What the COA for glycine actually contains
A glycine certificate reports identity by IR, assay by titration on the dried basis, loss on drying, residue on ignition, chloride, the heavy-metal panel, microbiology and particle size. Each line needs its method and its release limit; the catalog range is not a batch result. The lot code on the certificate has to match the drum and the retained sample, or the document describes a different lot.
A glycine assay is only meaningful with its method, its drying basis and the chloride figure beside it.
The certificate, line by line
For each parameter the reader needs the test, the method and the release limit. The tables restate the catalog specification; the batch COA carries the result for a particular lot.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White crystalline powder |
| Identification | IR spectroscopy | Spectrum conforms to reference |
| Assay (dried basis) | Titration | 98.5–101.5% |
| Loss on drying | Gravimetric | ≤0.2% |
| Residue on ignition | Gravimetric, ignition | ≤0.1% |
| Chloride | Titration or ion chromatography | ≤0.1% |
| Parameter | Method | Release limit |
|---|---|---|
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
Chloride marks a salt load or an acid-wash residue, and it is one place where a technical-grade material can show its provenance. Residue on ignition measures the inorganic mass left after burning, catching salts that titration of the amino group will not see.
Titration, HPLC and the dried basis
Glycine is amphoteric: it has a carboxyl group and an amino group, and its 5% solution sits close to neutral. The release assay is an acid–base titration, run in a non-aqueous system so the weak amino group gives a sharp end point; the result is calculated after correcting for loss on drying. That is what “98.5–101.5% on the dried basis” means. A result above 100% is not extra purity; it is the normal uncertainty of a titration around the equivalence point.
Titration measures acid–base equivalents, not a separation. Another amino acid with a similar equivalent weight can consume titrant, and a salt that does not react can still dilute the sample. HPLC is the second view: it separates glycine from other amino acids and from glycine derivatives. Glycine has no strong ultraviolet chromophore, so the method usually needs derivatisation or a detector such as refractive index, evaporative light scattering or low-wavelength UV. The certificate should name the column, the detector and the sample preparation, not only the percentage.
The basis is part of the result. Dried basis means the assay is corrected for the water measured by loss on drying; as-is basis includes that water. At the catalog limit of ≤0.2% the correction is small, but it is not zero, and a dried-basis result cannot be compared with an as-is limit. The certificate should print the LOD and the basis beside the assay.
The limit column and the result column
The release limit is the acceptance boundary. The batch result is what the laboratory measured on that lot. Both belong on the certificate, in separate columns, with the method beside them. A result column filled with the specification range is not a result; it is a copy of the gate.
| Parameter | Release limit | Result entry |
|---|---|---|
| Assay, dried basis | 98.5–101.5% | The lot's titration figure, with the LOD used |
| Loss on drying | ≤0.2% | The lot's gravimetric figure |
| Chloride | ≤0.1% | The lot's figure and the method |
A certificate that reports only “conforms” asks the buyer to trust the conclusion without the evidence. The heavy-metal panel needs the same: four numbers, their limits and the method. If a result is below the reporting limit, the limit of quantification should be printed beside it.
What moves from lot to lot
Assay moves with the crystallisation and drying step, but the catalog window is narrow and a well-controlled lot sits near the middle. Loss on drying is more variable because it depends on the drying end point and on the pack: a lot that is on specification at release can pick up moisture in an open drum. Chloride and residue on ignition move with the process water, the acid step and the crystallisation; a trend upward is more informative than a single result near the limit.
Particle size and colour are the physical lines; a mill or sieve change is visible before the assay moves. Colour is less quantitative: a cream or tan tint can point to a hot drying step or a trace of iron, and in a blend it can be the first sign of a Maillard reaction with a reducing sugar. Request the batch record rather than rejecting on colour alone.
When an outside laboratory helps
Order an independent test for a new source, a first shipment into a regulated market, a grade claim the certificate does not prove, or a disputed result. The useful panel is not a full repeat: IR for identity, HPLC for the amino-acid profile, chloride and residue on ignition for the salt load, and ICP-MS for the heavy-metal panel, all on one submitted sample.
Ask the laboratory to report its detection and quantification limits. A “not detected” line without a limit says something about the method, not about the sample. The same principle applies to the assay: the report should name the titration system or the HPLC column and detector, and state the basis. When a result is contested, give the referee the retained sample, the certificate and the specification under a documented chain of custody.
Six lines to compare between suppliers
Put six lines side by side: assay result and method; basis and LOD; chloride; residue on ignition; heavy metals; microbiology. Two quotations that match on the assay but diverge on the other five are not describing the same powder. Add particle size and the declared grade if the material is going into a capsule or a stick pack.
The second layer is traceability. The lot code should be identical on the certificate, the drum and the retained sample; the certificate should name the manufacturer, the grade and the pack. A correct certificate can still belong to a drum other than the one on the loading dock. The catalog specification sits on the glycine product page; the tests that separate grades are on the grade page; the identity sequence is on the identity page; the release workflow is on the quality page. The IR identity test is described in the FTIR method note, and the assay definition is in the assay glossary entry.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.