Copper bisglycinate grades: chelate, mesh and the fill
Copper bisglycinate reaches the buyer as one chemical entity — the 1:2 copper–glycine chelate, CAS 13479-54-4 — so what is left to choose is physical. Mesh, flow, dust and the decision to dilute into a carrier are the grade variables, and each one changes how the powder runs on a line. The copper figure stays near 30% unless a dilution is calculated and declared.
The grade decision has two layers: the chemical form fixes the copper figure at about 30%, and the physical form fixes how the powder flows, blends and fills.
Three meanings of “grade”
Three different purchases hide behind the word grade: a chemical form, a purity level and a particle size. In this product the chemistry is fixed. The catalog material is C4H8CuN2O4, CAS 13479-54-4, with an assay of 98.0–102.0% and copper at 29.0–31.0%, and the purity level is that catalog assay rather than a menu of potency options.
Copper gluconate is a separate ingredient, not a coarse or fine version of this one; its CAS number, formula and copper figure all differ. The comparison belongs on the bisglycinate versus gluconate page, not in a mesh table. What remains here is the physical grade and the project-specific dilution.
A carrier premix is a project material. Once the chelate is diluted, the copper figure, the carrier declaration, the assay and the label all move. That is not the catalog grade with a different mesh; it is a new specification with its own certificate.
The catalog form and its options
| Option | Copper | Plant behaviour | Typical fit | What must be re-specified |
|---|---|---|---|---|
| Catalog powder, 40 mesh | 29.0–31.0% | Free-flowing; some dust | Capsules, tablets, dry blends | Nothing; this is the baseline |
| Granulated powder | 29.0–31.0% | Coarser; less dust | High-speed blending and tableting | Mesh, flow and dissolution rate |
| Carrier premix | Lower, calculated | Depends on the carrier | Low-dose blending | Carrier, label, assay and copper figure |
| Copper gluconate | 13.5–14.5% | Freely soluble; blue-green | Aqueous systems and dry blends | Identity, CAS, label and fill |
Rows one and two share a certificate template; row three needs a new one; row four is another product altogether. Treating any two of them as interchangeable at the same weight is the most common purchasing error in this family.
Mesh, flow and the process
A 40 mesh sieve opens at roughly 420 µm, and the catalog asks for at least 95% of the powder to pass it. Finer particles disperse faster but make dust and can segregate in a blend. A granule flows more evenly into a tablet die and raises less dust, at the cost of slower dissolution and a possible gritty feel in a drink mix. The process should choose the grade, not the other way round.
Bulk density and flow rate are not in the catalog. If a feeder or a die needs a target, have the supplier measure it and write the result into the purchase specification; a mesh number does not predict how a particular powder will run. Granulation can be dry or wet, and a wet route adds water and a drying step to a material that already has a moisture limit. Ask which route is used before assuming two granulated samples behave alike.
The chelate takes up moisture from an open container. Caking, a duller blue and a rising loss on drying are the usual signs, and a granule can lose its flow before any chemical result moves. Pack and storage therefore belong to the grade in practice, even when the certificate does not mention them.
The copper figure and the fill
The label declares copper in milligrams; the powder mass is an internal calculation. At the theoretical 30.0%, 1 mg of copper needs 3.33 mg of the chelate, 2 mg needs 6.67 mg and 3 mg needs 10.0 mg. At 29.0% the same claims need 3.45, 6.90 and 10.3 mg; at 31.0% they need 3.23, 6.45 and 9.68 mg. The catalog range moves the weigh-up by roughly 7% from bottom to top.
| Label claim (Cu) | At 29.0% Cu | At 30.0% Cu | At 31.0% Cu |
|---|---|---|---|
| 1 mg | 3.45 mg | 3.33 mg | 3.23 mg |
| 2 mg | 6.90 mg | 6.67 mg | 6.45 mg |
| 3 mg | 10.3 mg | 10.0 mg | 9.68 mg |
A 2 mg claim puts about 7 mg of powder into a capsule that may weigh 300–500 mg. The copper source is a minor part of the fill, so the real problem is distributing it evenly, not finding room for it. A carrier premix or a granule can help; neither changes the copper figure, and a diluted grade changes both the figure and the label.
The table is a calculation, not a dosing instruction. The brand and its regulatory reviewer own the label claim. The specification's role is to ensure that the copper figure used in the calculation is the one on the certificate.
What to write into the specification
- “Identity: copper bisglycinate, CAS 13479-54-4, C4H8CuN2O4.”
- “Assay 98.0–102.0% by HPLC, with the basis named.”
- “Copper 29.0–31.0% by complexometric titration.”
- “FTIR and HPLC retention against a reference.”
- “Loss on drying ≤5.0%; blue and free-flowing.”
- “Particle size ≥95% through 40 mesh; a granulated option needs its own mesh and flow target.”
- “Metals, microbiology, pack, lot code and destination market.”
A granulated or diluted order is a new specification, not a footnote to the catalog one. State the grade and the form on the purchase order, and attach the mesh, flow or carrier details that apply.
When a different grade is the wrong choice
Granulation is the wrong lever when dissolution speed or suspendibility matters; granules can dissolve more slowly and can settle out of a drink. It is also unnecessary when the existing powder already feeds well and a new specification would add cost without a process gain.
A carrier premix is wrong if the label names only the chelate and the carrier is undeclared; the carrier is an ingredient in its own right. An equal-weight swap to copper gluconate is wrong too: at about 14% copper it delivers less than half the metal, and the label name changes with the source. The level-four comparison covers that switch.
The catalog specification sits on the product page. Release figures are explained on the COA page; the identity tests on the identity page; moisture and pack on the stability page; the other copper source on the copper gluconate page; sieve and assay methods in the methods library; the release sequence on the quality page.
In this document
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation