100,000 LU/g or a dilution: choosing a lipase grade
Lipase is supplied as a 100,000 LU/g powder, as a lower-activity dilution on a declared carrier, and as a granulated powder. The grade changes the activity per gram, the weight the formula has to carry, the dust in the room and the words on the label; it does not change the enzyme. The highest number on the sheet is not automatically the right grade.
The grade is chosen by the activity the process needs and the weight the formula can carry, not by the highest number on the sheet.
Why activity concentration is a grade decision
Three variables sit behind one grade name: activity per gram, physical form and the carrier. A 100,000 LU/g powder is a concentrate, so a small inclusion carries the activity the formula needs. A dilution spreads the same enzyme over more carrier, which makes a small dose easier to weigh and disperse but adds mass that has to be declared. Granulation changes flow and dust without changing the activity definition.
The trade-off is arithmetic. If a formula needs a fixed number of LU per serving, a lower-activity grade needs proportionally more powder. That extra powder has to fit the capsule, disperse in the stick pack or pass through the blender without segregating. The grade decision is therefore a mass-balance decision before it is a purchasing decision.
The grades side by side
| Grade | Activity | What it is | Fits | Watch |
|---|---|---|---|---|
| Powder, 40 mesh | ≥100,000 LU/g | Concentrate; carrier as declared on the COA | Capsules, tablets and blends with a small inclusion | Dust, static and weighing accuracy at small doses |
| Dilution | Agreed in the specification | Base powder on a declared carrier | Stick packs, sachets and blends that need more mass | Carrier identity and amount; blend uniformity |
| Granulated | Same definition as the base | Agglomerated powder | Tablets, sachets and rooms where dust is the problem | Heat and moisture added by the granulation step |
The table is deliberately short. A lipase grade is not a different enzyme, a different source or a different unit; it is the same activity definition presented at a different concentration and particle structure. Any offer that changes the source or the unit is a different material, not a grade.
What changes in the drum
The catalog powder passes 40 mesh, which is about 425 µm. That is a fine, free-flowing powder with a pale colour and a tendency to raise dust when poured. The dust is not only a housekeeping issue: enzyme powders are respiratory sensitisers, so a grade that generates less airborne dust can be worth more to the room than a higher activity figure is to the formula.
Granulation improves flow and reduces dust, but it adds a process. The binder, the water or solvent, the drying temperature and the milling after granulation all have to be declared, and the activity has to be measured after the step rather than assumed from the base powder. A granulated grade with good flow and a measurable activity loss is a worse grade than the powder it came from.
A dilution changes the particle-size distribution as well as the activity. The carrier may be finer or coarser than the enzyme powder, and the two can separate in a blender or a hopper. Ask for the particle size of the blend, not only of the enzyme, and check the uniformity of a trial blend rather than the assay of a single scoop.
What changes in the finished product
For capsules, the fill weight is the limit. The 100,000 LU/g grade lets a small capsule carry the target activity without a large plug of carrier. A dilution is the better choice when the activity target is low and the capsule is large, because the extra mass improves weighing accuracy and fill uniformity.
For stick packs and sachets, dispersion and mouthfeel matter as much as activity. A dilution can reduce the sticky, clumping behaviour of a concentrated enzyme powder and make the single-serve pack easier to empty. The carrier then appears in the ingredient list, and a project that has promised a carrier-free label cannot use that grade.
For tablets, flow and compression decide. A granulated grade can run where a fine powder would bridge in the hopper, but the compression step and any aqueous coating add heat and water that the activity may not survive. The grade choice and the process choice are one decision, not two; the stability page sets out where the losses occur.
For an enzyme blend, the grade has to match the other components. A lipase at 100,000 LU/g and a protease at a different activity per gram are weighed in different amounts; switching the lipase to a dilution changes the blend ratio and may change the uniformity of the minor component.
What to put in the specification
- “Lipase (triacylglycerol lipase, EC 3.1.1.3) from Candida rugosa, ≥100,000 LU/g.”
- “One LU = 1 µmol titratable butyric acid released per minute from tributyrin at pH 7.0 and 30 °C; conditions printed on the COA.”
- “Activity basis as-is; loss on drying ≤8.0%.”
- “Carrier identity and inclusion declared on the COA; the concentrate and the dilution are separate specifications.”
- “Particle size ≥95% through 40 mesh; granulated grade to the agreed size.”
- “Activity measured after granulation, not only on the base powder.”
A line that reads only “lipase 100,000 LU/g” leaves the assay, the carrier and the physical form open. The specification should be written so that a second laboratory could reproduce the number and a second blender could reproduce the blend.
When not to change grade
Do not dilute a grade whose label already declares 100,000 LU/g; the label and the certificate would then describe different materials. Do not granulate a powder that already flows, because the added heat and moisture are a real activity risk for no gain. Do not choose a dilution to save weighing time if the carrier is excluded by the label or by the customer's specification.
Do not chase the highest activity either. A very high-activity powder can be difficult to weigh accurately at a small inclusion, and the dust load in the room rises with the concentration. The right grade is the one that delivers the activity with the least process risk, not the one with the largest number on the front of the specification.
The catalog position is on the lipase product page. The release parameters are on the COA page, the unit definitions are compared on the LU versus FIP page, and the minimum order and packing options are on the MOQ page.
In this document
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation