01 COA & batch testing

What the COA for yeast beta-glucan actually contains

Technical document 01 · Reviewed 2026-11-19 · Beta-Glucan

On this page
  1. The certificate as a test report
  2. The assay basis, moisture and the mass balance
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A yeast β-glucan certificate is readable when every line pairs a test with its procedure and a release limit with the lot's measured value. The β-glucan result should come from a named enzymatic procedure, with moisture, ash and protein reported beside it. The ≥70% value in the catalog is a specification; the COA belongs to one lot and one pack.

In one line

A β-glucan percentage is a method-dependent number: the certificate must name the enzymatic procedure, report moisture and ash on the same page, and show the measured result apart from the release limit.

The certificate as a test report

Start with the identity block: material name, yeast source, CAS 9041-22-9, formula (C6H10O5)n. Then read the test rows. A row is auditable when it states what was run, by which procedure, and against which limit. “Conforms” on its own is a conclusion, and the reader cannot check it.

Release tests for yeast β-1,3/1,6-glucan
TestProcedureLimit
AppearanceVisual examinationOff-white to light brown powder
IdentificationEnzymatic and HPLC comparison with the referenceConforms
β-GlucanEnzymatic assay; kit or enzyme sequence named≥70%
MoistureGravimetric drying≤6.0%
AshResidue after ashing≤3.0%
ProteinNitrogen determination, Kjeldahl or Dumas≤5.0%
Heavy metalsICP-MS, element by elementPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate counts and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The assay basis, moisture and the mass balance

The β-glucan line is not a total-glucose line. The procedure releases glucose from β-linked glucan, measures it, and corrects for the α-glucan fraction obtained in a separate digestion. The certificate should identify the enzyme preparation or kit, because a cereal β-glucan method and a yeast cell-wall method use different enzymes and extraction steps. Without that identification, 70% is a percentage of an undefined measurement.

The basis is the second half of the definition. A result on the powder as received and a result on the dried solids are different figures whenever moisture is present. At 6.0% moisture, 70.0% as-is corresponds to about 74.5% on the dried basis; the same analytical run can be reported either way. The certificate should say which basis was used in the assay row, and the moisture result beside it should let the reader repeat the calculation.

The mass balance is the third check. β-glucan, moisture, ash and protein account for most of the powder, with cell-wall residue, lipid and minor carbohydrate making up the rest. At 70% β-glucan, 6.0% moisture, 3.0% ash and 5.0% protein, about 16% remains for those fractions. A much wider gap is a reason to ask what else is in the powder.

Release limit versus batch result

The limit is a gate; the result is a measurement. A certificate that prints the gate in both columns has reported the specification, not the lot. Each result should carry its unit, and the method should sit next to the figure it produced.

How the result column should differ from the limit
TestLimitResult expected on the COA
β-Glucan≥70% by the named enzymatic methodThe measured percentage, with basis and method
Moisture≤6.0%The measured percentage
Ash≤3.0%The measured percentage
Protein≤5.0%The measured percentage and the nitrogen factor used
Heavy metalsElement-specific limitsOne figure per element, in mg/kg
MicrobiologyCounts and absence statementsThe count and the absence finding for the lot

Microbiology and heavy metals are where summarising does the most damage. A single “heavy metals pass” line hides which element was close to its limit. A microbiological “pass” without the count and the absence finding cannot be compared with the next lot.

What moves between batches

Yeast strain, fermentation time, cell-wall washing, dryer temperature and mill settings all leave a trace on the certificate. The first three move protein, ash and colour; the dryer moves moisture; the mill moves particle size and bulk density without touching the β-glucan content. A specification that folds all five into one “process” cannot explain a shift.

Colour deserves separate attention. Off-white to light brown is broad enough to absorb normal lot-to-lot variation, so a shade change inside the range is not proof of a defect. A powder that turns markedly darker can reflect a hotter dryer, a longer hold or a reaction involving the protein fraction. Re-test moisture and β-glucan before drawing a conclusion from appearance alone.

Look for direction across several lots, not just a single result near an edge. β-glucan that drifts down, protein or ash that climbs, or a new feature in the sugar profile is more informative than one number that barely passes. The lot code should connect the certificate, the pack and the retained sample.

When to order an outside test

An independent laboratory is worth using for a new yeast source, a first shipment to a regulated market, a certificate that does not explain its method, or a result in dispute. The outside panel should add a second view rather than repeat the supplier's sheet: a second enzymatic β-glucan result with the procedure named, moisture, ash and protein, ICP-MS for each metal, microbiology, and an HPLC sugar profile that can reveal a glucose or maltodextrin carrier.

Require a detection limit for every screen. “Not detected” without a limit describes the laboratory's sensitivity, not the absence of the substance. If the source itself is questioned, add a linkage analysis or a microscopy examination; neither is a routine release test, but each answers a question that a percentage cannot.

Traceability runs from the retained sample to the report. The laboratory should receive the sealed retained sample and the lot code, and the report should name both. In a dispute, the referee needs the sample, the supplier's certificate and the agreed specification, and the tests chosen should separate the source or the method rather than repeat the same assay.

What to compare between suppliers

A supplier comparison needs six columns: yeast source and strain; linkage stated as β-1,3/1,6; β-glucan result with method and basis; moisture, ash and protein; heavy metals and microbiology; pack size and lot code. Two certificates that both say 70% but name different methods have not established equivalence.

Traceability is the second layer. The file should identify the manufacturer, the fermentation and cell-wall process, and the drying and milling steps. For the catalog figures, start at the beta-glucan product hub. The structural checks are set out on the identity page; the claim and market questions are on the compliance page; the analytical procedures are described in the methods library; the release steps are on the quality page. The chitosan page is a parallel file for another source-dependent polymer.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation