01 COA & batch testing

What the COA for copper bisglycinate actually contains

Technical document 01 · Reviewed 2026-11-19 · Copper Bisglycinate

On this page
  1. The certificate as a test report
  2. Two figures, one molecule, and the basis they share
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

Two laboratory results carry a copper bisglycinate lot: the HPLC assay of the chelate and the titration of elemental copper. Read with the infrared identity and the loss on drying, they show whether the powder is the 1:2 copper–glycine complex or something that merely contains copper. The limits below are the catalog target; each delivery is judged on its own certificate.

In one line

The chelate is released on two numbers that must agree: the HPLC assay and the elemental copper, with the glycine identity and the moisture beside them.

The certificate as a test report

A buyer should be able to reconstruct the release decision from the certificate without calling the supplier. That requires a test name, a method and an acceptance limit for every line, plus the measured value for the lot. Vague conformity statements hide which of those three is missing.

Chemistry and physical release lines · copper bisglycinate
TestMethodAcceptance limit
AppearanceVisualBlue, free-flowing powder
IdentificationFTIR and HPLC retentionMatches the reference
AssayHPLC98.0–102.0%
CopperComplexometric titration29.0–31.0%
Loss on dryingGravimetric≤5.0%
Particle sizeSieve analysis≥95% through 40 mesh
Elemental and microbiological limits · copper bisglycinate
TestMethodAcceptance limit
LeadICP-MS≤3 mg/kg
ArsenicICP-MS≤2 mg/kg
CadmiumICP-MS≤1 mg/kg
MercuryICP-MS≤0.1 mg/kg
Aerobic plate countPlate count≤1,000 cfu/g
Yeast and mouldPlate count≤100 cfu/g
E. coliAbsence testAbsent
SalmonellaAbsence testAbsent

Two figures, one molecule, and the basis they share

An assay result is a statement about the molecule; a copper result is a statement about the metal. The formula fixes the relationship between them: C4H8CuN2O4 has a molar mass of 211.66, of which 63.55 is copper, so the calculated metal content is 30.0%. The two glycine ligands account for the other 70.0%. If the assay is 98.0%, the matching copper figure is about 29.4%; at 102.0% it is about 30.6%.

Basis matters as much as the number. A certificate that reports copper as-is, with 5.0% moisture, implies 30.5% on a dried basis, which is higher than the formula allows; the same powder at 1.0% moisture implies 29.3% and is consistent. The certificate should therefore give the basis and the loss on drying in the same block, so the reader can repeat that calculation.

Infrared identity is the third leg. When glycine binds copper, the carboxylate and N–H absorptions move; the resulting spectrum is not a superposition of glycine and a copper salt. HPLC retention then confirms the peak. A blend can be built to pass the assay or the copper line, but it is much harder to reproduce the coordinated spectrum as well.

Release limit versus batch result

An acceptance limit and a measured result are different pieces of information. The first defines the gate; the second describes the lot. A certificate that prints the specification range in both columns has not told the reader what the batch did.

What the lot result should state for each line
LineAcceptance boundaryWhat the batch result should show
Assay98.0–102.0%A measured value, the basis and the HPLC method
Copper29.0–31.0%A measured value and the titration method
Moisture≤5.0%A measured loss on drying
IdentityFTIR and HPLC matchThe spectrum and retention, or conformity to a named reference
MetalsPer elementA separate figure for each element, not a total
MicrobiologyCounts and absenceCounts plus the absence statement
Mesh≥95% through 40 meshThe measured percentage passing the sieve

Two derived checks are worth making. Divide copper by assay: a pure chelate gives about 0.30. A result of 29.0% copper against a 102.0% assay gives 0.284, and 31.0% against 98.0% gives 0.316; both deserve an explanation. Then compare the loss on drying with the copper basis. Moisture can explain part of a low as-is figure, but it cannot explain a metal content above the formula value.

What moves between batches

Different unit operations leave different fingerprints on the certificate. Drying changes the loss on drying; milling and sieving change the particle-size result; crystallisation and drying move both the assay and the copper. Colour follows particle size, hydration and surface oxidation.

Blue is a broad description. A paler shade may mean a finer powder or a diluted lot; a green tinge may mean a different copper species or moisture. Appearance is a prompt to investigate, not a release test, so the spectrum and the metal figure should decide.

Look at the direction of travel across lots. Copper falling while moisture rises suggests a wet powder; copper and assay moving in opposite directions suggests a blend or a different source. Match the certificate's lot code to the pouch, drum and retained sample before accepting the story.

When to order an outside test

Outside testing is worth buying when the source is new, the market is regulated, the certificate is disputed, or the label depends on the chelate identity. A referee panel should answer the identity question, not simply repeat the supplier's assay: FTIR against a reference, HPLC assay, copper by ICP-OES, loss on drying, ICP-MS metals, microbiology and sieve.

If a blend is suspected, add glycine by amino-acid analysis or ion chromatography. If solid form matters, add XRD. Every screen should come with a detection limit; otherwise a “not detected” result says more about the method than the material.

Keep the chain of custody intact. The retained sample is the one to test, the report should name the lot, and a dispute should be settled on the sample both sides hold. Ask the referee to run the tests that discriminate between the chelate, free glycine and a copper salt.

What to compare between suppliers

When two suppliers are compared, place the following lines side by side: identity (form and CAS); assay and its basis; copper and its method; FTIR and HPLC evidence; loss on drying; the contaminant panel; the pack and the lot code. A match on assay alone is not a match on material.

The catalog specification sits on the copper bisglycinate product page. How the chelate is proved is set out on the identity page; mesh and dilution on the grades page; moisture and pack behaviour on the stability page; the test methods in the methods library; the release sequence on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation