What the COA for nattokinase actually contains
A nattokinase certificate reports appearance, activity in FU/g, pH, loss on drying, particle size, heavy metals and microbiology. The activity row is the only line that describes the enzyme, and it is unreadable without the unit definition, the fibrin substrate and the conditions beside it. The values below are the catalog specification; the batch COA confirms a particular drum of nattokinase powder against them.
An FU figure is a rate measured on a fibrin substrate under one set of conditions, so the certificate has to name the method, the substrate and the basis beside the number.
The certificate as a test report
A certificate can be audited only when every row carries what was measured, the method and the release limit. For an enzyme the activity row needs a fourth element: the assay conditions. Without them, a second laboratory cannot reproduce the result.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Off-white to light tan, free-flowing powder |
| Nattokinase activity | Fibrin substrate assay, FU/g | ≥20,000 FU/g |
| pH (1% solution) | Potentiometry | 6.0–8.0 |
| Loss on drying | Gravimetric | ≤8.0% |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤10,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
Read by rows: a lot can pass activity and fail moisture, pH or the heavy-metal panel.
What the FU/g figure measures
FU stands for fibrin degradation unit. One FU is defined by the assay that produces it: a rate of substrate change under stated conditions, not a mass or a purity percentage. The common trade definition is an absorbance increase at 275 nm of 0.01 per minute. Other method sheets use 1 µg of tyrosine released per minute, or a defined lysis area on a fibrin plate. Those are different measurements, and their numbers are not interchangeable.
The substrate is fibrin, and that choice defines what the assay sees. A preparation can carry fibrin-directed activity and still contain other proteins from the fermentation, so FU/g describes action on that substrate rather than the content of one molecule. The EU novel-food entry names the unit but leaves the numerical definition to the method of Takaoka et al. (2010). The method reference belongs in the specification, not a footnote. The note on FU and IU sets out the unit question in full.
| Element | What the certificate has to say | Why it moves the figure |
|---|---|---|
| Unit | FU per gram of powder as sold | Per gram of preparation, not per gram of protein |
| Substrate | Fibrin, in the form the method specifies | A different substrate counts a different action |
| Temperature | Usually 37 °C, as the method sheet states | A rate at one temperature does not describe another |
| pH | Near 7.8 in the common method | The same powder reads differently away from the working pH |
| Detection | Absorbance at 275 nm, tyrosine colour, or lysis area | Three observations, three scales |
| Basis | As-is, with the loss-on-drying result beside it | Water lowers the activity per gram at unchanged dry solids |
Release limit versus batch result
The limit is the gate and the result is what the laboratory measured. They belong in separate columns, with the method and the lot number attached. A result column that repeats the specification is not a result; “conforms” is a conclusion the reader should reach from the numbers.
The activity limit is one-sided. A lot just above the floor and one far above it both pass ≥20,000 FU/g; the second gives more headroom for a process step that removes activity. That headroom is a technical choice. Fix the reporting resolution and the acceptance rule, because a result rounded to the nearest 1,000 FU/g against a 20,000 floor leaves a wide band.
The release date and storage condition belong on the certificate, because the figure describes the lot at release, not at the end of shelf life. The loss-on-drying result belongs beside the activity, because the result is per gram as sold. A drum received six months after release is bought at the activity it still carries, so say whether the guarantee is at release or at the end of shelf life.
What moves between batches
Fermentation sets the starting point. The strain, the soy substrate, the medium, the induction and the harvest time shift the balance of proteins in the broth, and recovery and purification decide how much of that balance reaches the concentrate. Standardisation then fixes the activity per gram, by blending with a carrier or by selecting a cut. The spread between lots is a process decision as much as a biological one.
Drying and milling move the number again. A wetter powder reads lower per gram at constant dry solids, and a milling step that generates heat can remove activity before the sieve is reached. Colour is the least quantitative signal and often the most revealing: a darker tan can follow a hotter dry or a longer hold while the assay still passes.
Watch the method as closely as the number. If the substrate, buffer, incubation time or detection step changes between lots, two certificates that both say FU/g are not comparable. The identity page sets out the source and protein checks that sit beside the assay.
When an outside laboratory is worth ordering
An independent test is worth ordering for a new source, a first shipment into a regulated market, a label claim that rests on the activity figure, or a disputed result. The panel is narrow: activity by the buyer's FU method on a retained sample, protein content, loss on drying, heavy metals by ICP-MS, microbiology and a protein pattern by gel electrophoresis.
The referee has to run the same substrate and conditions as the specification, or the comparison measures methods rather than powder. Ask for the detection limit on each metal; “not detected” without a limit describes the method, not the sample. The sample tested should be the sample retained, with the lot code on the bag, certificate and submission form. Send the supplier's certificate and the specification to the referee before it starts, so the disagreement is about the measurement rather than the paperwork.
What to compare between suppliers
| Line | What to ask for |
|---|---|
| Source | Bacillus subtilis natto, the strain and the soy origin |
| Unit and method | FU/g, with the substrate, temperature, pH and detection step |
| Result | The measured value, the release date and the basis |
| Protein | Protein content or specific activity, with the method |
| Physical | Loss on drying, pH of a 1% solution and the mesh result |
| Contaminants | Heavy-metal and microbiological results against limits |
| Carrier and lot | Any diluent declared, and the lot code that matches the pack |
Two quotations that agree on FU/g but disagree on the method, source or carrier are not describing the same preparation. The catalog figures sit on the product page, and the vocabulary is in the COA glossary entry.