01 COA & batch testing

What the COA for phytase actually contains

Technical document 01 · Reviewed 2026-11-20 · Phytase

On this page
  1. Reading the certificate line by line
  2. What one FTU is, and why the blank matters
  3. The limit and the measured result
  4. Batch-to-batch variation
  5. When an outside laboratory is worth it
  6. Comparing two offers

A phytase certificate reports activity in FTU per gram, and that figure is a rate: sodium phytate is the substrate, pH 5.5 and 37 °C are the conditions, and inorganic phosphate is the readout. The same sheet carries appearance, loss on drying, the heavy-metal panel, microbiology and particle size. The catalog specification here is ≥10,000 FTU/g, and a batch COA is tied to the pack it released.

In one line

A phytase result is a rate in FTU/g, and it means something only with the substrate, the pH, the temperature and the blank that produced it.

Reading the certificate line by line

A certificate can be audited when every line answers three questions: what was measured, by which method, and against which release limit. A row that says “conforms” gives the conclusion but not the measurement. For an enzyme, the activity line is the product itself.

Release tests and methods · phytase powder
ParameterMethodRelease limit
AppearanceVisualOff-white to light tan powder
ActivitySodium-phytate assay, inorganic phosphate readout, pH 5.5, 37 °C≥10,000 FTU/g
IdentificationActivity assay conformConforms to the reference
Loss on dryingGravimetric≤8.0%
Heavy metalsICP-MS, as stated on the certificatePb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

Identification by activity assay is a legitimate entry for an enzyme preparation: if the powder catalyses the defined reaction under the defined conditions, it is the material the method recognises. That entry only works when the method travels with it. Without the substrate, the pH and the standard, “assay conform” describes a procedure the reader cannot see.

What one FTU is, and why the blank matters

One FTU is the amount of enzyme that releases one micromole of inorganic phosphate per minute from sodium phytate at pH 5.5 and 37 °C, the definition used in EN ISO 30024. That is why an activity figure cannot be read without its method: a laboratory that runs the incubation at a different pH, temperature or substrate concentration is measuring a different rate and may still print the same three letters.

Two details decide whether the number is real. The first is the blank. The powder can carry phosphate from the fermentation medium or from the carrier, and the colorimetric readout counts total inorganic phosphate rather than only the phosphate the enzyme released. A sample blank stopped before incubation is subtracted from the reading. Leave it out and a lot with added phosphate reads high while carrying less enzyme.

The second is the basis. Activity is reported per gram of powder as received, not per gram of dry matter, so the loss on drying belongs beside it. Water dilutes the powder: a lot at 8.0% moisture holds less enzyme per gram than a lot at 4.0% at the same printed activity. Neither figure alone describes the material.

pH 5.5 is also a condition of the assay, not a description of the gut. Activity measured there does not show how much enzyme survives an acidic stomach. That is an application measurement, and it belongs in the trial file rather than on the release certificate.

The limit and the measured result

Activity is a floor, not a target. A lot at 10,300 FTU/g and a lot at 13,800 FTU/g both pass ≥10,000 FTU/g, and the second carries more headroom into a process step that will consume part of it. The result column is where that difference becomes visible; a column that repeats the limit tells the reader nothing.

The result column, line by line
ParameterRelease limitResult column
Activity≥10,000 FTU/gA measured figure in FTU/g, with the method reference and the release date
Loss on drying≤8.0%The measured percentage
Heavy metalsPer elementA figure per element in mg/kg
MicrobiologyCounts and absenceThe lot's count and absence statement
Particle size≥95% through 80 meshThe measured percentage through the sieve

Two dates matter as much as the numbers: the release date and the end of the declared shelf life. Activity falls in storage, so a specification that guarantees 10,000 FTU/g at release does not describe the same drum six months later. Ask which date the limit applies to, and get the answer on the specification rather than in an email.

Batch-to-batch variation

Fermentation titre, recovery yield, carrier loading and drying move the activity per gram. Granulation moves the particle-size result and the dust; it need not move the activity when the preparation is standardised after granulation. The assay itself has a repeatability, so a result only a few percent above a one-sided limit is worth a retest.

Colour and odour are the least quantitative lines and often the first to raise a question. A darker or duller powder can come from a different drying step while the activity still passes. Use appearance to open the question, then settle it on the measured lines.

A trend across lots says more than any single result near an edge: activity drifting down toward the limit, moisture climbing, or a carrier change that shows up as a different sieve result. The lot code on the certificate, the pouch, the drum and the retained sample should all agree.

When an outside laboratory is worth it

An independent assay is worth ordering when the source is new, when a lot is the first into a regulated market, when the activity figure is disputed, or when a lot may have seen heat in transit. The panel worth paying for is not a copy of the certificate: activity by the named method with its blank and standard curve, loss on drying, protein for specific activity, heavy metals, microbiology, and a pH-activity profile when the source is in question.

The laboratory should state its detection limit and its repeatability next to each result. A “not detected” entry that carries no limit describes the method, not the sample.

Custody matters as much as the method: the sample assayed should be the sample kept, and the report should name the lot. When a result is contested, the referee should receive three things: the retained sample, the supplier's certificate and the specification. The request is the measurement that separates the two claims, not another run of the same assay.

Comparing two offers

Six lines make the comparison: unit definition and method reference; activity result with loss on drying; appearance and particle size; heavy metals and microbiology; carrier and granulation; pack, lot code and release date. Two quotations that agree on 10,000 FTU/g but differ on pH, substrate or blank are not the same number.

The second layer is traceability: who manufactured the lot, which strain and fermentation route were used, which carrier was added, and how the lot was dried and milled. Start with the phytase product page for the catalog specification; the grades page compares activity tiers and physical forms; the analytical methods library describes the assay behind the unit; the quality page sets out the release workflow.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.