01 COA & batch testing

What the COA for alpha-lipoic acid actually contains

Technical document 01 · Reviewed 2026-11-19 · Alpha-Lipoic Acid

On this page
  1. The certificate as a test report
  2. Assay, basis and the mass balance
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A certificate for a racemic alpha-lipoic acid lot reports appearance, identification by infrared and HPLC, assay by HPLC at 99.0–101.0%, melting point at 60–62 °C, loss on drying at ≤0.5%, the heavy-metal panel, microbiology and particle size at ≥95% through 40 mesh. The assay and the melting point are the usual identity screen, and neither one separates the racemic grade from the R-form. The limits in the first table are the catalog specification; the result column on a batch certificate is where the measured numbers belong.

In one line

The assay says how much lipoic acid is present, the melting point and the infrared spectrum say which solid it is, and the loss on drying decides how the percentage is read.

The certificate as a test report

A release certificate becomes auditable when every line carries three things: the parameter, the method that produced the number, and the limit the lot was released against. A line that says only “conforms” records a conclusion and withholds the evidence. For this material the identity line should name infrared and HPLC together, because the infrared spectrum carries the carboxyl and disulfide bands and the HPLC retention carries the molecule as a whole.

Identity, assay and release limits · racemic alpha-lipoic acid
ParameterMethodRelease limit
AppearanceVisualYellow crystalline powder
IdentificationInfrared and HPLCConforms to the reference
AssayHPLC99.0–101.0%
Melting pointCapillary method60–62 °C
Loss on dryingGravimetric≤0.5%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 40 mesh

Assay, basis and the mass balance

The catalog range is 99.0–101.0% by HPLC, and the certificate should state the basis the figure is reported on. With loss on drying at ≤0.5%, the gap between the as-is and the dried figure is at most about half a percentage point, which is enough to move a lot across the 99.0% line. A result of 99.0% as-is with 0.5% water calculates to about 99.5% on the dried basis; the same number describes two different powders.

An upper limit above 100% is normal for an assay read against an external reference standard, because the result is a ratio to the standard rather than a mass balance. It is not a licence to accept a result of 103%. The mass-balance evidence sits in the other lines: loss on drying, melting point and the sulfur content, which is 31.1% for the pure molecule.

HPLC supplies the assay and part of the identity, but a single peak at the right retention time can still be another disulfide. Infrared is the second dimension, and the melting point is the third. A certificate that reports a percentage and an appearance but no spectrum and no melting range has not shown the solid.

Release limit versus batch result

The release limit is the boundary; the batch result is the measurement. Both belong on the certificate, in separate columns, with the method beside them. A result column filled with the specification range is not a result, it is a copy of the gate.

What the result column should contain
ParameterRelease limitResult column
Assay99.0–101.0% by HPLCA measured percentage, with the basis
Melting point60–62 °CA measured range, start and end
Loss on drying≤0.5%A measured percentage
Heavy metalsPer elementA figure in mg/kg for each element
Particle size≥95% through 40 meshThe measured percentage through the sieve

“Passes specification” is a conclusion the reader should be able to reach from the page. For heavy metals the evidence is a figure per element, not a single total; a summed figure hides the element that failed.

What moves between batches

Between lots, the assay, the colour, the loss on drying and the sieve result move with the crystallisation, the drying step and the milling. The melting point is the narrowest limit on the sheet and the most informative. Racemic alpha-lipoic acid melts at 60–62 °C as a racemic compound; a lot that melts below the range can carry residual solvent, moisture or an impurity, and it can also be enriched in one enantiomer, because a single enantiomer packs differently and melts at its own temperature. Only a chiral test answers the last question.

Colour is the least quantitative line. Yellow crystalline powder covers a visible range, and a batch that is noticeably darker or browner can point to heat or light exposure during drying while the assay still passes. Ask for the batch record before rejecting on colour alone.

A trend across lots carries more weight than one result near an edge: assay drifting low, loss on drying climbing, or a melting range that is consistently at the bottom of the window. The lot code on the certificate should match the pouch, the drum and the retained sample.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, an optical-form claim the supplier's certificate does not prove, or a disputed result. The useful panel is not a full repeat: HPLC assay and infrared identity, melting point, loss on drying, ICP-MS for the heavy metals, microbiology, and a chiral method if the R-form or the racemic form is being claimed specifically. Elemental sulfur is a useful addition when a dilution is suspected.

Ask the laboratory to report its detection limit for each screen. A “not detected” line without a limit is evidence about the method's sensitivity, not about the sample. The sample tested should be the retained sample, and the report should identify the lot.

What to compare between suppliers

Put six lines side by side when comparing suppliers: optical form and CAS number; assay result and basis; melting point; loss on drying; heavy metals and microbiology; pack size and lot code. Two quotations that agree on assay but differ on form or on basis are not describing the same powder.

The catalog specification is on the product hub. The tests that separate the racemic grade from the R-form are on the identity page; the market file is on the compliance page; the assay method is described in the HPLC method note; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation