What a potassium gluconate COA reports, and on what basis
Potassium gluconate arrives with two potency numbers, and they answer different questions. The assay measures the salt; the potassium line measures the element. A certificate that prints both, with the water result and the method beside them, lets a buyer set a fill weight without guessing. The limits below are the catalog specification, and the lot sheet is what turns them into a batch record.
Two numbers carry the certificate: the salt assay by titration and the potassium figure beside it, and neither is usable until the basis and the water result are stated.
Reading the certificate row by row
Three identity signals belong on the sheet: an infrared spectrum, a titration and the potassium figure. The first two establish the gluconate; the third establishes the cation. A certificate that lists only “identity: conforms” has compressed three answers into one word.
The potency pair is what buyers read first, but the water line is what makes the pair usable. Potassium gluconate is anhydrous and the water limit is 1.0%, so a lot near the limit can lose a full point of as-received assay before anything else changes. The table sets out the gate.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White crystalline powder |
| Identification | Infrared and titration | Conforms to the reference |
| Assay (potassium gluconate) | Titration | 99.0–101.0% |
| Potassium (K) | Titration | 16.0–17.0% |
| Loss on drying | Gravimetric | ≤1.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeasts and moulds ≤100 cfu/g; E. coli absent; Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
Which basis, and why the two figures differ
The assay is a titration of the gluconate and is expressed as potassium gluconate. The potassium line is an element figure. The bridge between them is stoichiometry: C6H11KO7 has a molecular weight of 234.25, potassium is 39.10, and 39.10 ÷ 234.25 gives 16.69%. That is the potassium content of a theoretical 100% salt.
Multiply the assay by 16.69% and the expected potassium follows. The catalog assay window of 99.0–101.0% maps to 16.52–16.86% potassium, which is narrower than the 16.0–17.0% potassium window on the sheet. The wider window is there to absorb titration variability, not to describe a second grade.
Basis is the second trap. A result calculated on the dried weight and a result calculated as received are not the same number when water is present. With a 1.0% water limit the difference can reach one percentage point, enough to move a lot from the middle of the assay range to its edge. The certificate should name the basis in the row, and the buyer should ask for the as-received figure because that is what the scale weighs.
Gate, result and the words in between
A specification is a set of limits; a certificate is a set of measurements against them. When the result column contains the same range as the limit column, the document has not recorded a measurement. The three-column layout below is the minimum that can be checked.
| Parameter | Release limit | Result column |
|---|---|---|
| Assay | 99.0–101.0% | A measured percentage, with the basis stated |
| Potassium | 16.0–17.0% | A measured percentage and the method |
| Loss on drying | ≤1.0% | A measured percentage |
| Heavy metals | Per element | A figure in mg/kg for each element, not one total |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
Identity can reasonably be reported as “conforms” if the spectra and titrations are on file. Assay, potassium and water should be numbers. For the heavy metals, a result per element is required; a single sum cannot be compared with a destination limit. Microbiology needs both a count and an absence statement.
Where lots actually differ
The potassium figure is fixed by the formula, so it should not wander much between lots. Water, mesh, colour and trace metals are the lines that move, and they move for process reasons: crystallisation conditions, drying time, mill settings and the cleanliness of the line.
Water is the first to watch. A lot released at 0.9% has very little room in a humid warehouse, while a lot at 0.2% can absorb some moisture before it reaches the gate. Neither is out of specification at release; they age differently.
Appearance is the least specific line: white to off-white covers a broad range, so a shade difference alone should not be read as an identity result. A grey or yellow cast, or hard caking in the liner, is worth an investigation, but a slight change of tint is not. Mesh is a finishing variable: a 40 mesh result can change with a new screen without any change to the salt.
When the supplier's sheet is not enough
Independent testing earns its cost in four situations: a new source, a first shipment to a regulated market, a label dispute, or a potassium result that does not fit the assay. The panel can be short — FTIR, titration for assay and potassium, water, ICP-MS for the contaminant panel, and microbiology. Add sodium when sodium gluconate is a possibility, and chloride when potassium chloride is one.
Ask each laboratory for its limit of detection. “Not detected” without a limit says something about the method, not about the powder. Ask, too, for the lot code on the report; a result that cannot be tied to the retained sample is difficult to use in a dispute.
If a result is contested, send the retained sample, the supplier's certificate and the agreed specification to the referee. The useful instruction is to run the test that separates the suspected substitution, not to repeat the assay that both sides already have.
Six lines for a supplier comparison
Compare the salt and CAS number, the assay with its basis, the potassium figure, the water result, the contaminant and microbiology panel, and the pack with its lot code. Two sheets can agree on assay and disagree on potassium or basis, which means they do not describe the same powder.
The second layer is provenance: the manufacturer, the process and the pack, with a lot code that matches pouch, drum and retained sample. Catalog limits are published on the product hub; the tests that distinguish the salt from a substitute are on the identity page; the market route is on the compliance page; the heavy-metal method is in the ICP-MS note; release is described on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation