What the COA for whey protein hydrolysate actually contains
A certificate for a whey protein hydrolysate carries the composition panel of any whey powder and one parameter that no isolate or concentrate has: the degree of hydrolysis. The protein figure is a Kjeldahl nitrogen result expressed against a dry basis, while the degree of hydrolysis says how much of that protein was cleaved into shorter chains. The catalogue limits are in the tables below; the batch COA confirms the lot being shipped.
A hydrolysate certificate has to carry two figures that define the product: the protein on a named nitrogen factor and dry basis, and the degree of hydrolysis that says how far the breakdown went.
The parameter list
“Whey protein hydrolysate” is a family name. It covers powders from a light partial hydrolysis to a product where most of the protein sits in short peptides; the degree of hydrolysis separates them. The certificate therefore reads as a composition panel plus a process figure, not a single assay.
| Parameter | Method | Catalogue limit |
|---|---|---|
| Appearance | Visual | Off-white to cream powder |
| Identification | Protein profile against a reference | Conforms |
| Protein, dry basis | Kjeldahl, N × 6.38 | ≥80.0% |
| Degree of hydrolysis | OPA or equivalent, named on the certificate | 15.0–25.0% |
| Moisture | Loss on drying | ≤5.0% |
| Fat | Solvent extraction | ≤2.0% |
| Lactose | HPLC | ≤2.0% |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
| Parameter | Method | Catalogue limit |
|---|---|---|
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and pathogen screen | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent |
Three things are deliberately absent from this panel: ash, sodium and the peptide size distribution. Hydrolysis runs at a controlled pH; the acid or alkali used to hold it leaves a mineral residue, so ash and sodium can move without the protein figure moving. They are agreed separately when a formula or a market file needs them. The peptide distribution is the property the degree of hydrolysis only approximates.
Protein basis, nitrogen factor and degree of hydrolysis
The protein figure hides two conversion steps. The first is the nitrogen factor: milk protein is calculated as nitrogen × 6.38, and the same powder read with the general food factor of 6.25 would report 78.4% instead of 80.0%, because 80.0 ÷ 6.38 = 12.5% nitrogen and 12.5 × 6.25 = 78.4%. The second is the moisture basis: 80.0% on a dry basis at the 5.0% moisture limit is 76.0% as the powder is weighed. A certificate that reports a bare percentage has hidden both steps.
The degree of hydrolysis is a different kind of number. It is the share of peptide bonds that the enzyme has cleaved, expressed against the total, and it is measured by a colorimetric or titration method such as OPA, TNBS or pH-stat. Each method gives a slightly different answer on the same lot, so the method should be named. A degree of hydrolysis of 20% means roughly one bond in five has been cut; the protein is not converted into free amino acids, and much of the mass remains in peptides long enough to behave like protein.
The figure is an average. Two lots can both report 20% and still differ in how the peptides are distributed, so a distribution by size-exclusion HPLC or electrophoresis is the second measurement worth asking for. The HPLC method note describes how a size-based separation is set up, and the identity page sets out where the distribution sits in the identity file.
The accepted limit and the measured result
Each line carries two numbers that are not interchangeable: the limit the lot had to meet, and the figure the laboratory actually measured. Print them in separate columns, with the method beside them. A column that repeats the limit is a copy of the specification, not a result.
| Parameter | Accepted limit | What the result states |
|---|---|---|
| Protein | ≥80.0% dry basis, N × 6.38 | A measured percentage with the nitrogen figure and the moisture |
| Degree of hydrolysis | 15.0–25.0% | A measured percentage and the method |
| Moisture | ≤5.0% | A measured percentage |
| Fat and lactose | ≤2.0% each | A measured percentage for each |
| Heavy metals | Per element | A figure in mg/kg for each element, not a total |
| Microbiology | Counts and absence | A plate count plus the absence statement for the lot |
The degree of hydrolysis is often reported as “conforms” with no figure, yet that is the line a buyer most needs: a lot at 16% and a lot at 24% are both inside the window and taste different. Ask for the number and the method, and match them to the sample that was tasted; the grades page explains why the band is wide.
What moves between batches
The enzyme preparation, the hydrolysis time, the temperature and the point of inactivation set the degree of hydrolysis. The neutralisation step sets the ash and the sodium. The dryer sets the moisture, the particle size and the colour, and a long warm hold before drying darkens a powder that still passes every limit.
Bitterness moves with the peptide profile rather than with the protein figure. A change of enzyme or a longer hydrolysis can raise the bitterness while the protein and the moisture stay inside the specification, so a taste check on the retained sample belongs in the change control. Colour is the weakest line: off-white to cream covers a wide band, and a shift inside it is not an identity failure.
Particle size is a finishing specification: a change of mill or sieve changes the result without touching the chemistry, and it changes how the powder flows at a stick-pack filler.
Bringing in a referee laboratory
Commission an outside test when the source is new, when the first shipment enters a regulated market, when the hydrolysate claim is contested, or when a result is disputed. A targeted panel is enough: protein by Kjeldahl, degree of hydrolysis by a named method, peptide distribution by size-exclusion HPLC, lactose and fat, the heavy-metal panel by ICP-MS, microbiology, and a milk-protein check if the allergen declaration is in question.
Ask the laboratory to report its limit of detection for each screen: a “not detected” line without a limit describes the method, not the sample. The laboratory should test the retained sample and name the lot on its report.
Reading two quotations side by side
Line up six items: the protein result with its nitrogen factor and basis; the degree of hydrolysis with its method; the peptide distribution; fat, lactose and moisture; the allergen and origin statements; and the pack size with the lot code. Two quotations that agree on protein but differ on the hydrolysis method are not offering the same powder.
The catalogue specification sits on the product page. The comparison with the isolate covers taste and the label; the release file is described on the quality page; the methods index lists the test notes behind these lines.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation