03 Stability

Lipase activity falls with heat and moisture; the process decides the shelf life

Technical document 03 · Reviewed 2026-11-19 · Lipase

On this page
  1. The dry powder
  2. In solution
  3. What drives the loss
  4. A stability protocol that answers the question
  5. Formulation and processing
  6. Assigning the shelf life

Lipase is a protein, and heat and water change its shape in ways that do not reverse on cooling. A sealed, dry powder at a moderate temperature holds its activity for a long time; a water-based granulation, an aqueous coating, a warm drying step or a permeable pack can remove a large part of it before the shelf life begins. The process, not the molecule alone, decides how much activity reaches the consumer.

In one line

A sealed, dry powder holds its activity; heat, water and the process step are what take it away.

The dry powder

In a dry powder, molecular mobility is low and the enzyme is largely inactive. The two variables that matter are temperature and water activity. Loss on drying is the number on the certificate, with a catalog limit of ≤8.0%, but water activity is the better predictor of stability: a powder that reads 7% moisture can still be safe if the water is tightly bound, and a powder at 5% can fail if it is stored in a humid room.

Keep the powder sealed, cool and dry: a closed foil pouch with a desiccant, below about 25 °C and out of direct sunlight. Refrigeration is not required and brings a condensation risk; if a pack has been cold, let it reach room temperature before opening.

Freezing is not a storage solution: a freeze-thaw cycle can aggregate the protein and reduce activity. If a sample must be frozen, freeze it once, keep it sealed and thaw it fully before assay.

In solution

Once the powder is dissolved, the enzyme becomes active and the clock starts. The preparation may contain residual proteases and other proteins from the fermentation, and those can attack the lipase itself. Activity in a dilute aqueous solution typically falls within hours at room temperature, faster at higher temperature and faster still if the solution is foamed or sheared.

The catalog pH of 7.0–7.5 for a 1% solution is close to the working optimum for a Candida rugosa lipase. Moving away from that window, in either direction, reduces the rate and can also reduce stability. A buffer at the working pH is better than unbuffered water. A solution held for more than a short run needs its own preservation and stability data, because microbial growth is as much a risk as inactivation.

If the process needs a liquid stage, prepare it shortly before use, keep it cool, avoid foaming, and measure the activity at the start and end of the run.

What drives the loss

Stability factors · what changes the activity
FactorEffectControl
HeatDenaturation above the working range; loss is not recovered on coolingKeep drying, granulation and coating temperatures low; measure after the step
WaterMobility and hydrolysis; caking and microbial growth at high water activitySealed pack with desiccant; dry excipients; low-water granulation
pHActivity and stability fall outside pH 7.0–7.5Buffer the liquid stage; check the finished matrix
Shear and foamInterfacial denaturation at the air–liquid boundaryLow-shear mixing; avoid over-mixing; defoam gently
Metal ions and oxidantsProtein oxidation and aggregationCheck excipient quality; avoid incompatible minerals in the same phase
Carrier and reducing sugarsBrowning and protein modification under heat and moistureChoose a low-reducing-sugar carrier; keep the blend dry
PackagingMoisture vapour and oxygen ingressFoil or high-barrier laminate; sealed liner; desiccant where the pack allows

The factors act together: a warm, humid granulation is more damaging than either condition alone, and a reducing sugar adds a third path when the protein reacts with it under heat and moisture.

A stability protocol that answers the question

A useful stability programme tests the material in the pack and the form in which it will be sold, not only the powder in a laboratory jar. Start with a retained sample of the lot, store it in the commercial pack at 25 °C/60% RH and at 30 °C/65% RH, and pull samples at 0, 1, 3, 6, 12 and 24 months. Assay activity, loss on drying and appearance at each point.

Accelerated storage at 40 °C/75% RH is useful for screening a new formulation, but it is not a substitute for real-time data at the label condition. Enzyme inactivation is not a simple first-order reaction across a wide temperature range, so an Arrhenius extrapolation from a hot cabinet can overstate the shelf life. Use the accelerated result to rank formulations, and the real-time result to assign the shelf life.

Test the finished form as well: the tablet, the stick pack or the blend, not only the powder. The additional excipients, the water activity of the mix and the compression step can each change the loss rate. The acceptance criterion should be the minimum activity at the end of the shelf life, not the release activity.

Formulation and processing

Granulation is the step most likely to damage the enzyme. If the lipase is added to the granulation water, it is in solution for the duration of the wet step and the drying step; the loss can be substantial. The safer route is to granulate the other components, dry them, and add the enzyme as a dry powder in the final blend. Dry binders and roller compaction generate less water exposure than a wet granulation, though the rolls can still get warm.

Tableting adds pressure and local heat. Direct compression is usually gentler than a heavily worked wet granulation, but the die temperature and the dwell time still matter. Measure the activity in the finished tablets, not only in the blend, and compare it with the activity that went into the press.

Aqueous film coating is another water source; if the tablet core contains the enzyme, a low-water or solvent-based system is easier on the activity. In a stick pack, the laminate barrier and the water activity of the powder decide the shelf life, because a single-serve pack cannot hold a desiccant sachet.

Assigning the shelf life

Shelf life is a property of the pack and the storage condition, not of the molecule. The assigned figure belongs on the TDS and should be supported by real-time data for the grade, the pack and the storage condition. Dry enzyme powders in sealed foil are commonly given shelf lives measured in years; a diluted or granulated grade, a stick pack or a warm-market pack can be shorter, and the customer's pack may be shorter again.

State the storage condition with the number: a duration, a temperature and a pack condition are testable; “store in a cool, dry place” is not. State the activity at the end of the shelf life, not only at release. An overage used to meet the end-of-life figure is a formulation choice, not a stability result, and has to be declared and supported.

The release parameters are on the COA page, the packaging and order details are on the MOQ page, the grade options are on the grade page, and the release workflow is described on the quality page. The catalog position is on the lipase product page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation