Squalene vs squalane: the unsaturated and the saturated form
Squalene is C₃₀H₅₀ with six double bonds; squalane is C₃₀H₆₂, the same carbon skeleton fully hydrogenated. The two are close in mass — 410.72 against 422.81 g/mol — but they behave differently in air, on a gas chromatograph and on a label. Squalane is not a purer squalene; it is a different substance.
Six double bonds and about twelve mass units separate squalene from squalane; that difference decides the stability, the analytical method and the name on the label.
One skeleton, six double bonds
Both materials are built on the same thirty-carbon triterpene skeleton. Squalene carries six carbon-carbon double bonds; squalane has none. Hydrogenation adds one molecule of hydrogen across each double bond, so six moles of hydrogen per mole of squalene convert it to squalane. The carbon chain does not change; the unsaturation does.
The mass change is small. Six hydrogen molecules add about 12.1 mass units to a squalene molecule of 410.72, a gain of about 2.9%. That is why the two are so close in density and why appearance cannot tell them apart. Both are colourless to pale yellow oils at room temperature, and both are insoluble in water and miscible with many oils.
“Fully saturated” is the whole distinction. It is not a purity grade, a filtration step or a dilution. A squalane certificate that also reports squalene is describing a residue or an incomplete reaction, not a blend of two grades.
The numbers side by side
| Property | Squalene | Squalane |
|---|---|---|
| CAS number | 111-02-4 | 111-01-3 |
| Formula | C₃₀H₅₀ | C₃₀H₆₂ |
| Molecular weight | 410.72 | 422.81 |
| Double bonds | Six | None |
| Iodine value | 350–380 g I₂/100 g | Near zero |
| Refractive index (20 °C) | 1.494–1.499 | About 1.450–1.452 |
| Density | About 0.858 g/mL | About 0.810 g/mL |
| Typical use | Food, supplement and personal-care oil | Personal-care oil |
The iodine value is the widest gap in the table: six double bonds give squalene a figure near 371, while a fully saturated oil gives almost nothing. The refractive index and the density follow the same direction. A laboratory can separate the two with a few grams of sample and two measurements, long before a chromatogram is run.
How the two are told apart
Both are hydrocarbons with no useful ultraviolet chromophore, so HPLC with UV detection is not the method of choice. GC with a flame-ionisation detector is the practical method. The method should name the column, the temperature programme and the reference standards for both materials, because the two peaks are close and a retention time without a standard proves little.
The iodine value is the decisive release figure. A squalene lot at 350–380 cannot be a squalane lot, and a squalane lot with an iodine value near zero cannot be squalene. The refractive index supports the result: 1.494–1.499 against about 1.450–1.452 is a gap far wider than the method's repeatability. Density is a useful third check but is not a release line.
If both materials are present, the GC profile and the iodine value together give the approximate split. A partially hydrogenated oil sits between the two, and its iodine value is the quickest way to see it. Appearance and colour are no help at all.
Stability is the practical difference
Squalene oxidises. Its six double bonds are sites for autoxidation, and the oil takes up oxygen during storage to form hydroperoxides, which then break down into aldehydes and other volatile products. The visible signs are a darker colour, a heavier odour and a rising peroxide value. The rate depends on light, heat, headspace oxygen and metal contact, not on the calendar alone.
Squalane is saturated and therefore much less reactive towards oxygen. That is why the saturated form became the usual personal-care oil: it does not develop the same oxidation products on the shelf. It is not indestructible — strong heat and light still change any oil — but its failure mode is not the rapid autoxidation that governs squalene.
The formulation consequence is direct. A squalene product needs an antioxidant, a low-oxygen pack and a dark container; a squalane product needs a clean pack and a sensible temperature, but not the same oxidation controls. The stability page sets out the protocol for the unsaturated material.
The label and the regulatory file
“Squalene” and “squalane” are different ingredient names. A product made with squalane does not declare squalene, and a product made with squalene does not declare squalane. The CAS number, the formula and the unsaturation all change, so a 1:1 substitution is not a labelling formality: it changes the molar amount as well as the name.
The use decides the framework. Squalene is sold as a food or supplement oil in some markets; squalane is used mainly in personal care, where the cosmetic rules apply. The buyer's regulatory team confirms the route for the destination, the finished product and the intended use. A cosmetic-grade squalane certificate does not establish a food use, and a food-grade squalene certificate does not make the material a cosmetic ingredient.
Source adds a second label question. Olive-derived squalene and squalane made from it can carry a source statement; the wording and the substantiation belong to the destination rules and the supplier's records. The certificate alone does not prove the botanical origin.
When to choose which
Choose squalene when the specification calls for the unsaturated material: a food or supplement oil, an oil blend, or a formula where the six double bonds are part of the identity. Choose squalane when the formula needs a saturated, oxidation-resistant oil and the label names squalane. Neither is a higher grade of the other.
If a project is switching from one to the other, the switch is a new material: new specification, new certificate, new stability work and a label check. The mass factor is small, but the analytical figures, the oxidation behaviour and the regulatory file are not. The squalene hub carries the unsaturated specification; the grades page places this comparison in the wider range; the identity page gives the tests; the stability page covers oxidation; the methods section explains the analytical approach.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation