01 COA & batch testing

What the COA for DHA powder actually contains

Technical document 01 · Reviewed 2026-11-19 · DHA Powder

On this page
  1. The certificate as a test report
  2. What the 10% figure measures
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A DHA powder certificate reports an oil diluted into a carrier, not a neat fatty acid. It should show DHA by GC, the fatty-acid profile, moisture, peroxide and p-anisidine values, the carrier, the mesh and the contaminants. The catalog limits are DHA ≥10.0%, moisture ≤5.0%, peroxide value ≤5.0 meq/kg and p-anisidine value ≤20.0; the batch COA confirms one lot, not the next.

In one line

A DHA certificate has to report the assay, the oxidation state and the carrier, because a 10% figure can pass while the oil behind it has aged.

The certificate as a test report

A certificate is auditable when every line names the analyte, the method and the release limit, and when the product name, CAS 6217-54-5 and lot code tie the sheet to the material. A sheet that prints the specification range in the result column has reprinted the gate, not reported a measurement.

For a microencapsulated powder, two lines are easy to omit: the carrier and the oxidation pair. The carrier is part of the ingoing weight and may be an allergen source; peroxide and p-anisidine values describe the oil inside the matrix, which the DHA assay does not. Appearance matters too, because a colour shift can be the first visible sign that the oil has moved.

Identity, assay and lipid limits · microencapsulated DHA powder 10%
ParameterMethodRelease limit
DHAGC after methylation≥10.0%
EPASame fatty-acid runReported
MoistureGravimetric≤5.0%
Peroxide valueTitrimetric, e.g. ISO 3960 or AOCS Cd 8b-90≤5.0 meq/kg
p-Anisidine valueSpectrophotometric, e.g. ISO 6885 or AOCS Cd 18-90≤20.0
CarrierComposition declarationModified starch and antioxidant, declared
Particle sizeSieve analysis≥95% through 40 mesh
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The method column is not decoration. GC measures fatty acid methyl esters, so the certificate should say the oil was methylated, which detector was used and how peaks were identified. Peroxide value counts hydroperoxides; p-anisidine value reacts with the aldehydes formed when they break down. One can fall while the other rises. The catalog limit fixes DHA; EPA is reported so the profile can be checked.

What the 10% figure measures

The catalog figure is DHA in the powder as sold, by GC. It is a concentration, not a purity: the rest is carrier, moisture, other fatty acids and the non-DHA part of the oil. A 10% powder can be a 25% oil load at 40% DHA in the oil, or a 40% load at 25% DHA. Both meet the assay; they are not the same material.

That is why oil load or fat content belongs beside the assay. Without it the buyer cannot calculate how much carrier arrives per gram of DHA or check a label that declares the oil. The starch and antioxidant are not identified by the 10% figure.

The basis also needs a definition. DHA can be expressed as free fatty acid, triglyceride or methyl ester, and the numbers are not interchangeable. The certificate should state the form and conversion, and the specification should use the same basis. Area percent from a chromatogram is a composition ratio, not a weight percentage of the powder.

Release limit versus batch result

The release limit is the boundary; the batch result is what the laboratory measured. Keep them in separate columns with the method beside each. A lot can pass all three limits with the peroxide value near the ceiling and still be a poor choice for a formula stored warm; the DHA figure would not show it.

Moisture works the same way. At ≤5.0% the powder is inside the specification, but moisture near the ceiling shortens the distance to caking and hydrolysis. Encapsulation protects the oil from the outside; it does not remove water already inside the matrix.

“Reported” is a requirement, not a blank. If EPA is reported, the figure and method should be there. If a heavy-metal panel says only “passes”, ask for the values and the limit of quantification. A conclusion is not a result.

What moves between batches

DHA is a natural oil fraction, so the assay moves with the oil batch and the source. The oil load set at the encapsulator moves with the emulsion and the dryer, and the DHA percentage follows both. A supplier change can move DHA, EPA and the minor fatty acids together.

Peroxide and p-anisidine values move with heat, oxygen and time. Emulsification, spray drying and milling add exposure, and a clean lot can arrive higher if the pack is not a barrier. Mesh moves with the mill and sieve; colour with the oil and drying temperature.

Compare a new lot with the previous one on the same lines, not only against the limits. Two lots can both pass and still change a capsule fill or a stick dose. That comparison is a specification review, not a rejection.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, a disputed result or an unsupported claim. The useful panel is targeted: DHA and EPA by GC with a certified standard and the chromatogram; peroxide and p-anisidine values by a named method; moisture; the fatty-acid profile; source markers where substitution is suspected; and ICP-MS for heavy metals.

Ask for the limit of quantification and the chromatogram. “Not detected” without a limit describes the method, not the sample. For a source claim, read the fatty-acid profile with the declared oil source; a DHA number alone does not separate fish oil from algal oil.

What to compare between suppliers

Two quotations that agree on 10% DHA can still describe different powders. Make the supplier fill six lines.

Six lines that decide whether two DHA powder quotations describe the same material
LineWhat to ask forWhat it separates
SourceOil source, producer and originTwo materials with the same assay and a different label
Assay basisDHA result, GC method, standard and expression basisA measured lot from a copied range
ProfileEPA and the other fatty acids in the same runA DHA concentrate from a blended oil
OxidationPeroxide and p-anisidine values on the lotA fresh oil from an aged one
CarrierStarch type, antioxidant and oil loadA declared matrix from an assumed one
TraceabilityLot code on certificate, pack and retained sampleA lot record from a generic sheet

The catalog specification sits on the DHA powder product page. The powder-versus-oil decision is set out on the grade page; the tests that separate a DHA lot from a blended oil are on the identity page; the behaviour of the oil over time is on the stability page. The document terms are defined in the COA glossary entry, and the quality page explains how lots and retained samples are held.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation