What the COA for vitamin K2 MK-7 actually contains
The certificate for a vitamin K2 MK-7 lot reports appearance, identification by HPLC retention time, MK-7 content, the all-trans share of MK-7, loss on drying, the carrier, the heavy-metal panel, microbiology and particle size. Each line needs a method, a release limit and the result measured on that lot. The ranges on this page are the catalog specification; the batch COA is the document that confirms a particular pack.
A total MK-7 assay says how much menaquinone-7 is present; the all-trans figure says which isomer was measured, and the certificate needs both.
The certificate as a test report
A certificate is auditable when every row answers three questions: what was measured, how, and against which limit the lot was released. For a 1% spray-dried powder the sheet has to describe both the menaquinone and the matrix it sits in, because the powder is not pure MK-7.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Pale yellow to yellow, free-flowing powder |
| Identification | HPLC retention time | Conforms to the MK-7 reference standard |
| MK-7 content | HPLC | 0.9–1.1% |
| all-trans isomer | HPLC, peak-area ratio | ≥92% of MK-7 |
| Loss on drying | Gravimetric | ≤5.0% |
| Carrier | Declaration and composition | Starch or gum arabic, named on the certificate |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Parameter | Method | Release limit |
|---|---|---|
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
What the MK-7 figure measures, and on what basis
The 0.9–1.1% figure is the concentration of menaquinone-7 in the powder as sold. It is not a purity statement about the molecule. At 1.0%, one gram of powder carries 10 mg of MK-7; the other 990 mg is carrier, residual moisture and the minor components that come with spray drying. The same MK-7 at 98% purity would read 98% only if the carrier were absent.
This is why a 1% powder and a pure grade cannot be compared by reading the percentage alone. The powder percentage answers how much powder to weigh; the pure-grade percentage answers how much of the ingredient is MK-7. Both are useful, and they answer different questions. A specification that does not state the basis invites the reader to compare a diluted figure with an undiluted one.
The all-trans figure is different again. It is a ratio inside the MK-7 peak, so the carrier does not dilute it. The carrier can change the content figure by a factor of a hundred; it does not change the isomer ratio. The certificate should say whether the ratio was calculated from peak areas at the method's detection wavelength and whether any cis peaks fell below the integration threshold. For an EU-bound lot it should also report cis isomers and other impurities against the entry's limits; the all-trans floor alone is not the entry's full specification.
Loss on drying belongs with these figures, not in a footnote. A spray-dried matrix can pick up moisture in handling, and a high LOD concentrates the MK-7 on a dry basis while leaving the as-is figure unchanged. Each result needs its basis stated.
Release limit versus batch result
The release limit is the acceptance boundary. The batch result is what the laboratory measured. Both belong on the sheet, in separate columns, with the method next to them. A result column filled with the specification range is a copy of the gate, not a result, and it hides where the lot sits inside the window.
Not every line needs a numeric window. Carrier is a declaration, not an assay: the certificate names the material and, on request, its proportion. Identification is a conformance statement against a reference standard. MK-7 content, the all-trans ratio, loss on drying, the heavy metals and the micro results are the measured lines, and each should carry a unit and a limit.
"Passes specification" is a conclusion, and the reader should be able to reach it from the numbers. Ask for the raw chromatogram when the all-trans result is close to 92%; the integration of the cis peaks is where a marginal result is decided.
What moves between batches
MK-7 content moves with the ratio of menaquinone to carrier in the spray-drying feed. The all-trans ratio moves with heat and light exposure during processing and storage: the trans double bonds in the side chain can isomerise, and the cis forms are the usual degradation products. Loss on drying moves with the drying step and with the pack. Particle size moves with milling and sieving; the 40 mesh limit is a flow and dispersion control, not an assay.
Heavy metals and microbiology move with the source and the plant hygiene, not with the dilution. A carrier can add its own contaminant load, so the certificate should cover the powder as sold, not only the MK-7 concentrate.
A trend across lots says more than one result near an edge: MK-7 drifting low, all-trans falling, or LOD climbing usually points to a process or storage change.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a disputed isomer result, or a form claim the supplier's certificate does not prove. The useful panel is a reversed-phase HPLC run with an MK-7 reference standard that resolves the cis isomers, a separate all-trans calculation from the same chromatogram, ICP-MS for the heavy-metal panel, and the micro suite.
Ask the laboratory to report its limit of detection for the cis peaks and to attach the chromatogram. A "conforms" line without a chromatogram does not show whether the method could see the cis forms at all. Identification has the same requirement: the reference standard must be run under the same conditions.
Give the referee the retained sample, the supplier's certificate and the specification. Chain of custody matters: the sample tested should be the sample retained, and the lot code on all three should match.
What to compare between suppliers
Put seven lines side by side: form and concentration; MK-7 result and method; all-trans and cis figures; carrier and its declaration; loss on drying; heavy metals and micro; particle size. Two quotations that agree on MK-7 content but differ on the isomer split, the carrier or the LOD are not describing the same powder.
The second layer is traceability. The lot code should be identical on the certificate, the pack and the retained sample. The certificate should say who manufactured the lot, whether the MK-7 was synthetic or fermentation-derived, and which carrier was used. A correct certificate can still belong to a pack other than the one on the loading dock.
The catalog specification sits on the vitamin K2 MK-7 product page. The forms are compared on the grade page; the isomer evidence is set out on the identity page; the release workflow is on the quality page. The chromatographic method is described in the HPLC method note, and the certificate terms are defined in the COA glossary entry.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation