01 COA & batch testing

What the COA for L-lysine free base actually contains

Technical document 01 · Reviewed 2026-11-20 · L-Lysine

On this page
  1. Reading the release sheet
  2. What the assay is calculated as
  3. Limit and result are different columns
  4. Batch-to-batch drift
  5. Independent testing
  6. Supplier comparison

A free-base L-lysine certificate is shorter than the hydrochloride sheet: appearance, IR, titration, rotation, loss on drying, particle size, metals and micro, with no chloride or pH line. The catalog ranges are 98.5–101.5% for the titration and +25.0° to +27.0° for the rotation at c=2 in 5 M HCl. The ranges are release gates; the lot COA records what a named pack measured.

In one line

The titration states how much lysine is present, the rotation states which enantiomer it is, and the absent chloride line states which form was packed.

Reading the release sheet

Each row should carry the test, the method and the limit it was judged against. A tick alone asks the reader to accept a verdict. The table is the catalog gate, not a batch record.

Catalog release lines · L-lysine free base
ItemHow it is measuredCatalog limit
AppearanceVisualWhite to off-white, free-flowing powder
IdentificationIR and titrationMatches the reference
Assay, as L-lysineTitration98.5–101.5%
Specific rotationPolarimetry, c=2, 5 M HCl+25.0° to +27.0°
Loss on dryingGravimetric≤0.5%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absenceAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve≥95% through 80 mesh

No chloride row appears because there is no counter-ion to measure. A free-base sheet that reports 19.0–19.6% chloride has borrowed the hydrochloride lines, and a certificate that shows chloride and a pH of 5.0–6.0 is describing the salt. The form belongs on the certificate, not only in the product title.

What the assay is calculated as

The titration is expressed as L-lysine, not as the hydrochloride. A result of 99% as the base and a result of 99% as the salt are not the same amount of lysine: the base is the entity, while the salt carries 0.80 g of it per gram. A buyer who applies the molecular-weight factor to a base result is converting a number that is already on the lysine basis.

The certificate should say as-is or dried. At a loss on drying of ≤0.5% the gap is half a point at most, but the basis is part of the result. A wet lot can pass a dried-basis gate while the drum holds less lysine than the label expects.

IR identifies the amino acid; the rotation at c=2 in 5 M HCl identifies the enantiomer. The acid puts the base into solution as the hydrochloride, so solvent, concentration, temperature and wavelength all belong beside the angle. Chiral HPLC is the alternative when the ratio, not the angle, is the question.

Limit and result are different columns

The limit is what the lot had to meet; the result is what it met. Printing the specification range in the result column reports the gate twice and the lot not at all.

What the lot column should carry
TestLimitLot column
Assay98.5–101.5% as the baseA percentage, with basis and method
Specific rotation+25.0° to +27.0°The angle and its conditions
Loss on drying≤0.5%A measured figure
Heavy metalsPer elementA figure per element, in mg/kg
MicrobiologyCounts and absenceThe count plus the absence line
Particle size≥95% through 80 meshThe measured pass percentage

“Conforms” is a verdict, not a measurement. Metals need a figure per element; a total can hide the one that matters. Micro needs a count and an absence statement. Rotation needs the angle and its conditions, or the result cannot be compared with another laboratory's report.

Batch-to-batch drift

Crystallisation and drying leave marks on the assay, the rotation and the water content. The rotation should stay inside the L window; a slide toward zero can mean racemisation or a DL blend. Loss on drying is partly production and partly storage, and the free base is hygroscopic enough that the two blur after a long warehouse stay.

Milling changes the particle-size result without changing the chemistry. The catalog grade passes 80 mesh, about 180 µm; a granulated grade is a separate specification. Colour is the least numerical line and often the first warning: a tan cast can follow an overheated dryer or a trace of iron while the titration stays in range.

A chloride line on a base certificate is a paperwork finding before it is a quality finding. The document should follow the material that was packed.

Independent testing

A new source, a new market, a disputed form claim or a contested result are the usual reasons to go outside. Build the panel around the form question rather than repeating the supplier's sheet.

Titration on a stated basis, rotation with conditions, IR, loss on drying, chloride by ion chromatography or argentometric titration, ICP-MS for the metals and the microbiological set cover the essentials. Chiral HPLC is the add-on when the enantiomer ratio matters. Chloride is the form test: the base should show none, while 19.41% is the hydrochloride's theoretical share.

Every “not detected” needs its detection limit. The laboratory should test the retained sample and quote the lot code on the report. If the result is contested, the referee needs the retained sample, the certificate and the specification, and a request for the tests that separate the forms.

Supplier comparison

Questions that separate two free-base quotations
QuestionWhat to ask forWhy the answer matters
Form and CASL-lysine free base, 56-87-1Separates the base from the salt and from DL-lysine
Assay and basisTitration, as-is or dried, as the baseA salt figure or a salt basis is a different number
RotationAngle and conditionsConfirms L and optical purity
ChlorideResult or absence, with methodShows whether the salt is present
WaterLoss on drying and methodShows the as-is assay and the storage risk
Particle size80 mesh or agreed distributionAffects flow and fill
ContaminantsResults for the lot, against the limitsConfirms the batch met the panel
ChainLot code, maker and retention sampleTies the document to the drum

The product hub holds the catalog specification. The hydrochloride is a separate product on the hydrochloride page. For the analytical evidence, see the identity page; for release, the quality page; for the methods, the methods library.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation