What the COA for bromelain actually contains
For a bromelain lot the certificate reports appearance, activity in GDU/g with the assay method, pH of a 1% solution, loss on drying, particle size, the heavy-metal panel and microbiology. Activity is the number that decides whether the powder is the grade ordered, and it is also the number most easily quoted without the conditions that produced it. The ranges are the catalog specification; the batch COA confirms a particular drum.
The GDU figure is an assay result on a named substrate, not a concentration, so the unit, the gelatin method and the conditions belong beside it.
The certificate as a set of rows
Read the sheet as rows, each carrying a test, a method and a limit. Activity is the first row a buyer checks, but moisture, pH and the heavy-metal panel can each fail while activity looks correct. A certificate that reports a number without a method cannot be reproduced by a second laboratory.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Off-white to light tan powder |
| Bromelain activity | Gelatin digestion, GDU method | ≥2,400 GDU/g |
| pH (1% solution) | Potentiometry | 5.0–7.0 |
| Loss on drying | Gravimetric | ≤5.0% |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Parameter | Method | Release limit |
|---|---|---|
| Lead (Pb) | ICP-MS | ≤3 mg/kg |
| Arsenic (As) | ICP-MS | ≤2 mg/kg |
| Cadmium (Cd) | ICP-MS | ≤1 mg/kg |
| Mercury (Hg) | ICP-MS | ≤0.1 mg/kg |
| Total aerobic count | Plate count | ≤10,000 cfu/g |
| Yeast and mould | Plate count | ≤100 cfu/g |
| E. coli | Absence test | Absent |
| Salmonella | Absence test | Absent |
What the GDU figure measures
GDU stands for gelatin digesting unit. One GDU is the amount of enzyme that liberates 1 mg of amino nitrogen from gelatin in 20 minutes at 45 °C and pH 4.5. The result is a rate on a named substrate, so a declared activity of ≥2,400 GDU/g means that every gram of powder, as sold, carries at least that activity under those conditions. It is not a purity percentage and it does not translate directly into protein content.
Activity is reported per gram as-is, which is why the moisture row sits beside it. A lot at the 5.0% loss-on-drying limit carries more water per gram than a lot at 2.0%; if the dry solids hold the same activity, the as-is GDU/g of the wetter lot is lower. The two numbers have to be read together, and the activity basis — as-is or dried — should be stated on the certificate.
The pH row is measured on a 1% solution and sits at 5.0–7.0. That is not the pH of the activity assay, which is 4.5. A powder can sit inside the solution-pH range and still be assayed at a pH the solution does not hold. The mesh row is a sieving result: ≥95% through 40 mesh describes fineness, not activity, and a change of mesh needs a new sieve result rather than a new activity figure.
Release limit versus batch result
A limit is the gate; a result is what the laboratory measured. They belong in separate columns, with the method beside them and the lot number above them. A result column that repeats the limit is not a result; it says what the lot was allowed to be, not what it was.
The activity limit is one-sided. A lot at 3,000 GDU/g is not out of specification because it is far above the floor; it is a stronger lot of the same grade, and the buyer should decide whether the higher activity suits the formula. A lot at 2,390 GDU/g fails the floor even if every other row passes. Rounding matters: a result given to the nearest 50 GDU/g against a limit of 2,400 leaves an ambiguous band, so fix the reporting resolution and the acceptance rule.
Not every row is a measurement. Appearance is an observation and “conforms” is a judgement. The heavy-metal and micro rows do carry numbers and should be reported against the same limits as the specification. When a result sits at the limit, ask for replicates; one value at the boundary is less informative than three around it.
What moves between batches
Bromelain is extracted from pineapple stem, so the raw material is agricultural before it is enzymatic. Cultivar, harvest, stem handling and the time between cutting and extraction all reach the final powder. The purification train — clarification, precipitation, drying and milling — then sets how much activity survives into the drum.
Dilution is the largest single lever on the activity figure. A 1,200 GDU/g grade is normally the same preparation blended with a food-grade carrier to a lower activity per gram, not a different enzyme. If the certificate does not name the carrier or the dilution step, two quotations for the same grade may not describe the same powder.
Colour is a weak signal. A darker tan can follow a hotter drying step or a longer hold, and both can lower activity. pH drifts with neutralisation and drying; loss on drying moves with the drier and the pack. None replaces the activity assay, but a trend across lots is worth a question.
When to order an outside test
An independent test is worth ordering for a new source, the first shipment into a regulated market, a disputed result, or an activity figure that does not match the trial. The panel should repeat the activity assay with the same substrate and conditions, add protein content and a protein band pattern, and run ICP-MS plus microbiology on the same submitted sample.
Ask the laboratory to state the substrate, the standard, the incubation time and the replicate results, not only the final number. The GDU assay has several published versions and several in-house modifications; two laboratories can report different figures for the same powder because their gelatin, pH or endpoint differs. A “not detected” line without a detection limit is a statement about the method, not the sample.
Chain of custody matters: the sample tested should be the sample retained, with the lot code on the bag, the certificate and the submission form. If a result is contested, the referee should receive the supplier's certificate and the specification before it starts, so the disagreement is about the measurement rather than the paperwork.
What to compare between suppliers
| Line | What to ask for |
|---|---|
| Source | Pineapple stem, botanical name and country of origin |
| Activity | GDU/g, with the result and not only the limit |
| Method | Substrate, pH, temperature, time and standard |
| Basis | As-is or dried, with the loss-on-drying result |
| Physical | pH of a 1% solution and the mesh result |
| Contaminants | Heavy-metal and microbiological results against limits |
| Carrier | Diluent, granulation aid or other enzyme activity declared |
Two quotations that agree on GDU/g but disagree on the method, the basis or the carrier are not the same material. The catalog specification for this grade sits on the bromelain product page; the activity choice is set out on the grade page; the tests behind the identity claim are on the identity page; the heavy-metal method is described in the ICP-MS note; the terms on the certificate are defined in the COA glossary entry.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation