L-ornithine vs L-ornithine HCl: chloride, pH and the label
The hydrochloride is the free base plus one equivalent of hydrochloric acid. It is 168.62 g/mol against 132.16, carries about 78.4% ornithine and 21.0% chloride, and dissolves to an acidic solution rather than an alkaline one. The label has to name the salt, and the quantity has to say whether it refers to the salt or to the ornithine.
One hydrochloride adds 36.46 g/mol, and with it an acidic solution, 21.0% chloride and a different name and number for the label.
One proton and one counter-ion
Ornithine has a carboxyl group and two amino groups. The free base is the neutral molecule, C5H12N2O2, 132.16 g/mol. The monohydrochloride adds one HCl across the molecule: C5H13ClN2O2, 168.62 g/mol, CAS 3184-13-2. The two are separate specification items with separate CAS numbers, and a purchase order that names only "L-ornithine" has not chosen either.
| Property | Hydrochloride | Free base |
|---|---|---|
| CAS number | 3184-13-2 | 70-26-8 |
| Formula | C5H13ClN2O2 | C5H12N2O2 |
| Molecular weight | 168.62 | 132.16 |
| Ornithine per gram | About 784 mg | 1,000 mg |
| Chloride per gram | About 210 mg | None from a counter-ion |
| Solution pH | Acidic | 9.0–11.0 at 1% |
| Label name | L-ornithine hydrochloride | L-ornithine |
The chloride load and the label arithmetic
At 21.0% chloride, the salt brings a real quantity of a nutrient that a label may have to account for. One gram of powder carries about 210 mg of chloride; 500 mg carries about 105 mg; a 1,000 mg ornithine dose, which needs about 1,276 mg of salt, carries about 268 mg of chloride. These figures are arithmetic, not a dose recommendation.
If the label declares chloride, the EU reference intake is 800 mg/day in Annex XIII of Regulation (EU) No 1169/2011, as of this review. One gram of the salt is about 26% of that reference. The nutrition declaration's "salt" figure is a different calculation: it is sodium × 2.5 under Annex I of the same Regulation, and the salt contains no sodium, so its chloride does not raise the declared salt figure. That distinction matters when a panel already carries a salt line from another ingredient.
In the US, the Supplement Facts panel names the dietary ingredient and its amount; a chloride line is a separate labelling decision, not something that appears because the ingredient name ends in "hydrochloride". The buyer's regulatory team records that decision with the label file.
Why the solution turns acidic
The free base solution is alkaline because the amino groups are largely unprotonated; the catalog window is 9.0–11.0 at 1%. The hydrochloride is the salt of that weak base with a strong acid. In water the ammonium group releases a proton, so the solution is acidic, and the pH moves with concentration because the equilibrium depends on how dilute the solution is. The catalog does not print a pH number for the salt, so a formulator who needs one should agree a value at a stated concentration and have it measured on the lot.
The pH change is not cosmetic. An acidic ingredient can shift the pH of a drink, change the colour of a sensitive pigment, alter the gel strength of a protein system or move the taste. It can also change the rate of a reaction with a reducing sugar. The free base moves the same matrix in the opposite direction, so a formula built on one form cannot be switched to the other without rechecking the pH and the hold time.
The conversion a formula needs
The conversion factor is the ratio of molecular weights: 168.62 ÷ 132.16 = 1.276. To declare 1,000 mg of ornithine, weigh 1,276 mg of the salt. To declare 500 mg of ornithine, weigh 638 mg. In the other direction, 500 mg of the salt delivers 392 mg of ornithine, and 1,000 mg of the salt delivers 784 mg. The factor is fixed by the formula, not by the assay.
The assay is a second, smaller correction: a lot at 99.5% as the salt needs slightly more powder than the theoretical conversion, and the loss on drying is a third. The steps are small for this salt because the moisture limit is 0.5%, but they should be applied in the same order and recorded. A capsule fill designed on the raw salt weight and a label written on ornithine are two different numbers.
What the label has to say
Name the form. In the EU, the ingredient is "L-ornithine hydrochloride"; the free-base name does not describe the salt, and the novel-food and member-state review runs on the exact material. In the US, the Supplement Facts panel should write the salt out rather than use "L-ornithine" as a short name for it. The panel and the certificate must name the same substance.
The quantity needs a convention. A panel that says "L-ornithine hydrochloride 500 mg" declares 500 mg of the salt, which is about 392 mg of ornithine. A panel that says "L-ornithine 500 mg (as L-ornithine hydrochloride)" declares 500 mg of ornithine, which needs about 638 mg of the salt. Both conventions can be made consistent, but a bare "L-ornithine 500 mg" filled with the salt overstates the ornithine: 500 mg of the salt carries only about 392 mg, so the panel is short by about 108 mg. Write the form and the reference quantity into the artwork and the specification together.
Ornithine has no EU Nutrient Reference Value and no US Daily Value, so no percentage belongs beside it. The chloride line, if the label carries one, follows the reference intake for chloride. No disease-related claim is open in either market, and the form does not create one.
When to use which form
Use the hydrochloride when the formula wants a less alkaline powder, when the label names the salt, or when the chloride is acceptable or already declared. Use the free base when the label names L-ornithine, when the formula needs the alkalinity, or when the chloride is not acceptable. The salt is not a stronger version of the base and the base is not a purer version of the salt; they are different materials with different masses.
A switch in either direction needs a new specification, a new fill weight, a new label and a stability check. The hydrochloride product page carries the catalog specification; the free-base page carries the other sheet; the grades page places this comparison in the range; the methods library explains the assays; the quality page describes the release file.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation