What the COA for squalene actually contains
The certificate for a squalene lot reports appearance, identification by GC retention, assay by GC, refractive index, iodine value, moisture, the heavy-metal panel and microbiology. Each line needs three things: the method, the release limit and the measured result. The limits on this page are the catalog specification; the certificate is the record for one pack.
Three figures carry a squalene certificate: the GC assay, the refractive index and the iodine value, each with a method and a measured result beside its release limit.
The certificate as a test report
A certificate is auditable when every line can be read without a second document. The parameter says what was measured, the method says how, the limit says what the lot was released against, and the result says what the laboratory found. A row that reports only “conforms” gives a conclusion without the evidence.
The identity block is the one that separates squalene from squalane and from a diluted oil. The assay block says how much squalene is present. They need different lines on the page.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Colourless to pale yellow, clear oil |
| Identification | GC retention and refractive index | Conforms to the reference |
| Assay (GC) | GC assay | ≥90.0% |
| Refractive index (20 °C) | Refractometry | 1.494–1.499 |
| Iodine value | Wijs titration | 350–380 g I₂/100 g |
| Moisture | Karl Fischer | ≤0.1% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
What the assay, the refractive index and the iodine value each measure
The GC assay reports the squalene peak as a percentage of the oil, usually against an internal standard. Area normalisation without a standard assumes that every component has the same response, which is rarely true for a hydrocarbon mixture. Ask for the standard, the column and the integration basis. The catalog does not name the assay basis, so the certificate should state it. At ≤0.1% moisture the as-is and dry figures are close, but the row still needs the basis. The ≥90.0% gate also leaves up to 10% of the oil unaccounted for by the named peak, so the certificate should say what the balance contains rather than label all of it as impurity.
The refractive index is a fast physical check. It is measured at 20 °C, and the temperature belongs in the result because the value moves with it. A refractive index inside 1.494–1.499 is consistent with squalene but not specific to it; the number supports the identity, it does not prove it alone.
The iodine value is the unsaturation figure. It reports how many grams of iodine react with 100 g of oil, and each double bond reacts with one iodine equivalent. Squalene has six double bonds and a theoretical iodine value near 370.7; the catalog window is 350–380, which is about 94–102% of that figure. A saturated hydrocarbon contributes almost nothing, so the iodine value is also the first check against a squalane cut.
| Figure | What it measures | Why it matters |
|---|---|---|
| Assay (GC) | Squalene peak against a standard | How much of the oil is the named hydrocarbon |
| Refractive index | Optical property at 20 °C | A quick consistency check on identity |
| Iodine value | Iodine absorbed per 100 g | The number of double bonds in the oil |
| Moisture | Water by Karl Fischer | The assay basis and the hydrolysis risk |
Release limit versus batch result
The release limit is the boundary for the lot. The batch result is what the laboratory measured on that lot. Both belong on the page, in separate columns, with the method beside them. A result column filled with the specification range is not a result; it is a copy of the gate.
| Parameter | Release limit | Result column |
|---|---|---|
| Assay | ≥90.0% by GC | A measured percentage, with the standard and the integration basis |
| Refractive index | 1.494–1.499 at 20 °C | The measured value and the temperature |
| Iodine value | 350–380 g I₂/100 g | The measured value and the method |
| Moisture | ≤0.1% | The measured percentage |
| Heavy metals | Per element | A figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
“Passes specification” is a conclusion, and the reader should be able to reach it from the numbers. For heavy metals the evidence is a figure per element, not a single total; for microbiology it is a count plus an absence statement.
What moves between batches
The olive source, the crop year and the deodoriser-distillate batch move the colour, the assay and the unsaturation. The refining and deodorisation steps can shift it; storage before packing can move the peroxide value, which is not a catalog line but is the first oxidation signal. Two lots can both meet the same window and still differ in iodine value by twenty units.
Colour is the least quantitative line. Colourless to pale yellow covers a wide range, and a shift within it is not an identity failure. A batch that is noticeably darker can point to a longer hold or an oxidation product while the assay still passes; ask for the peroxide value and the batch record.
A trend across lots says more than one result near an edge: assay drifting low, iodine value falling, moisture climbing. The lot code on the certificate should match the bottle, the drum and the retained sample.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a source claim the certificate does not prove, or a disputed result. The useful panel is GC with a squalene standard, GC-MS for unknown peaks, refractive index, iodine value, moisture, heavy metals and microbiology.
Add peroxide value, acid value and saponification value when oxidation or a vegetable-oil dilution is suspected. The saponification value is close to zero for a hydrocarbon oil and rises when a triglyceride oil is present. Ask the laboratory to report its detection limit; a “not detected” line without a limit is evidence about the method, not about the sample.
Chain of custody matters: the sample tested should be the sample retained, and a contested result should go to a joint re-test on that sample rather than a repeat of the same assay.
What to compare between suppliers
Put six lines side by side: source and CAS number, assay result and basis, refractive index with temperature, iodine value with method, moisture and contaminants, and pack size with lot code. Two quotations that agree on assay but differ on iodine value are not describing the same oil.
The second layer is traceability. The certificate should say who manufactured the lot, the source, the distillation step and the pack. The catalog specification sits on the squalene product page. The tests that separate squalene from squalane are on the identity page; the market conditions are on the compliance page; the analytical methods are introduced in the methods section; the release workflow is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation