FU vs IU: what a nattokinase unit actually means
FU (fibrin degradation unit) and IU are both activity units for nattokinase, and they are not two names for the same measurement. FU is defined on a fibrin substrate; IU is defined on a synthetic chromogenic peptide. Each unit is a rate under a named method, so a figure in one unit cannot be converted into the other by arithmetic.
FU and IU are two assay scales on two substrates, so the numbers are not two spellings of one activity and do not convert by a factor.
Two units, two substrates
The table sets out what each name measures. The entries are not ranked: a unit is not better or worse than another, only more or less suitable for the specification that will verify it.
| Unit | Substrate | Definition in trade use | Detection |
|---|---|---|---|
| FU | Fibrin | Absorbance increase of 0.01 per minute, or 1 µg tyrosine released per minute, or a defined lysis area, depending on the method | 275 nm, tyrosine colour, or fibrin plate |
| IU | Synthetic chromogenic peptide | 1 µmol of p-nitroaniline released per minute at 37 °C | 405 nm |
| U, undefined | — | — | Not comparable to anything |
The last row is not a joke. A figure offered as “20,000 units per gram” with no substrate, no temperature and no detection principle is not a specification; it is a number that will be argued about at goods-in.
FU: a family of methods under one name
The definition most often quoted in trade is an increase in absorbance at 275 nm of 0.01 per minute under the assay conditions. That is the method associated with the Japanese supply chain. Other method sheets define one FU as the release of 1 µg of tyrosine per minute, and a fibrin-plate method defines it by the area of lysis in a given time. The three are related in principle — each measures action on fibrin — but they are separate scales, and a number produced by one is not directly comparable with a number produced by another.
The EU entry names the unit but leaves the numerical definition to the method of Takaoka et al. (2010), which is why a supplier's method sheet, not the unit label, decides what a figure means. The result is reported per gram of preparation as sold, not per gram of protein and not as a purity percentage. The COA page shows where the method belongs on the certificate, and the identity page explains why the unit is one layer of the identity claim.
IU: a synthetic substrate, a narrower claim
One IU is the amount of enzyme that releases 1 µmol of p-nitroaniline from a synthetic chromogenic peptide per minute at 37 °C, read at 405 nm. The substrate is designed around the enzyme's specificity, so the assay is less likely to count unrelated proteases than a fibrin-based method. That is its advantage and its limit: it measures action on a peptide that stands in for the natural substrate, not action on fibrin itself.
An IU figure and an FU figure are therefore answers to different questions. A preparation can be strong on the synthetic peptide and modest on fibrin, or the reverse, because the two assays weigh different parts of the activity. A supplier who reports both is giving two measurements, not one measurement in two units.
Why there is no conversion factor
A conversion factor would need the ratio between the two assays to be constant across every preparation. It is not. Fermentation, recovery and standardisation each change the balance of proteins in the powder, and the two substrates respond differently to that balance. A ratio observed for one preparation belongs to that preparation and that pair of methods; it is not a physical constant.
What does convert is the total number of units within one system. One kilogram at 20,000 FU/g carries 20 million FU; two kilograms at 10,000 FU/g carry the same 20 million FU. That arithmetic is exact and useful for ordering and blend calculations. It says nothing about how FU relates to IU.
When a customer needs a figure in a unit the supplier does not normally report, the answer is a test, not a calculation: ask for the assay to be run on the lot, in the buyer's unit, with the method and the raw result stated. The vocabulary is in the assay glossary entry.
What the label and the specification have to say
The EU novel-food entry states the activity as 20,000–28,000 FU/g and cites the method, so an EU supplement built on that preparation has a defined unit for the specification. A US label may use FU or IU, but the figure has to name the unit and the basis: activity at release, or activity guaranteed at the end of shelf life. The two are different promises, and a label that does not say which one it makes is ambiguous.
An enzyme activity is not a nutrient with a Daily Value, so it does not belong in a nutrition panel as though it had one. The activity lives in the specification and the certificate; the label may state it as a quality characteristic, with the unit. A label that says “IU” over a certificate that reports FU is not a labelling problem to be fixed by arithmetic; it is a specification mismatch.
Which unit to specify
Specify the unit the finished-product specification can verify. For a nattokinase powder dosed into a dry blend, FU/g on fibrin is the practical choice when the supply chain and the certificate are already built around it, because the buyer can compare like with like. Choose IU when the supplier's system is IU-based, when the synthetic substrate is the method the buyer's laboratory runs, or when the narrower specificity of the peptide assay is the point.
Whatever the choice, three things belong beside it: the method reference, the substrate and conditions, and the basis. A specification with those three can be tested at goods-in; one without them can only be discussed. The grade options are compared on the grades page, and the catalog figures are on the nattokinase product page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation