01 COA & batch testing

What the L-theanine COA reports, line by line

Technical document 01 · Reviewed 2026-11-20 · L-Theanine

On this page
  1. The certificate, row by row
  2. Assay basis, the rotation and the L/D question
  3. The limit and the measured result
  4. Lot-to-lot variation
  5. When an outside test earns its place
  6. Comparing two offers

An L-theanine certificate reports appearance, identity by HPLC retention and infrared spectrum, assay by HPLC at 98.0–101.0%, specific rotation at +7.5° to +9.0°, loss on drying at ≤0.5%, the heavy-metal panel, microbiology and particle size. The assay and the rotation answer different questions: the first measures how much theanine is present, the second confirms that it is the L-enantiomer. The limits below are the catalog specification; the batch certificate is the record for one particular pack.

In one line

The assay measures the amount of theanine; the specific rotation measures which enantiomer it is, and a certificate needs both.

The certificate, row by row

A certificate earns its place when each row states the parameter, the method and the release limit, and leaves a separate column for the measured result. For L-theanine the two rows that decide identity are the chromatographic identification and the specific rotation. A certificate that reports only an assay percentage has measured the quantity and left the enantiomer untested.

The infrared spectrum and the HPLC retention time identify the molecule; the rotation identifies the enantiomer; the assay measures the content. Those are three questions, and one number cannot answer all three.

Identity, assay and purity limits · L-theanine
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationHPLC retention and infrared spectrumBoth conform to the reference
AssayHPLC98.0–101.0%
Specific rotationPolarimetry, c=2 in water+7.5° to +9.0°
Loss on dryingGravimetric≤0.5%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

Assay basis, the rotation and the L/D question

The assay needs a basis. The laboratory measures the powder as received; the result is then expressed either as-is or on the dried basis. The specification should say which, and the loss on drying should sit beside the assay as a measured figure. The arithmetic is small but not zero: a lot at 99.0% as-is with 0.5% loss on drying is 99.5% on the dried basis (99.0 ÷ 0.995). A result and a limit stated on different bases are not directly comparable.

Specific rotation is concentration-normalised, so it does not fall when the sample is cut with a non-optical carrier. A low rotation means the D-enantiomer or another optically active impurity is present, not that the powder is weak. The catalog window is +7.5° to +9.0° at c=2 in water; a value inside it is consistent with the L form, and a value outside it is a reason to ask for chiral HPLC rather than to repeat the polarimeter.

Chiral HPLC is not on the catalog specification, but it is the quantitative enantiomer test. Ask for the L and D area percentages when the label, the market file or a previous lot makes enantiomer purity part of the agreement. The rotation and the chiral result should agree; if they do not, the sample preparation or the concentration is the first thing to check.

The limit and the measured result

A release limit is the boundary; the batch result is the measurement. They need separate columns, and the method has to be named beside them. When the result column simply repeats the specification range, the reader has been given the boundary twice and the measurement not at all.

What the result column should contain
ParameterRelease limitResult column
Assay98.0–101.0%A measured percentage, with the basis stated
Specific rotation+7.5° to +9.0°The measured angle, the concentration and the solvent
Loss on drying≤0.5%A measured percentage
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot
Particle size≥95% through 80 meshThe measured percentage through the sieve

Read the identity row the same way. “Conforms” is the reviewer's conclusion; the spectrum and the retention time are what the conclusion rests on. A certificate that shows a retention time but no spectrum has tested one dimension of identity and left the other to trust.

Lot-to-lot variation

The source route sets the impurity fingerprint. A tea-derived lot starts from an extract that also contains caffeine and polyphenols, so the purification record and the caffeine question belong with the certificate. A fermentation or enzymatic lot starts from a broth, so residual media, related amino acids and the enantiomer ratio are the lines to watch. The assay can pass in both cases while the trace profile differs.

Drying moves the loss on drying and the as-is assay. Milling moves the particle-size result: 80 mesh is a finishing specification and can change when the mill or the sieve changes, without any change in the chemistry. Colour is a weak signal, because white to off-white covers a wide window, but a batch that is noticeably darker or duller is worth a question.

The rotation should be stable across lots of the same enantiomer grade. A drift towards the low end of the window is the one variation that points at identity rather than at finishing, and it should be investigated with chiral HPLC before the lot is released against a label that names the L form.

When an outside test earns its place

Order an independent test for a new source, a first shipment into a regulated market, a disputed rotation, or a label that depends on the enantiomer. The useful panel is not a full repeat of the certificate: HPLC assay with the chromatogram, infrared spectrum, specific rotation, chiral HPLC for the L/D ratio, loss on drying, ICP-MS for the metals and the microbiology set. Add a caffeine screen when the lot is tea-derived and the specification does not already limit it.

Make the laboratory state its detection limit for every screen. Without that figure, a “not detected” entry says more about the method than about the powder. Chain of custody matters as well: the sample tested should be the retained sample, and the report should carry the lot code that appears on the pouch or drum.

Comparing two offers

Put seven lines side by side: name and CAS number; source route; assay result and basis; specific rotation with concentration and solvent; chiral HPLC result if available; loss on drying and particle size; heavy metals, microbiology and documents. An offer that matches on assay but differs on rotation or source route describes a different powder.

Traceability is the second layer: the manufacturer, the route, the drying and milling steps, and the revision of the specification under which the lot was made. The product hub carries the catalog specification; the identity page sets out the evidence behind the rotation; the grades page covers the source route; the HPLC method note describes the separation, and the quality page describes the release workflow.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation