The catalog grade is a 40-mesh ferrous bisglycinate powder specified at 26.0–28.0% iron; granulation is available on request and changes flow and dust, not the chelate. A material sold below that iron window is a diluted or lower-strength grade, and it needs its own specification and label. The 2:1 glycine–iron ratio is the identity that stays the same across every grade.
The grade changes the powder, not the chelate: mesh, flow and iron per gram move while the 2:1 glycine–iron identity stays.
Why a chelate still has grades
In this catalog, grade means physical form and concentration, not a different iron compound. The chemistry is fixed: one ferrous ion bound to two glycinate ligands. What a buyer can choose is particle size, flow behaviour and the iron figure per gram of powder.
The standard is a 40-mesh powder. A granulated version is for flow and dust control. A diluted version lowers the iron per gram for a small-dose formula. Each is a separate specification with its own fill weight and, in the diluted case, its own ingredient list. None of them is a different chelate.
The grades side by side
| Grade | Iron | What changes | Typical fit |
|---|---|---|---|
| 40-mesh powder (catalog) | 26.0–28.0% | Standard particle size and flow; dissolves in water | Capsules, tablets, powder blends |
| Granulated, on request | 26.0–28.0% | Larger particles, less dust, better flow, slower wetting | High-speed tableting, dry blends |
| Carrier-diluted, separate purchase | Below the catalog window | Carrier mass, assay basis and label | Small-dose premix |
| Blend offered as bisglycinate | Variable | Not a grade; the chelate is not proved | Not supplied under this specification |
The last two rows are the ones that catch buyers. A diluted grade is a legitimate purchase when the carrier is declared and the assay is quoted on a stated basis, but it is not the 26.0–28.0% material. A blend of an iron salt and glycine can look like a chelate on a certificate that reports only iron and nitrogen; the sulfate screen, the valence check and the solid-state pattern are what expose it.
Mesh, flow and the solution
The catalog particle size is ≥95% through 40 mesh. That is a sieve result, not a promise about every particle: the certificate should report the measured percentage through the sieve. Granulation builds larger particles from the same powder. It raises bulk density, cuts dust and segregation, and can slow the rate at which the powder wets and dissolves.
Ferrous bisglycinate is soluble in water and the solution is acidic. In a capsule or a tablet the powder is swallowed, so dissolution in the glass is not the question; in a stick pack or a drink mix it is. A granulated grade that flows well on a tableting press may sit longer in a glass of water, and the two effects come from the same change in particle size.
Colour is greenish-grey to off-white in every grade. A granulated lot and a milled lot can differ slightly in shade without a chemistry change, but a brown cast is an oxidation signal and not a grade difference.
Matching the grade to the dosage form
| Dosage form | Starting grade | What to check |
|---|---|---|
| Capsule | 40-mesh powder | Fill weight from elemental iron; flow on the encapsulator |
| Tablet | Granulated, on request | Flow, compaction and the dissolution result |
| Stick pack or drink mix | 40-mesh powder | Wetting, colour and taste in the finished mix |
| Dry blend or premix | Granulated or powder | Segregation and the carrier declaration |
The fill weight follows the iron figure, not the chelate mass. At the 27.0% midpoint, a 20 mg iron dose takes 20 ÷ 0.27 = 74 mg of powder; at 26.0% it takes 77 mg, and at 28.0% it takes 71 mg. A granulated grade keeps the same arithmetic. A diluted grade does not, because the iron figure has moved.
What to write into the specification
- “Ferrous bisglycinate, CAS 20150-34-9, C4H8FeN2O4, 2:1 glycine–iron chelate.”
- “Assay 98.0–102.0% by HPLC; iron 26.0–28.0% by complexometric titration.”
- “Glycine ratio 2:1 molar; report the measured ratio on the certificate.”
- “Loss on drying ≤5.0%; particle size ≥95% through 40 mesh.”
- “Granulation or carrier, if any, named with the carrier identity and the assay basis.”
- “Label name: ferrous bisglycinate, written out rather than a generic ‘iron chelate’.”
A purchase order that says “chelated iron” has not specified this material. The form name, the ratio and the iron window are what make the order reproducible.
When a different grade is the wrong answer
If the label declares ferrous bisglycinate as the ingredient, a carrier-diluted grade adds an ingredient the label does not name, and the declaration has to change. If the product is a stick pack that must dissolve quickly, a granulated grade can slow the step it was meant to improve. If the press runs at speed and the powder flows poorly, the un-granulated grade may be the wrong starting point.
The reverse mistakes are just as common. A buyer who needs the 26.0–28.0% material should not accept a 20% grade and adjust the fill weight without a new specification, because the carrier, the assay basis and the label all change with the dilution. A blend is not a grade at all; it is a different material with an unproven chelate.
The catalog specification is on the product page; the release lines are on the COA page; the ratio test is on the identity page; the comparison with a ferrous salt is on the bisglycinate vs fumarate page; the pack and lead time are on the MOQ page.
In this document
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation