01 COA & batch testing

What the COA for CLA powder actually contains

Technical document 01 · Reviewed 2026-11-19 · CLA Powder

On this page
  1. The certificate as a test report
  2. What the 10% figure measures
  3. Release limit versus batch result
  4. What moves between lots
  5. When to send a lot out
  6. Six lines to compare between suppliers

A CLA powder certificate is a report on the powder as sold, not on the oil inside it. It should give total conjugated linoleic acid by GC, the distribution of the main isomers, the oil load, moisture, peroxide value, p-anisidine value, particle size, heavy metals and microbiology, each with a method and a release limit. The figures here are catalog limits; the batch COA is the record for one lot.

In one line

A CLA certificate has to report the total CLA by GC, the isomer distribution, the oil load and the oxidation values, not a single 10% figure.

The certificate as a test report

Each line needs the parameter, the method, the release limit and the result. A parameter without a method cannot be repeated; a limit without a result is a specification; a result without a basis can be read two ways. The header should name the product, grade, lot, dates, specification and releasing site.

This product is a powder, so every result also depends on how the oil was recovered from the starch. The certificate should say whether the CLA and the oxidation values were measured on the powder or on the extracted oil, and which extraction was used.

Identity, assay and quality limits · microencapsulated CLA powder 10%
ParameterMethodRelease limit
CLA (total)GC of fatty acid methyl esters≥10.0%
Isomer distributionGC, c9,t11 and t10,c12 integrated separatelyReported for the lot
Oil loadCalculated from the extracted fatReported for the lot
MoistureGravimetric loss on drying≤5.0%
Peroxide valueTitrimetric, on a stated basis≤5.0 meq/kg
p-Anisidine valueSpectrophotometric≤20.0
Particle sizeSieve analysis≥95% through 40 mesh
Heavy metalsElemental analysis, ICP-MS or ICP-OESPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The c9,t11 and t10,c12 isomers sit close together, and a short column or a loose method can merge them, or merge one with linoleic acid. The certificate should name the column, the detector, the isomer standards and the integration.

What the 10% figure measures

The 10.0% is the mass of conjugated linoleic acid in the powder, expressed as the sum of the conjugated isomers, on the powder as sold unless the certificate states another basis. It is not the oil load. The oil is a mixture of CLA isomers and other fatty acids, so the oil load is higher than the CLA figure; a 10% CLA powder can carry a substantially larger percentage of oil. The balance is the non-CLA part of the oil, the modified starch carrier, the antioxidant, moisture and minor solids.

That mass balance is the first arithmetic check. CLA content equals oil load multiplied by the CLA concentration of the oil. A 10% CLA result with an oil load barely above 10% would describe an oil that is almost pure CLA, which a commercial oil is not. Ask for both figures and do the multiplication.

The extraction is part of the result: the oil is locked in the starch, and the laboratory has to break the matrix without losing or oxidising it. The certificate should describe the preparation. The total is also not the isomer ratio: two powders can both report 10.0% while carrying different proportions of c9,t11 and t10,c12.

Release limit versus batch result

The release limit is the gate the lot had to pass; the batch result is what the laboratory measured. They belong in separate columns, next to the method. A result column filled with the limit range is a copy of the gate, and a line that says “conforms” is a conclusion, not a measurement.

Peroxide value is where the basis matters most. The catalog limit is written as meq/kg, and for a 10% powder that number can be read per kilogram of powder or per kilogram of extracted oil. The two differ by roughly the oil load, so a value that looks low on the powder can be high on the oil. Ask which basis is used, and keep the same basis when comparing suppliers. AOCS Cd 8b-90 and ISO 3960 are the usual titration references; the certificate has to state which one was used.

The p-anisidine value measures secondary oxidation products, mainly aldehydes, and it is dimensionless. It rises later than the peroxide value, so a lot with a low peroxide value and a high p-anisidine value has already been through an oxidation episode. Read the two together, against the storage history. The method is commonly AOCS Cd 18-90 or an equivalent.

What moves between lots

The CLA figure moves with the oil, the oil load and the encapsulation efficiency. A different oil batch brings a different isomer ratio and a different minor fatty acid profile; a change in the starch or the emulsion brings a different oil load; a change in drying or milling moves the moisture and the particle size. The certificate is a record of all three, not only the assay.

The oxidation values move with the oil's history and with the process. Heat in the drier, oxygen in the emulsion, trace metals from the equipment and light during handling all push the peroxide value up. Surface oil — the fraction that sits outside the starch wall — is the most exposed part, and it is not a standard line on the catalog certificate. Ask for surface oil as an additional test if oxidation is critical.

When to send a lot out

Order an independent test for a new oil source, a first shipment into a regulated market, a disputed result, or a label that names an isomer ratio. The useful panel is targeted: total CLA and the isomer distribution by GC, with a chromatogram and the standards named; peroxide and p-anisidine values by a named method on a stated basis; moisture; heavy metals by ICP-MS; microbiology; and a fatty acid and sterol profile if dilution with another oil is suspected. Ask for the limit of quantification and the raw peak areas.

Six lines to compare between suppliers

Six lines that decide whether two CLA quotations describe the same powder
LineWhat to ask forWhat it separates
Grade and identity10% or 20%, source oil, CAS and product nameTwo powders sold under one name
CLA resultLot result, GC method, column and standardA measured lot from a copied specification
Isomer ratioc9,t11 and t10,c12, with the basisA declared ratio from an unstated one
Oil load and carrierOil load, starch source, antioxidantDifferent fill weight and label
OxidationPV and p-AV, method and basisA fresh oil from an aged one
Lot traceSame lot code on COA, pack and retained sampleA certificate that belongs to another lot

The catalog specification sits on the CLA powder product page. The concentration options are compared on the grade page, and the tests that separate CLA from another oil are on the identity page. The certificate terms are defined in the COA glossary entry, and the elemental panel is explained in the ICP-MS method note.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation