01 COA & batch testing

What the COA for phytosterol esters actually contains

Technical document 01 · Reviewed 2026-11-20 · Phytosterol Esters

On this page
  1. The certificate as a test report
  2. Ester content, total sterols and the work-up
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A phytosterol ester certificate reports two different quantities: the ester content, which says how much of the sterol is esterified, and the total sterols, which says how much sterol the lot carries after hydrolysis. Acid value and peroxide value describe the fatty acid part of the molecule, and the heavy-metal and microbiology panels cover the rest of the release decision. The limits below are the catalog specification; the batch certificate reports a result for a particular lot.

In one line

Ester content and total sterols are separate release gates: the first shows how much sterol is esterified, the second shows how much sterol the lot carries, and a certificate needs both before the lot is released.

The certificate as a test report

A certificate is auditable when each line names the parameter, the method and the release limit, and leaves a separate column for the measured result. A row that says only “conforms” offers a verdict, not the evidence for it.

The identity row and the ester content row answer different questions. The identity row asks whether the sterol profile matches the agreed reference; the ester content row asks how much of that sterol is in the ester form. A lot can pass the profile and still be under-esterified.

Identity, ester content and fatty-acid quality · phytosterol esters
TestTechniqueLimit
AppearanceVisualWhite to off-white paste or powder
IdentificationGC sterol and ester assay against standardsSterol profile conforms
Ester contentGC, ester fraction≥90.0%
Total sterolsGC after saponification≥55.0%
Acid valueTitrimetric≤1.0 mg KOH/g
Peroxide valueIodometric≤5.0 meq O₂/kg

The ester content and the total sterol result are two views of the same molecule; neither replaces the other.

Ester content, total sterols and the work-up

The two numbers come from different work-ups. Total sterols are measured after alkaline hydrolysis: the ester bond is cleaved, the unsaponifiable matter is extracted, and the sterols are separated by GC and summed. The result is the sterol cargo, not the intact ester. Ester content is read from the ester fraction, either directly by GC or by combining the sterol and fatty-acid results; the certificate should name the route, because ester figures from different methods are not automatically comparable.

At the catalog floor, 90.0% ester content and 55.0% total sterols imply that the ester itself is about 61% sterol by mass (55 ÷ 90). The rest is fatty acid. A lot with 92% ester and 57% total sterols is coherent; a lot with 92% ester and 50% total sterols needs an explanation in the fatty-acid or free-sterol balance.

The fatty acid is the other half of the molecule. It can come from a food-grade vegetable oil, and the source is agreed in the specification because it sets the allergen statement, the melting behaviour and the oxidation profile. The catalog does not fix one fatty acid, so the source belongs in the purchase specification rather than in a default assumption. Acid value and peroxide value, tested on release and again in storage, are the quality lines for that fatty acid.

Release limit versus batch result

The limit is the acceptance boundary; the result is what the laboratory measured. Keep them in separate columns and name the method beside each. If the result column simply repeats the limit, no measurement has been reported.

What the result column should show
TestLimitResult
Ester content≥90.0%A measured percentage, with the ester method
Total sterols≥55.0%A measured percentage, with the hydrolysis and GC method and the basis
Acid value≤1.0 mg KOH/gA measured value in mg KOH/g
Peroxide value≤5.0 meq O₂/kgA measured value in meq O₂/kg
Heavy metalsPer elementEach metal reported separately, in mg/kg
MicrobiologyCounts and absencePlate count plus the absence result for the lot

“Passes specification” is a verdict, and the numbers on the page should support it. Microbiology needs a count and an absence result; the metal panel needs one line per element rather than a combined total.

The catalog has no loss on drying line and no separate free-sterol limit for this product. The total sterol and ester results should still state whether they are as-is or dried, with the moisture result beside them, and free sterol is the additional test when the form is critical.

What moves between batches

Between lots, the fatty acid source and the degree of esterification move the ester content and the total sterols together. A source change can keep both inside the catalog limits and still change the melting behaviour, the colour and the oxidation rate. The source is part of the specification, not a purchasing detail.

Hydrolysis moves the pair in the other direction: ester content falls, free sterol rises, and acid value rises as fatty acids are released. Total sterols can stay close to the same value because the sterol is still in the sample; the form has changed, not the sterol mass. Oxidation moves peroxide value first and colour later, and colour is the weaker signal.

The physical form moves with temperature. A paste that has been through a warm-cold cycle can look grainy or show a surface film; warming the closed pack gently and mixing before sampling is the practical response. The certificate's lot code should be traceable to the pouch, the drum label and the sample kept on file. Watch the trend across lots, not only the latest result.

When to order an outside test

An outside laboratory earns its place with a new source, a first shipment, a disputed form, a warm-stored lot or a new market. The useful panel is the GC ester and total sterol assay with the chromatogram, free sterol, the fatty acid profile, acid value, peroxide value, ICP-MS for the heavy metals and a plate count with absence tests.

Add p-anisidine value when the lot has seen heat or the application is a fat blend, because peroxide value alone misses secondary oxidation. Add sterol oxidation products, such as 7-keto and 7-hydroxy derivatives, when the storage history is unknown, and residual solvents if the extraction route is unclear. Ask for the detection limit behind any “not detected” line.

What to compare between suppliers

Put seven lines side by side: form, ester content, total sterols and the basis, free sterol, acid value and peroxide value, fatty acid source and carrier, pack and lot code. Two offers that agree on ester content but differ on form or carrier are not the same material.

The second layer is traceability: who manufactured the lot, which fatty acid source was used, and how the material was finished and packed. Specification: the ester hub. Form: the grade page. Identity tests: the identity page. Free-sterol reference: the phytosterol hub. GC background: the methods index. Release: the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation