02 Grade comparison

Food-grade, technical-grade or granulated: choosing a glycine grade

Technical document 02 · Reviewed 2026-11-18 · Glycine

On this page
  1. Why the grade is a specification question
  2. Food, technical and granulated side by side
  3. Particle size, granulation and flow
  4. What the grade changes in the dosage form
  5. What to write when you switch grade

Glycine is sold as food grade, technical grade, crystalline 40 mesh, milled 80 mesh and granulated. The grade changes the document set, the chloride and residue limits, the particle size and the flow, not the molecule. Choose the grade by the dosage form, the market and the specification you can defend, not by the assay alone.

In one line

Food grade and technical grade can share an assay range and still differ in the lines a supplement file depends on: chloride, residue on ignition, heavy metals, microbiology and traceability.

Why the grade is a specification question

Food grade and technical grade are commercial descriptions, not one harmonised legal status. A food-grade lot is made and tested against food law and comes with the documents a food or supplement buyer needs: a specification, a batch certificate with methods, contaminant and microbiology results, and statements on allergens, GMO status and irradiation. A technical-grade lot is intended for industrial use; its certificate may cover the assay and the physical form and stop there. The word “grade” on a quotation is therefore a claim about a file, not a purity number.

Both grades can be the same molecule, and a technical plant can run a tight assay. The difference that matters at audit is whether the impurity panel, the microbiology and the traceability were generated for food use and are available for the lot in the drum.

Food, technical and granulated side by side

What changes between glycine grades
LineFood gradeTechnical gradeGranulated food grade
Assay, dried basis98.5–101.5% by titrationMay be similar; confirm the basis98.5–101.5% by titration
Chloride≤0.1%Check; may be wider or not reported≤0.1%
Residue on ignition≤0.1%Check the figure and the method≤0.1%
Heavy metalsPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kgPanel may not be reportedSame as food grade
MicrobiologyAPC ≤1,000; yeast and mould ≤100; E. coli and Salmonella absentPanel may not be reportedSame as food grade
Particle size≥95% through 40 meshVariable; check the sieveGranulated to the agreed distribution
DocumentationFood-grade COA and statementsIndustrial COAFood-grade COA plus granulation record

Read the table down, not across. The assay row is the one that looks reassuring; the rows below it are the ones that decide whether the material can enter a supplement. “Not reported” is not the same as “absent”, and it is not the same as “within limit”.

Particle size, granulation and flow

The catalog form is a crystalline powder with at least 95% passing 40 mesh, which is about 425 µm. A milled 80 mesh grade, about 180 µm, is available on request, and granulation is a third option. The sieve figure is a release limit, not a description: two powders can both pass 40 mesh and behave differently in a hopper because the particle-size distribution and the shape are different.

Granulation binds fine crystals into larger particles. It reduces dust, improves flow and makes a stick pack or a tablet press easier to run. It does not change the assay, but it can change the dissolution rate and the mouthfeel, so the granulated grade needs its own particle-size and flow lines. Milling goes the other way: a finer powder dissolves faster and can be more cohesive, which is a problem in a low-dose capsule or a dry blend. The useful choice is the one the process can run repeatably.

What the grade changes in the dosage form

The assay basis changes the weighed amount. A 98.5–101.5% dried-basis specification is corrected for loss on drying; a formulator who weighs against an as-is figure without the LOD is using a different number. At the catalog limit of ≤0.2% the gap is small, but it is large enough to matter in a low-dose stick pack and it is a common source of a label reconciliation error.

Chloride and residue on ignition are the other two lines that move when the grade moves. Chloride is a marker for a salt load or an acid step; residue on ignition is the inorganic mass left after ignition. Neither measures glycine, but both dilute the active mass and both belong in the grade specification. In a capsule or tablet, the grade also sets flow, compression and content uniformity; in a powder stick or beverage, it sets dispersion and clarity. In a gummy or chew, heat and water are added to the process, so the reducing-sugar profile of the other ingredients becomes part of the grade decision.

What to write when you switch grade

A grade change is a specification change, even when the assay range stays the same. Write the grade name, the assay method and basis, chloride, residue on ignition, heavy metals, microbiology, particle size or granulation, the pack and the documents required with each lot. If the new grade is technical, do not carry the food-grade specification across without checking that every line is still tested.

  • “Glycine, food grade, CAS 56-40-6; assay 98.5–101.5% by titration on the dried basis.”
  • “Chloride ≤0.1%; residue on ignition ≤0.1%; loss on drying ≤0.2%.”
  • “Heavy metals: Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg; microbiology as specified.”
  • “Particle size: ≥95% through 40 mesh, or granulated to the agreed distribution.”
  • “Each lot: batch COA with methods, allergen, GMO and irradiation statements, pack and lot code.”

When not to switch: do not move a food or supplement product to a technical grade because the assay matches; the document set is the product. Do not move a fast-dissolving stick pack to a granulated grade without a dissolution check, and do not move a dusty blend to a finer milled grade without checking flow and content uniformity. The product hub carries the catalog form; the COA page shows the test lines; the food-versus-technical page follows the document gap; the particle-size note explains the sieve figure.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation