What the COA for L-citrulline actually contains
The certificate for an L-citrulline lot reports appearance, identification by IR and the ninhydrin reaction, assay by titration on the dried basis, specific rotation, loss on drying, residue on ignition, the pH of a 5% solution, particle size, the heavy-metal panel and microbiology. Each row should carry the test, the method, the release limit and that lot's result. Every figure quoted on this page is the catalog specification; the batch certificate is the document that speaks for one drum.
Three lines decide the lot: the titration for how much, the rotation for which form, and the loss on drying for what the percentage is measured against.
The certificate as a test report
A certificate is auditable when each line states the test, the method, the release limit and the result the laboratory obtained. Four columns, not two: a titration and an HPLC assay of the same powder can differ by a percentage point while both are correct, and the reader cannot compare two suppliers without knowing which was used.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White crystalline powder |
| Identification | IR and ninhydrin reaction | Conforms |
| Assay, dried basis | Titration | 98.5–101.5% |
| Specific rotation | Polarimetry, dried basis | +21.5° to +23.5° |
| Loss on drying | Gravimetric | ≤0.5% |
| Residue on ignition | Gravimetric | ≤0.1% |
| pH, 5% solution | Potentiometry | 5.0–7.0 |
| Parameter | Method | Release limit |
|---|---|---|
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
Two rows carry conditions that belong beside the number. The rotation needs its solvent, concentration, path length and temperature on the line; water and 6 M hydrochloric acid do not give the same reading. The pH is defined at 5% in water, so a figure taken on a 1% solution is a different test wearing the same name.
Titration, rotation and the dried basis
The release assay is a titration. It measures the acid–base character of the dissolved amino acid against a standardised titrant, with a potentiometric or indicator end point. That makes it a quantity test: it counts titratable material and does not separate citrulline from another amino acid that titrates nearby. The certificate should name the titrant, the solvent and the end-point method, because those choices define what the percentage means.
HPLC is the separating method, and here it is the second line of evidence rather than the release assay. Citrulline has no strong chromophore, so the method either reads the amide bond at low ultraviolet wavelength or derivatises the amino group before detection; each route has its own interference profile. The report should name the column, the wavelength and the standard. The technique is described in the HPLC method note.
The dried basis decides what the percentage is a percentage of. Water is not citrulline, so the result is corrected for loss on drying: take an as-is result of 98.2% with 0.4% water, and the dried-basis figure is 98.2 ÷ 0.996 = 98.6%. Both figures are true; only one of them is comparable with a certificate that states its basis, and the correction cannot be checked unless the water figure is on the same page.
Residue on ignition counts what remains after the organic material burns away, which catches inorganic carry-over from neutralisation and ion exchange. The pH of the 5% solution is the quickest check on those same steps: citrulline is a zwitterion and its solution sits near neutral, so a reading at the edge of 5.0–7.0 usually means residual acid or base rather than a different molecule.
Release limit versus batch result
The release limit is the gate; the batch result is what the laboratory measured. They belong in separate columns, with the method beside them. A result column filled with the specification range is not a result; it is a copy of the gate, and it says nothing about the drum in front of the buyer.
Identification is reported as conforms and microbiology as a count or an absence, and those are legitimate results. Assay, rotation, loss on drying, residue and pH are numbers and should appear as the figure obtained. The distinction matters at the edge: a lot at 98.4% assay is outside the window, and a lot at +21.4° rotation is outside as well, a failure that points at the configuration rather than at the drying step.
What moves between batches
Assay and rotation move with the route and the crystallisation. Fermentation and synthetic routes built on arginine both leave traces of related amino acids, and purification decides how much; the rotation responds to optically active impurities, so it can move while the titration still reads in range. Water moves with the drying step and the filling room, and a lot dried to 0.2% can approach the 0.5% limit before it is packed.
pH moves with ion-exchange elution and neutralisation, particle size with the mill and the sieve, colour with drying temperature and trace iron. One result near an edge means little; a trend across six lots, with the rotation falling and the water climbing, says that the process or the packing room has changed.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a form claim the certificate does not prove, or a disputed result. The useful panel is short: specific rotation with the conditions stated, an HPLC assay against an external standard, a chiral separation if the configuration is in question, and ICP-MS for the metals. One sample, one report.
Ask the laboratory to state its limit of detection for any impurity screen, including the D-enantiomer; a “not detected” line without a limit is evidence about the method, not about the sample. If a result is contested, give the referee the retained sample, the certificate and the specification, and ask for the tests that separate the possible causes rather than a repeat of the same panel.
What to compare between suppliers
Put six lines side by side: declared form, assay with its method and basis, rotation with its conditions, loss on drying, pH, and particle size with the mesh. Two quotations that agree on assay and diverge on the other five are not describing the same powder, even when both are accurate.
Then check traceability. The lot code should be identical on the certificate, the drum label and the retained sample, and the certificate should say who manufactured the lot and by which route. A correct certificate can still belong to a drum that is not on the loading dock.
The catalog specification sits on the L-citrulline product page. The form comparison is on the grade page, the tests that separate the L form from a blend are on the identity page, and the release workflow is described on the quality page. The moisture limit is defined in the loss on drying note.