What the COA for squalane actually contains
A squalane certificate has to settle three questions in one document: that the oil is the saturated hydrocarbon, how much of it the lot contains, and whether the hydrogenation ran to completion. The panel that does this is appearance, GC identification and assay, refractive index, iodine value, moisture, heavy metals and microbiology. The limits below are the catalog specification; the certificate itself records one lot against them.
The GC assay states how much squalane is present, the refractive index supports the identity, and an iodine value at or below 1.0 is the line that shows the double bonds are gone.
Reading the certificate line by line
A useful certificate is one a reviewer can audit without a telephone call. Each row should name the test, the method, the acceptance limit and the measured value, and the method should be specific enough to repeat: “GC” alone does not say which column, which detector or which standard was used.
The identity rows and the quantity rows are not interchangeable. Retention on the GC and the refractive index place the material in the right family; the iodine value says whether the double bonds were removed; the assay says what fraction of the oil the main peak represents. Leave the iodine value out and the certificate can still describe a partly hydrogenated oil as squalane.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Colourless to pale yellow, clear oil |
| Identification | GC retention and refractive index | Conforms to the reference |
| Assay (GC) | GC with flame-ionisation detection | ≥95.0% |
| Refractive index (20 °C) | Refractometry | 1.450–1.455 |
| Iodine value | Wijs titration | ≤1.0 g I₂/100 g |
| Moisture | Karl Fischer | ≤0.1% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
Which numbers need a stated basis
Two rows on this panel need a stated basis, and neither is the moisture row. The assay needs to say whether it was calculated by area normalisation or against an internal standard, and whether the percentage refers to the oil as received. The iodine value needs the titration method named, because Wijs and Hanus do not return identical numbers on the same oil.
Area normalisation is the common shortcut. It divides the squalane peak area by the total area of all peaks, which assumes that every component responds like squalane. In a hydrocarbon oil that assumption is approximate: isomers and residual squalene can have different response factors. An internal standard, added before injection, removes the assumption and makes the figure comparable between laboratories.
Another basis question is what the balance contains. The ≥95.0% floor allows up to 5% outside the named peak, and calling all of it impurity is not an analysis. The certificate should identify residual squalene, hydrogenation isomers or feedstock hydrocarbons. The iodine value is the independent check: squalene titrates near 371 g I₂/100 g and squalane near zero, so a value of 1.0 caps unsaturated material at about 0.3%.
Release limit, result and the difference
A limit is a boundary; a result is a measurement. When the result column repeats the limit, the reader has no evidence that a measurement happened. The table below sets out what a measured column looks like for each test.
| Parameter | Release limit | Result column |
|---|---|---|
| Assay | ≥95.0% by GC | Value, calibration mode and integration basis |
| Refractive index | 1.450–1.455 at 20 °C | Value and cell temperature |
| Iodine value | ≤1.0 g I₂/100 g | Value and titration method |
| Moisture | ≤0.1% | Value by Karl Fischer |
| Heavy metals | Per element | mg/kg for each element, with the method |
For the metal panel, a single summed figure is not enough, because the element that matters is hidden in the total. For microbiology, the certificate needs a count and an absence statement, not the word “pass”.
Where lot-to-lot variation comes from
The feedstock is the first source. The catalog route starts from olive deodoriser distillate, a refining stream whose composition follows the crop, the refinery and the season. Hydrogenation then introduces its own variables: catalyst activity, hydrogen pressure, temperature and residence time. A complete reaction drives the iodine value towards zero; a run that ends early leaves a measurable squalene fraction.
Finishing steps account for much of the rest. Catalyst removal and deodorisation affect colour and odour, and a batch that is slightly darker than the previous one may simply have seen a longer heat hold. The colour window is wide, so the batch record and an instrument colour reading are better evidence than appearance alone.
Handling explains the moisture and microbiological results. A drum opened in a humid room, a filter that stayed wet, a bottle left uncapped: each shows up as water or as a count. Matching the certificate's lot code to the bottle, the drum and the retained sample is the simplest check that the document describes the material in hand.
When an outside laboratory earns its fee
Independent testing makes sense at four moments: a new source, a first shipment to a regulated market, a marketing claim the supplier's certificate does not cover, and any disputed result. The panel should target the question rather than duplicate the release certificate: GC with standards for squalane and squalene, refractive index with the temperature recorded, iodine value, Karl Fischer moisture, ICP-MS metals and microbiology.
Two additions cover specific worries. FTIR will show a carbonyl or a silicon-oxygen band that a pure hydrocarbon should not have, and GC-MS will identify an unexpected peak. A source claim needs different evidence: the molecular tests prove the hydrocarbon, but only the origin record and the traceability chain support the word “olive”.
Chain of custody decides whether the result is usable. The portion tested should come from the same pack as the retained sample, and the report should carry the lot code. In a dispute, the referee needs the retained sample, the certificate and the specification, and a test designed to distinguish saturation from dilution is more informative than a second run of the same assay.
Six lines for a supplier comparison
Line up the name and CAS number, the assay with its calibration mode, the refractive index with temperature, the iodine value with method, moisture and metals, and the pack with its lot code. An offer that matches on assay but not on iodine value is a different material.
Traceability is the second layer: who hydrogenated the lot, where the feedstock came from, how the catalyst was removed, and which filtration and deodorisation steps were applied. Start from the squalane product page for the catalog specification, then read the identity page for the tests that separate the saturated form from the unsaturated one and the compliance page for the market documents. The unsaturated material has its own squalene page; the analytical methods are introduced in the methods section; the release workflow is described on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation