Copper gluconate grades: mesh, flow and the fill
Copper gluconate is supplied as a blue-green powder, typically ≥95% through 40 mesh, with a granulated form available on request. The grade decision is physical — particle size, flow and blend behaviour — because the copper figure is fixed by the salt at about 14.0%. A product that changes that copper figure is not another grade of the same salt; it is a different material or a dilution.
The grade of copper gluconate is a physical decision — mesh, flow and blendability — because the copper figure is set by the salt at about 14%.
Three meanings of “grade”
Buyers use the word grade for three different things: a particle size, an assay level, and a chemical form. For copper gluconate the catalog material is one chemical entity, C12H22CuO14, CAS 527-09-3, with copper at 13.5–14.5%. The variables that can be changed without changing the molecule are the mesh, the flow and the carrier.
Copper bisglycinate is not a grade of copper gluconate. It is a different molecule with a different CAS number, copper figure and label name. The comparison belongs on the level-four page, not in a particle-size table.
A diluted blend is a third case. If copper gluconate is plated onto a carrier to make a low-dose premix, the copper figure falls in proportion to the dilution, the carrier must be declared, and the specification is no longer the catalog one. That is a project-specific material, not a grade.
The catalog form and its neighbours
| Material | Copper figure | Flow and dust | Typical use | What changes |
|---|---|---|---|---|
| Catalog powder, 40 mesh | 13.5–14.5% | Free-flowing; some dust | Capsules, tablets, powder blends | The baseline specification |
| Granulated powder | 13.5–14.5% | Coarser; less dust | High-speed blending, tableting | Mesh, flow and dissolution rate |
| Diluted blend, project-specific | Lower, by calculation | Carrier-dependent | Low-dose premix | Carrier, label, assay and dose |
| Copper bisglycinate, different form | About 30.0%, calculated | Chelate powder | Dry blends | Identity, CAS, label and fill |
The first two rows are the catalog form and its granulated option. The third is a different specification that should be quoted and labelled as such. The fourth is not a grade at all; it is a separate ingredient with its own certificate.
Mesh, flow and the process
40 mesh is about 420 µm, and the catalog requires at least 95% through that sieve. A finer powder dissolves and disperses faster, but it generates dust and can segregate in a blend. A granule flows better, fills a tablet die more evenly and produces less dust, but it may dissolve more slowly. The right choice depends on the process, not on a preference for coarse or fine.
Copper gluconate is hygroscopic. A powder stored in an open container can cake and change colour, and a granulated product can lose its flow if it picks up water. Pack and storage are part of the grade in practice, even when the mesh line does not say so.
Bulk density and flow are not in the catalog specification. If the process needs a target, ask for it to be measured and written into the purchase specification. A mesh figure alone does not describe how a powder will run on a particular line.
The copper figure and the fill
Copper is declared in milligrams, and the salt mass is the internal number. At the theoretical 14.0%, 1 mg of copper needs 7.14 mg of copper gluconate; 2 mg needs 14.3 mg; 3 mg needs 21.4 mg. At the bottom of the catalog range, 13.5%, the same 2 mg claim needs 14.8 mg, and at 14.5% it needs 13.8 mg.
| Label claim (Cu) | At 13.5% Cu | At 14.0% Cu | At 14.5% Cu |
|---|---|---|---|
| 1 mg | 7.41 mg | 7.14 mg | 6.90 mg |
| 2 mg | 14.8 mg | 14.3 mg | 13.8 mg |
| 3 mg | 22.2 mg | 21.4 mg | 20.7 mg |
A 2 mg claim uses about 14 mg of salt in a capsule that may weigh 300–500 mg. The salt is a small part of the fill, so the practical problem is uniformity, not capacity: the powder has to be diluted into a premix that can be weighed and blended evenly. A tablet at the same claim needs a comparable premix and a granule that compresses without segregation.
The table is arithmetic, not a dosing instruction. The label claim belongs to the brand and its regulatory reviewer. Granulation does not change the copper figure; it changes how the powder moves, and a granulated grade still needs the same 7.14 mg per milligram of copper.
What to write into the specification
- “Copper gluconate, CAS 527-09-3, C12H22CuO14, copper 13.5–14.5%.”
- “Assay 98.0–102.0% by EDTA titration; state the basis.”
- “Water ≤1.0% by Karl Fischer; appearance blue-green and free-flowing.”
- “Identification by infrared spectrum against a reference and by titration.”
- “Particle size ≥95% through 40 mesh; a granulated grade with its own mesh and flow target.”
- “Heavy metals and microbiology as listed; pack, lot code and destination market.”
A granulated grade needs its own mesh and flow lines in the specification. A diluted blend needs the carrier, the copper figure and the label name; it is not covered by the catalog specification. Write the grade and the form into the purchase order, not only the product name.
When a different grade is the wrong choice
Granulation is the wrong choice when the process needs fast dissolution or a suspendible powder; a granule can take longer to dissolve and may leave a gritty texture. It is also the wrong choice when the existing powder already flows well enough and the change would force a new specification for no process gain.
Do not use a diluted blend when the label names copper gluconate and the carrier is undeclared. The label ingredient is the salt, and a carrier is a separate ingredient with its own declaration. Do not order copper gluconate as a substitute for copper bisglycinate: the copper figure is about half, so an equal weight delivers less copper, and the label name is different. The level-four comparison covers that switch.
The product hub has the catalog specification. The identity page shows how the salt is proved; the COA page shows how the figures are reported; zinc gluconate and manganese gluconate show the same gluconate arithmetic with a different metal; the methods library covers the titration and the sieve test; the quality page covers release.
In this document
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation