What the COA for ferrous bisglycinate actually contains
The certificate for a ferrous bisglycinate lot reports appearance, identification by IR and HPLC, assay by HPLC, elemental iron by complexometric titration, moisture, the contaminant panel, microbiology and a sieve result. The assay and the iron figure are two views of the same chelate, and the certificate is complete only when the glycine ratio and the moisture sit beside them. The limits below are the catalog specification; the lot certificate is what proves the pack in hand.
The assay and the iron figure describe the same chelate from two directions, and the glycine ratio and moisture are what make the pair add up.
Reading the certificate as a test report
A certificate can be audited only when each row states what was measured, the method and the limit. A row that says “conforms” without a method leaves the reader with a conclusion and no evidence. The two quantitative lines on this sheet are not duplicates: the HPLC assay measures the chelate, and the titration measures the element.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Greenish-grey to off-white powder |
| Identification | IR and HPLC | Conforms to the reference |
| Assay | HPLC | 98.0–102.0% |
| Iron (Fe) | Complexometric titration | 26.0–28.0% |
| Glycine ratio | HPLC | 2:1 molar; report the measured ratio |
| Loss on drying | Gravimetric | ≤5.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
The glycine ratio is the line that shows the stoichiometry rather than the total. A certificate that prints assay and iron but no ratio has shown two totals; it has not shown that the glycine is bound to the iron at the 2:1 ratio the name implies.
Assay, iron and moisture are one calculation
The chelate is Fe(C2H4NO2)2, formula C4H8FeN2O4 and molecular weight about 203.96. At full stoichiometry it carries 27.38% iron and 73.61% glycine on a free-glycine basis. The catalog window of 26.0–28.0% iron brackets that theoretical figure, which is why the iron line is a real identity check and not a second assay.
The basis matters because the three lines multiply. Take a lot at 98.0% assay on the dried basis with 5.0% loss on drying: as weighed, the chelate is 93.1% of the powder and the iron is 0.980 × 0.950 × 27.38% = 25.5%, below the 26.0% floor. The same numbers on a different basis can pass. The basis belongs beside the assay value, with the measured loss on drying next to it, not at the foot of the page.
Read the trio together. If assay, iron and moisture do not close the arithmetic, ask which basis was used before disputing the result. A lot can meet the assay and fail the iron because of moisture alone, and no chemistry has changed in the drum.
Release limit versus batch result
One column states the gate the lot had to meet; the other states what the laboratory actually found. Both belong on the certificate, with the method named beside them. If the result column repeats the specification range, the reader is looking at the gate again, not at a measurement.
| Parameter | Release limit | What the result should show |
|---|---|---|
| Assay | 98.0–102.0% | A measured percentage, with the basis and the HPLC method |
| Iron | 26.0–28.0% | A measured percentage by titration, with the calculation |
| Loss on drying | ≤5.0% | A measured percentage |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
“Passes specification” is a conclusion the reader should be able to reach from the numbers. A single total for heavy metals hides the individual element that matters. A microbiology line without the count is an opinion, not a measurement.
What moves between batches
Colour is the least numerical line on the sheet, and it often says the most. Greenish-grey to off-white covers a wide window; a browner or darker lot can point to oxidation of ferrous iron to ferric, a longer hold or a different drying step even though the assay passes. Request the ferrous/ferric ratio rather than rejecting on colour alone.
The iron figure by complexometric titration measures total iron, so a partly oxidised lot can still titrate inside the window. That is why the valence check sits behind the certificate: the element has not left, but its oxidation state has changed. Loss on drying moves with the pack and the warehouse, and the glycine ratio moves with the reaction and the recovery step.
Particle size is a finishing line. A change of mill or sieve moves the 40 mesh result without any change in the chemistry, and the lot code should link the pack, the certificate and the sample kept for reference.
When to order an outside test
An outside test earns its cost at a new source, a first shipment, an unproven form claim or a contested result. The useful panel is targeted: complexometric titration for iron, HPLC for the glycine ratio, IR for identity, a ferrous/ferric check, sulfate, fumarate and gluconate screens to exclude an iron salt blend, ICP-MS for the heavy-metal panel and a moisture determination.
Add XRD when the question is whether the solid is a crystalline chelate or an amorphous dilution. Have the laboratory state the detection limit behind every screen; “not detected” without a limit describes the method, not the sample. Keep the chain of custody intact: the material in the laboratory should be the material held in retention.
What to compare between suppliers
Six lines are enough to compare two suppliers: the form and CAS; the assay and its basis; iron and method; glycine ratio; moisture; and the contaminant and microbiology results with the pack size and lot code. If two offers match on assay but not on basis or ratio, they do not describe the same powder.
The second layer is traceability: who made the lot, which iron source and which glycine went into it, and how it was dried and milled. The catalog specification is published on the iron bisglycinate product page. The form and grade questions are on the grade comparison page; the tests that prove the chelate are on the identity page; the analytical method is described in the methods library; how lots are released is described under quality.