06 Identity & adulteration

How to prove a copper bisglycinate lot is the chelate

Technical document 06 · Reviewed 2026-11-19 · Copper Bisglycinate

On this page
  1. The identity layers
  2. The copper ratio: 30% is the fingerprint
  3. X-ray diffraction: the solid-state check
  4. What adulteration looks like
  5. How to write the identity into the specification
  6. Five questions for the supplier

A copper bisglycinate lot is the named chelate when the document, the infrared spectrum, the HPLC assay and the copper titration agree. The formula C4H8CuN2O4 fixes copper at 30.0% and the two glycine ligands at about 70%, so a copper figure near 30% is a direct check on the form. The assay alone cannot separate the chelate from a blend, and the copper alone cannot separate it from another copper salt.

In one line

Identity is the agreement of three measurements: the infrared spectrum shows the glycine–copper bonds, the copper figure lands near 30%, and the mass balance closes with moisture.

The identity layers

A certificate can name the right material and still fail to prove it. Each layer below answers a separate question, and each needs its own evidence. A supplier who answers only the first has described the paperwork, not the powder.

Layers of copper bisglycinate identity
LayerQuestionTestWhat it proves
DocumentIs the chelate named?Name, CAS number, formulaPaperwork only
InfraredIs glycine coordinated to copper?FTIR against a referenceThe chelate, not a blend
ChromatographyIs the peak the chelate?HPLC retention and assayThe molecule and its quantity
CopperIs the metal figure right?Complexometric titrationThe copper content
Mass balanceIs it diluted or wet?Assay, copper, loss on dryingConsistency of the numbers
Solid stateIs it the expected crystal form?X-ray diffractionThe solid form, not the purity

The copper ratio: 30% is the fingerprint

The anhydrous formula gives 63.55 ÷ 211.66 = 30.0% copper, with the two glycine ligands making up the rest. The molar ratio is one copper to two glycines. A result near 30.0% with an assay of 98.0–102.0% is consistent with the chelate; a figure well below 30% points to free glycine, a diluent or a different complex, and a figure well above 30% points to a copper salt or oxide with a higher metal content.

The catalogue range is 29.0–31.0% copper, and that window is narrow enough to catch a gross blend. Adding 5% free glycine to the chelate lowers the copper figure to about 28.5%, below the range. Adding 5% copper sulfate pentahydrate, at about 25.4% copper, leaves the blend near 29.8% and inside the range; the sulfate and the infrared spectrum are then the lines that catch it. A blend can be built to pass one number, which is why the layers are read together.

The mass balance is the third check. A powder with 4.0% loss on drying and a 29.5% as-is copper result carries about 30.7% copper on a dried basis, above the formula figure. That does not prove adulteration, but it does mean the moisture and the copper have to be explained together. The certificate should give the loss on drying beside the assay and the copper, not on a separate page.

X-ray diffraction: the solid-state check

X-ray diffraction answers a different question: is the solid crystalline, and does its pattern match a reference? Copper bisglycinate can exist in more than one solid form, and a hydrate, a different polymorph or an amorphous carrier will not give the same pattern. XRD can also compare lots from two sources when the chemical tests agree but the powders behave differently in a blend.

It is not a purity assay and does not measure the counter-ion. Ask for the reference pattern, the sample preparation and the detection limit before reading a “match” statement. A certificate that reports only “XRD conforms” without the pattern has added little. The method is most useful when the question is solid form, tablet behaviour or the difference between a crystalline chelate and a carrier-based premix.

What adulteration looks like

Substitutions and the signals for copper bisglycinate
AdulterantWhat it doesSignalTest
Free glycineLowers copper; raises the ligand fractionCopper below 29%; IR shows free glycineCopper titration, FTIR, amino-acid analysis
Copper sulfateRaises copper; adds sulfateSulfate present; IR differsSulfate test, FTIR, ICP-OES
Copper oxideRaises copper sharply; insoluble black solidCopper above 31%; black particlesCopper titration, XRD, visual
Copper gluconateLowers copper to about 14%Copper far below range; gluconate IRCopper titration, FTIR
Inert diluentLowers assay and copper togetherBoth low; ash or residueAssay, copper, mass balance
MoistureRaises loss on drying; lowers as-is assayLOD high; dried assay normalLoss on drying
DyeMatches blue colour without copperColour without a copper figureCopper titration, FTIR

Colour is the weakest signal. Blue covers a wide range, and a dye can reproduce it. The stronger signals are the copper figure, the infrared spectrum and the mass balance. A certificate that reports appearance and assay but not identity has left the most likely substitution untested.

How to write the identity into the specification

  • “Copper bisglycinate, CAS 13479-54-4, C4H8CuN2O4.”
  • “Assay 98.0–102.0% by HPLC; state the basis.”
  • “Copper 29.0–31.0% by complexometric titration.”
  • “Identification by infrared spectrum against a reference and by HPLC retention.”
  • “Loss on drying ≤5.0%; particle size ≥95% through 40 mesh.”
  • “No free glycine, copper sulfate or other copper salt above the agreed limit.”
  • “Destination market and form confirmed before the order.”

Five questions for the supplier

  1. Which chelate is this lot, and which CAS number is on the certificate?
  2. Can you provide the infrared spectrum and the HPLC chromatogram, not only the assay percentage?
  3. What is the copper result, by which titration method, and on which basis?
  4. What is the loss on drying for this lot, and how does the copper figure close the mass balance?
  5. If the lot is disputed, will you accept a joint re-test on the retained sample?

The five answers above are what makes an identity file; a lone assay figure is not enough. The hub carries the catalog specification, the COA page maps the certificate lines, the grades page compares the physical forms, the copper gluconate page covers the other copper source, the methods library explains the tests, and the quality page describes release.