result near an edge: water rising, pH drifting one way, or assay falling as water climbs. Ask for the trend and the retained samples.

When to order an outside test

An outside test is worth ordering for a new source, a disputed form, a first shipment into a regulated market, or a label declaration that the supplier's certificate does not support. The panel should be targeted: HPLC with a UV spectrum, water by Karl Fischer, sodium by ICP-OES for the salt, phosphorus for the nucleotide, the heavy-metal panel, microbiology and residual solvents.

The report should give a detection limit for every screen; “not detected” means little unless the reader knows how low the method can see. Keep the retained sample and the chain of custody, because a disputed result is settled on the sample that both sides hold.

What to compare between suppliers

Compare six lines: the form and its CAS number; the assay and the basis it is reported on; water and pH; the sodium figure where the salt is claimed; heavy metals and microbiology; pack, lot code and retest date. Two certificates can print the same percentage and still describe different materials.

The citicoline product page carries the catalog specification. The tests that separate the two forms are on the identity page; the label consequences are on the citicoline versus Alpha-GPC page; the market documents are on the compliance page. The separation is described in the HPLC method note, and the quality page sets out the release sequence.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation