01 COA & batch testing

What the COA for L-glutamine actually contains

Technical document 01 · Reviewed 2026-11-19 · L-Glutamine

On this page
  1. What a certificate has to show
  2. The assay and the dry-mass correction
  3. Gate and measurement are different columns
  4. What drifts from lot to lot
  5. When to bring in a referee
  6. Six lines for a supplier comparison

The certificate for an L-glutamine lot reports appearance, identification by infrared and ninhydrin, the assay by HPLC on the dried basis, specific rotation, loss on drying, residue on ignition, pH, particle size, the heavy-metal panel and microbiology. Each line needs three things: what was measured, which method produced the figure, and which release limit the lot was judged against. The limits shown here belong to the catalog; the lot certificate is what ties a measured result to the drum in front of you. An assay figure on its own does not show that the material is the L form.

In one line

The assay reports how much glutamine is present; the rotation reports the L form, and the water and pH report the state it is in.

What a certificate has to show

A certificate is only useful if each row can be audited without a phone call. The tables below separate the release tests from the contaminant and microbiological panel. A figure needs its method, and a limit needs its basis; without both, the row cannot be checked.

Identity, assay and physical tests · L-glutamine
ParameterMethodRelease limit
AppearanceVisualWhite crystalline powder or flakes
IdentificationInfrared spectrum and ninhydrin reactionConforms
Assay (glutamine)HPLC, dried basis98.5–101.5%
Specific rotationPolarimetry, dried basis+6.3° to +7.3°
Loss on dryingGravimetric≤0.5%
Residue on ignitionGravimetric≤0.3%
pH (5% solution)Potentiometry5.0–6.5
Particle sizeSieve analysis≥95% through 40 mesh
Contaminant and microbiological limits · L-glutamine
ParameterMethodRelease limit
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The assay and the dry-mass correction

The assay is a chromatographic result, not a nitrogen count. Glutamine has no strong chromophore in the usual ultraviolet range, so an HPLC method either detects at a low wavelength or derivatises the amino group before separation. Both approaches can be valid, but the certificate should name the column, the mobile phase, the standard and the detection mode. A Kjeldahl nitrogen result would count other nitrogenous material and cannot substitute for the chromatographic result.

The assay is reported on the dried basis, which means the water has been removed from the denominator. Loss on drying is measured in a separate test, and the correction is arithmetic: assay on dried basis equals assay as-is divided by one minus the loss on drying expressed as a fraction. A lot that reads 99.0% as-is with 0.4% water corresponds to 99.4% on the dried basis. Both can be correct; the basis belongs next to the number.

The 98.5–101.5% window includes the analytical uncertainty of the method. It is not a licence to accept any white powder: an assay inside the window is compatible with the wrong enantiomer, a partly degraded lot or a blend with another amino acid. The rest of the certificate exists to narrow those possibilities.

Gate and measurement are different columns

The release limit is the acceptance boundary chosen for the specification; the batch result is what the laboratory measured on that lot. A certificate that prints the specification range in the result column has not reported a result. One that prints “conforms” reports a conclusion the reader cannot check.

Reading one certificate line
FieldWhat it should containCommon failure
ParameterThe substance and the form, for example L-glutamineA generic “amino acid” label
MethodThe technique and the detection principle“HPLC” with no column or standard
Release limitThe range or maximum used at releaseA limit copied from a different grade
ResultThe measured figure for this lotThe range repeated as the result
BasisAs-is, dried or anhydrousBasis stated only in a footnote
ConclusionPass or fail against the named limit“Complies” with no limit named

This page does not reproduce a batch result, because the figures move from lot to lot. The lot certificate carries them, and its lot code should match the pouch or drum and the retained sample.

What drifts from lot to lot

Assay and loss on drying move with crystallisation, drying and packing. A hot dryer can lower the water figure while creating colour or a harder crystal; a pack that takes up water after filling raises loss on drying while the dried-basis assay still passes. pH moves with residual acid or ammonia, and with hydrolysis in a wet pack. Particle size moves with milling and sieving, so the mesh belongs in the specification.

Specific rotation should stay near the middle of the +6.3° to +7.3° window if the material is the L form. A drift toward zero is a warning: it can mean racemisation, a different substance or a measurement made under different conditions. The rotation is a small number, so the solvent, concentration, temperature and cell length have to be controlled.

A trend across three lots says more than one result near an edge. Assay drifting low with loss on drying climbing points at water uptake in storage; pH drifting away from the window with colour darkening points at heat or hydrolysis; a sudden change in particle size points at a different mill setting or a different supplier.

When to bring in a referee

An independent laboratory is worth commissioning for a new source, a first shipment into a regulated market, a disputed result, or a label that depends on a form claim. The useful panel is targeted rather than a full repeat: chiral HPLC for D-glutamine, an independent HPLC assay against a certified standard, Karl Fischer for water, ICP-MS for the metal panel, and LC-MS for glutamic acid or the dipeptide if substitution is suspected.

Ask the laboratory to report its limit of quantification for each screen. “Not detected” without a limit describes the method's sensitivity, not the sample. Ask for the chromatogram and rotation conditions, and keep the sample under chain of custody: test the retained material, from the same lot code.

Six lines for a supplier comparison

Six lines make two quotations comparable. First, the form and the mesh, including whether the powder is the standard 40 mesh, milled to 80 mesh or granulated. Second, the assay method and its basis. Third, the specific rotation and the conditions under which it was measured. Fourth, the water method and the pH. Fifth, the contaminant and microbiological panel, with methods and limits. Sixth, the pack and the lot traceability from certificate to drum to retained sample.

Two quotations that agree on the assay but differ on the other five are not describing the same material. The catalog specification sits on the L-glutamine product page; the forms are compared on the grade page; the identity tests are set out on the identity page; and the release workflow is on the quality page. The chromatographic method is described in the HPLC note, the water test in the loss-on-drying entry, and assay is defined in the glossary.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation