01 COA & batch testing

What a sodium selenite COA has to show

Technical document 01 · Reviewed 2026-11-19 · Sodium Selenite

On this page
  1. The certificate as a test report
  2. Assay, selenium figure and the water that separates them
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for a sodium selenite lot reports appearance, identification by infrared and titration, assay by iodometric titration, the selenium figure from the same titration chemistry, loss on drying, the heavy-metal panel and microbiology. The assay and the selenium figure are not independent measurements, so the certificate is only readable when the method, the basis and the water content sit beside them. The limits below are the catalog specification; the batch COA is the document for a particular pack.

In one line

The assay, the selenium figure and the loss on drying are one calculation: a selenite result is only readable when the titration, the 44.0–46.0% selenium range and the water content are shown together.

The certificate as a test report

A certificate earns its place when a reviewer can check each line without a follow-up question. Every parameter should show what was measured, the method, the release limit and the result for the lot. “Conforms” is a conclusion; the evidence is the method and the figure.

The release panel is short. The assay is an iodometric titration: selenite oxidises iodide to iodine in acid, and the iodine is titrated with sodium thiosulfate. The selenium figure comes from the same redox chemistry through the stoichiometric factor; infrared identification confirms the salt. Moisture, metals and microbiology complete the panel.

Identity, assay, moisture and contaminants · sodium selenite
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationInfrared and titrationConforms to the reference
AssayIodometric titration98.0–101.0%
SeleniumIodometric titration, reported as Se44.0–46.0%
Loss on dryingGravimetric≤2.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The table is a specification, not a batch record. A lot certificate repeats the lines with measured results, a lot code and a release date.

Assay, selenium figure and the water that separates them

Anhydrous sodium selenite is 45.66% selenium by mass, so a 99.0% assay corresponds to about 45.2% selenium on the same basis. The selenium row is therefore not a second opinion on purity; it is the same titration expressed as the element. An assay and a selenium figure that do not move together point to a basis problem, an arithmetic error or an impurity.

The basis is often missing. A result on the dried basis is higher than the same lot reported as-is, because the water has been divided out. At 2.0% loss on drying, a 45.2% dried-basis selenium figure becomes about 44.3% as-is. The certificate should state the basis in the assay row and give the loss on drying as a measured figure, not only a limit.

The catalog article is the anhydrous salt, CAS 10102-18-8; the pentahydrate, CAS 26970-82-1, carries about 30.0% selenium and about 34% water and cannot meet a 44.0–46.0% selenium range or a ≤2.0% loss on drying. A certificate that does not name the hydrate leaves the reader to infer it from the numbers.

Release limit versus batch result

The release limit is the acceptance boundary. The batch result is what the laboratory measured on that lot. Both belong on the page, in separate columns, with the method beside them. A result column filled with the specification range is a copy of the gate, not a result.

What the result column should contain
ParameterRelease limitResult column
Assay98.0–101.0%A measured percentage, with the basis and the method
Selenium44.0–46.0%A measured percentage, with the same basis
Loss on drying≤2.0%A measured percentage
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot

“Passes specification” is a conclusion the reader should be able to reach from the figures. For microbiology the evidence is a count plus an absence statement; for heavy metals it is a figure per element, not a single total. A certificate that reports a sum of heavy metals has hidden the element that matters. Arsenic deserves its own line and detection limit, because the catalog limit is 2 mg/kg and a total-arsenic method says nothing about the species.

What moves between batches

Moisture is the largest mover. The powder is hygroscopic; a lot at 0.8% loss on drying and a lot at 1.9% can both pass, but they behave differently once the pouch is opened. The as-is assay moves with the water content, and the selenium figure follows.

The titration moves by tenths of a percent with the standard, the end point and the analyst. That is method variation, not a quality signal; the certificate should still state the method and the basis.

Appearance is the qualitative line. White to off-white is the catalog description; a pink or red tint suggests some selenite has been reduced to elemental selenium, and a damp or caked powder suggests moisture pickup. Neither is an identity failure on its own, but both deserve a retained sample and a re-test before release. Granulation can change bulk density and flow without moving the assay, so record the presentation and compare like with like.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, a hydrate that the certificate does not name, or a result the buyer disputes. The useful panel is not a repeat of the certificate: total selenium by ICP-MS, ion chromatography for selenite and selenate, sodium by ICP-OES, loss on drying, the metal panel and microbiology. Add X-ray diffraction if the hydrate or the crystallinity is in question.

The titration measures selenite, not total selenium. That selectivity is useful. If the ICP-MS total selenium is higher than the titration-derived figure, another selenium species is present, most likely selenate. If the total is lower, the digestion or the calibration is suspect. Ask for the detection limit and the recovery beside each result; a “not detected” line without a limit describes the method, not the sample.

Chain of custody should connect the sample, the retained portion and the lot code. A report that names the product but not the lot is a demonstration of method, not evidence about the delivery.

What to compare between suppliers

Put six lines side by side: form and hydrate; CAS number; assay with its basis; selenium figure with its basis; loss on drying; metals and microbiology. Two quotations that agree on assay but differ on hydrate or basis are not describing the same powder. A quotation that names only “sodium selenite” leaves the hydrate and the basis open.

The second layer is the document trail: who manufactured the lot, and whether the certificate, the specification and the pack carry the same revision and lot code. The catalog specification sits on the sodium selenite product page. The tests that separate the hydrate and the oxidation state are on the identity page; the destination file is on the compliance page; the titration and ICP-MS methods are described in the methods library; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation