How to prove a squalane lot is squalane
A squalane lot can be called squalane only when three results agree: the GC assay, the refractive index and the iodine value. Appearance and colour cannot separate it from squalene. The iodine value is the decisive line: it measures the double bonds that hydrogenation was supposed to remove. The other two lines say which hydrocarbon is present and how much of it the oil contains.
Identity here is an agreement, not a single peak: GC names the hydrocarbon, the refractive index supports it, and an iodine value at or below 1.0 is what distinguishes the saturated form from squalene.
The identity layers
Each layer below is a separate question with its own evidence. A supplier who answers the first and stops has described a label, not a lot.
| Layer | Question | Evidence | What it establishes |
|---|---|---|---|
| Document | Is the material named? | Name, CAS number, formula, source | Paperwork, not the oil |
| Chromatography | Is the main peak squalane? | Retention against a squalane standard | The hydrocarbon |
| Refractometry | Does the optical value fit? | Refractive index at 20 °C | Consistency with the identity |
| Iodimetry | Is any unsaturation left? | Iodine value by Wijs | Whether hydrogenation completed |
| Mass balance | Is the oil diluted? | Assay, moisture and iodine value together | Whether the figures agree |
| Origin | Is the feedstock as claimed? | Source record and traceability | The supply chain, not the molecule |
The arithmetic behind the iodine value
Squalane is saturated, so its theoretical iodine value is zero and the catalog allows ≤1.0 g I₂/100 g. Squalene has six double bonds and titrates near 371. That gap turns the gate into a composition limit: 1.0 ÷ 371 ≈ 0.0027, so a passing lot can contain no more than about 0.3% unsaturated material measured as squalene.
The ratio runs the other way as well. A certificate with a 95.0% assay and an iodine value of 0.4 cannot have 5% squalene in the balance, because that would titrate near 18.5 and fail. The 5% must be saturated material — hydrogenation isomers, another hydrocarbon, or a residue that does not react with iodine. That is consistent with a complete reaction and inconsistent with a cut.
The physical figures move with the chemistry. Hydrogenating six double bonds raises the molar mass from 410.72 to 422.81, a gain of about 2.9%, and lowers the refractive index into the 1.450–1.455 window. A result near 1.494 would point back towards squalene however good the assay looked.
Why diffraction is the wrong test for this oil
Squalane is liquid at ordinary temperatures, so it has no lattice to diffract. A scan of the neat oil gives an amorphous halo, and a report that says “XRD conforms” without a reference phase says very little. The method answers questions about solids.
It becomes useful when the material is not the neat oil: a carrier-based solid, a blend with a crystalline excipient, or a suspicion that a solid diluent has been added. In those cases the pattern describes the matrix, while the squalane itself is still measured by GC, refractometry and iodimetry.
A disputed lot is better served by a GC run with both standards, a refractive index with the temperature recorded, and an iodine value than by a diffraction scan of a liquid.
What adulteration looks like
| Adulterant | Effect on the figures | What exposes it |
|---|---|---|
| Squalene or partial hydrogenation | Iodine value rises; a squalene peak appears | Iodine value and GC |
| Mineral oil | The chromatogram shows a series of peaks instead of one | GC-MS, refractive index, UV absorbance |
| Vegetable oil | Esters appear; the saponification value rises | FTIR, GC after transesterification |
| Ester or silicone oil | Carbonyl or silicon-oxygen bands appear | FTIR, GC-MS |
| Water | Moisture above the limit; the oil hazes | Karl Fischer |
The likely substitution is the one that looks the same in the bottle. A partly hydrogenated oil can pass a 95% assay and still carry enough unsaturation to fail the iodine value, which is why that line belongs on the release panel.
A mineral-oil cut is subtler. The physical figures can sit close to squalane, but the chromatogram shows a boiling-range series instead of a single peak, and the ultraviolet absorbance can rise where a pure hydrocarbon oil is transparent. Source claims are separate again: the certificate proves the molecule, while the origin record proves the feedstock.
How to write the identity into the specification
- “Squalane, olive-derived, CAS 111-01-3, C30H62.”
- “Assay ≥95.0% by GC, with the calibration mode and the standard stated.”
- “GC retention and refractive index 1.450–1.455 at 20 °C for identification.”
- “Iodine value ≤1.0 g I₂/100 g by Wijs, reported as a measured figure.”
- “Moisture ≤0.1% by Karl Fischer; metals and microbiology as listed.”
- “Residual squalene reported, with a limit agreed for the grade.”
- “Source and hydrogenation step declared; lot code traceable to the retained sample.”
Five questions for the supplier
- Which standard calibrated the GC assay, and how was the peak integrated?
- At what temperature was the refractive index measured?
- What iodine value did the lot return, and by which titration method?
- How much residual squalene is present, and how does that figure compare with the iodine value?
- If we dispute a result, will you re-test the retained sample jointly?
The answers, not the headings, make the identity file. A single assay percentage is the weakest version of that file. The catalog specification is on the product hub; each figure is placed on the certificate by the COA page; source and use options are compared on the grades page; the saturated and unsaturated forms are set out in the level-four comparison; the unsaturated material has its own squalene page; the analytical approach is introduced in the methods section; the release file is described on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation