What the COA for lipase actually contains
The certificate for a lipase lot (CAS 9001-62-1) reports activity in LU per gram, the assay conditions behind that figure, appearance, pH, loss on drying, particle size, the heavy-metal panel and microbiology. Each line needs a method and a release limit, because a lipase number is not comparable until the substrate, the pH and the temperature are known. The values below are the catalog specification; the batch COA is the document that confirms a particular drum.
The certificate has to show the unit, the assay substrate, the release limit and the lot result; an activity figure without those four is not a specification.
The certificate as a test report
A lipase COA is a test report before it is a commercial document. For every parameter the reader needs three things: what was measured, which method produced the number, and the limit the lot was released against. A certificate that lists results without the method cannot be reproduced by a second laboratory, and a result that repeats the specification range is not a result at all.
| Parameter | Method | Release limit |
|---|---|---|
| Lipase activity | Titrimetric, tributyrin emulsion, pH 7.0, 30 °C | ≥100,000 LU/g |
| Appearance | Visual | Off-white to light tan, free-flowing powder |
| pH (1% solution) | Potentiometry | 7.0–7.5 |
| Loss on drying | Gravimetric | ≤8.0% |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤10,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
Two rows deserve a second look. The activity row should carry the unit definition, not only the number, because LU is an assay result rather than a mass. The microbiology row should name the tests and the sample size; “absent” without a method is a word, not a finding.
What the LU figure measures
One LU is the amount of enzyme that releases one micromole of titratable butyric acid per minute from a tributyrin emulsion at pH 7.0 and 30 °C. That is a rate, not a weight: it says how fast the preparation splits the substrate under those conditions, not how much enzyme protein the powder contains. A preparation at 100,000 LU/g carries 100 LU per milligram, and the same enzyme diluted on a carrier can sit at a tenth of that figure without any change in the molecule.
The activity basis matters as much as the number. An as-is figure includes the water measured by loss on drying; a dried-basis figure does not. With a loss on drying of up to 8.0%, the two bases can differ by about 8%, which is a material difference when two certificates are compared. The certificate should print the basis and the loss-on-drying result on the same page.
Specific activity, expressed as LU per milligram of protein, is a different and often more revealing number. It is not usually printed on a food-enzyme certificate, but it is the number to request when two concentrates are compared, because it separates more enzyme from more carrier.
Release limit versus batch result
The release limit is the acceptance boundary for the lot; the batch result is what the laboratory measured. Both belong on the page, in separate columns, with the method beside them. A result column filled with the specification range is a copy of the gate, not evidence that the gate was passed.
Activity is a one-sided limit. One lot can sit just above the limit and another well above it; both pass, but the difference changes how much powder goes into a blend and how uniform that blend will be. Loss on drying, heavy metals and microbiology are ceilings; pH and particle size are windows, and a result at either edge deserves the raw data.
“Conforms” is a conclusion, and the reader should be able to reach it from the numbers. When an activity result sits close to the limit, ask for the titration record: sample weight, blank, titre, calculation and the standard used. That record is what separates a measured result from a typed one.
What moves between batches
Activity moves with the fermentation: the Candida rugosa strain, the medium, the induction strategy, the harvest point, the recovery yield and the drying step all shift the titre. Standardisation to 100,000 LU/g is itself a blending step, in which a higher-activity concentrate is cut with carrier until the label is met. The activity can therefore sit exactly on the label while protein content, colour, loss on drying and side activities move from lot to lot.
Colour and odour are less quantitative and often more revealing. A darker tan or a stronger fermentation note can follow a longer fermentation or a warmer drying step while the activity assay still passes. Loss on drying follows the dryer and the packing; particle size follows the mill and the sieve. None of these is captured by the activity figure alone.
A trend across lots says more than a single result near an edge. Loss on drying climbing, activity sitting at the floor and colour darkening together describe a process drifting, even when every individual certificate passes.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a disputed activity result or a method mismatch between supplier and customer. The useful panel is not a full repeat: activity by the customer's method, protein content, SDS-PAGE, microbiology and the heavy-metal panel, all on one submitted sample.
An outside LU number is only comparable if the laboratory used the same substrate, pH, temperature and titration. Change the substrate and the number changes for reasons that have nothing to do with the lot. Ask the laboratory to report the assay conditions and its detection or reporting limits alongside the result.
For a dispute, give the referee the retained sample, the supplier's certificate and the specification, and ask both laboratories for the raw titration, the sample weight, the blank and the standard. Chain of custody matters: the sample tested should be the sample retained, and the lot code should appear on all three documents.
What to compare between suppliers
Put six lines side by side: unit definition and assay conditions; activity result and basis; species and strain; carrier or diluent; loss on drying and microbiology; SDS and allergen statement. Two quotations that both say 100,000 LU/g can describe two different assays, two different bases and two different preparations.
The unit is the first line to compare, not the last. The specification on the lipase product page fixes the catalog position; the grade page explains what a dilution changes, the identity page sets out the activity and protein evidence, and the LU versus FIP note explains why a second unit cannot be read across. The release workflow behind the certificate is described on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation