What a keratinase COA has to show beside the U/g figure
A keratinase certificate lists appearance, activity, identity, moisture, the heavy-metal panel, microbiology and particle size. The activity line deserves the closest reading: its U/g value depends on a keratin-substrate assay, and the substrate, pH, temperature and unit definition are not the same in every laboratory. The limits below are the catalog specification; the batch document confirms one pack.
A keratinase figure is only an activity when the substrate, the assay pH and the unit definition are printed beside it.
The certificate as a test report
Each row should be readable on its own: the parameter, the method that generated the value, and the acceptance limit. A bare “conforms” hides all three. The activity row adds a fourth item, the unit definition, because a keratinase U is not a fixed quantity.
Keratinase is a functional name: it covers a group of proteases that attack keratin rather than one molecule with a single registry entry. Identity therefore rests on the declared organism and on the assay, and the lot code connects the document to the pack.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Off-white to light tan, free-flowing powder |
| Activity | Keratin-substrate assay; substrate, pH, temperature, time and unit definition printed | ≥50,000 U/g |
| Identification | Activity assay conform | Conforms to the reference |
| Loss on drying | Gravimetric | ≤8.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
An activity-conform identity line is thin evidence by itself. It shows a response, not the protein. Ask for the source declaration and the protein profile as well; the identity page explains what each one adds.
As-is, dried basis and the unit definition
The assay reads the powder as it arrives and reports units per gram of that powder. Converting to dry solids is a division: 52,000 U/g at 6.0% moisture becomes 52,000 ÷ 0.94 = 55,319 U/g on dried solids. Both figures are valid, but a buyer and a supplier who use different denominators are not comparing the same number.
Unit definitions vary more than the arithmetic. In one keratin-azure method, a unit is the activity that lifts absorbance at 595 nm by 0.01 in an hour; in another, a unit releases a micromole of dye in a minute. The same 50,000 U/g label can therefore describe very different rates. The certificate should print the substrate, pH, temperature, incubation time, standard and calculation, and the method sheet should be available before the first order.
Keratin does not dissolve like casein. The substrate is particulate and heterogeneous, so shaking, particle size and time change the release of dye or peptide. A method transferred to a second laboratory needs a correlation run on the same substrate, not an assumption that the unit is portable.
The floor, the result and the shelf-life question
≥50,000 U/g is a floor, not a target. Two compliant lots, one at 51,000 and one at 90,000, will behave differently where the process consumes activity. Read the measured value, and ask whether it refers to release or to the end of the retest period.
| Parameter | Limit | Result column |
|---|---|---|
| Activity | ≥50,000 U/g | A measured figure, with the unit definition and the basis |
| Loss on drying | ≤8.0% | A measured percentage |
| Heavy metals | Per element | A figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
| Particle size | ≥95% through 80 mesh | The measured percentage through the sieve |
Microbiology and metals are not single verdicts: each element and each count has its own result, and “passes” is a claim the reader should be able to verify. Repeatability matters too; a lot barely above the floor is less reassuring when the method's relative standard deviation is wide.
Where lot-to-lot spread comes from
Three operations move the number: fermentation, recovery and standardisation. The fermentation sets which proteins are made; the recovery decides how much survives; the carrier fixes the final units per gram. A change in any one of them can shift the activity without a change in the name.
Colour is a weak indicator. A darker tan may reflect drying or hold time while the assay is unchanged. The stronger record is the lot code shared by certificate, pouch, drum and retained sample.
When an outside assay is warranted
An outside assay is worth ordering for a new source, a first consignment for a regulated use, a disputed figure, or a method the supplier does not run. Keep the panel focused: the named keratin assay, protein by a stated method, moisture, metals, microbiology, and a casein assay if the keratin-to-casein ratio matters.
Send the method sheet with the sample. The laboratory needs the substrate, the definition and the calculation, not just a target. Ask for the limit of detection and the repeatability beside each result; a “not detected” without a limit describes the method's reach, not the sample's purity. For a dispute, the retained sample, the original certificate and the specification should go to the referee together.
What to compare between suppliers
Compare six things: the declared organism and strain; the activity with its definition and basis; moisture; metals and microbiology; particle size; and the pack with its lot code. Offers that match on 50,000 U/g but differ on substrate or definition do not describe the same activity.
Traceability is the second layer: manufacturer, fermentation and recovery, carrier, and the change record. The catalog limits are on the keratinase product page; the grades page covers form and concentration; the identity page covers source and protein; the neutral protease pages show a soluble-substrate certificate; the methods index leads to assay notes; the quality page covers release.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.