LU vs FIP: what a lipase unit actually means
LU and FIP are both lipase activity units, but they come from different assays: LU is normally titrated on tributyrin at pH 7.0 and 30 °C, while FIP is titrated on olive oil at pH 9.0 and 37 °C. The numbers are not interchangeable, and no fixed factor converts one into the other. Only a side-by-side assay on the same lot can put the two units on the same page.
LU and FIP are different assays before they are different numbers; without the substrate, pH and temperature, neither unit identifies a lipase.
Two definitions
| Unit | Substrate | pH | Temperature | Definition |
|---|---|---|---|---|
| LU | Tributyrin emulsion | 7.0 | 30 °C | 1 µmol titratable butyric acid released per minute |
| FIP | Olive oil emulsion | 9.0 | 37 °C | 1 µmol (microequivalent) fatty acid released per minute |
| “U” or “IU” | Defined by the laboratory | Not fixed | Not fixed | No fixed meaning until the method is named |
LU is the unit used in the food-enzyme trade, and the tributyrin titration is its common form. FIP is the unit associated with the pharmacopoeial lipase method and with fungal lipase standards; the FIP method is tied to a standard preparation, which is why two laboratories using it can be compared. A bare “unit” on a specification is neither: it is a placeholder until the method is written down.
Why the substrate changes the number
Lipase acts at the interface between oil and water, not in a homogeneous solution. Tributyrin is a short-chain triglyceride and olive oil is a long-chain mixture; the two form different interfaces, with different droplet sizes and different accessibility to the enzyme's active site. The emulsifier, the homogenisation speed and the age of the emulsion all change the surface area the enzyme sees.
The rest of the method moves the number too. pH 9.0 is well above the pH 7.0 used in the LU assay, and it changes both the charge on the protein and the ionisation of the fatty acid being titrated. Thirty-seven degrees is faster than thirty. A longer incubation can exhaust the emulsion or allow product inhibition. The same preparation can therefore give a respectable LU figure and a modest FIP figure, or the reverse, without anything changing in the drum.
This is why a unit is a property of the assay as much as of the enzyme. The substrate, the pH, the temperature, the time, the detection and the standard are all part of the definition. Leave one out and the number floats.
The conversion problem
There is no general conversion factor between LU and FIP. A factor that works for one preparation, one pair of methods and one laboratory does not transfer to another, because the two assays respond differently to the same change in substrate, pH and temperature. A supplier may quote a factor, but it is a result of a particular comparison, not a property of the units.
| Variable | LU | FIP | Effect on the number |
|---|---|---|---|
| Substrate | Tributyrin | Olive oil | Different interface and chain length; not proportional |
| pH | 7.0 | 9.0 | Different activity and different titration endpoint |
| Temperature | 30 °C | 37 °C | Faster reaction at the higher temperature |
| Standard | Supplier method | Standard preparation | Different anchor for the unit |
If a customer needs FIP, assay the lot by FIP. A conversion printed on a certificate, without the raw data for both methods on the same lot, is not evidence; it is an assertion. The honest line is a result in the unit the customer's method produces, with the conditions attached.
What belongs on the label and the specification
The unit on a specification or a pack has to be defined, not just named. “Lipase ≥100,000 LU/g” is a complete statement only when the LU definition and the assay conditions sit beside it. “Lipase 100,000” without a unit is not a specification at all, and “100,000 LU/g equivalent to FIP” is a claim that needs data behind it.
FIP and LU also carry different expectations. FIP is the language of pharmacopoeial and pharmaceutical work, where the method and the standard are part of the quality system. LU is the language of food-enzyme supply, where the customer's quality laboratory often runs its own titration. Neither is better; they answer different questions, and the market and the customer's method decide which one belongs in the contract.
For EU, US and UK food-enzyme files, the activity statement is a technical description of the preparation. It is not a health claim, and a change of unit does not change the regulatory status of the material. The unit has to match the method used in the destination market's file, and the method has to be reproducible by the customer's laboratory.
When to choose which
| Situation | Unit to use |
|---|---|
| The customer's quality laboratory already runs a tributyrin titration at pH 7.0 | LU, with the conditions written into the specification |
| The customer's specification or pharmacopoeial method is olive oil at pH 9.0 | FIP, reported by the FIP method |
| Two lipases are blended and the ratio has to be fixed | One unit system for both components, never a mix |
| An existing label or contract already declares a unit | Keep that unit; do not switch silently |
| A new product with no legacy method | The method the contract laboratory runs, named in the specification |
The choice is usually made by the customer's method, not by the supplier's preference. A supplier who can report only the other unit should be asked for a lot-specific side-by-side result, not for a conversion factor.
How to verify a conversion claim
Ask for the same lot run by both methods, in the same laboratory, against the same standard, with replicates and the raw titration data. The report should name the substrate, the emulsifier, the pH, the temperature, the reaction time, the detection method and the standard. Without those, a conversion is a number about a method, not about the material.
The catalog position is on the lipase product page; the grade options are on the grade page, the certificate lines are on the COA page, and the identity evidence is on the identity page. The assay conditions are also defined in the assay glossary entry.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation