MK-7 is sensitive to light and heat; the carrier decides the rest
MK-7 is a menaquinone with a long polyisoprene side chain. Light and heat act on the double bonds in that chain, and oxygen attacks the naphthoquinone ring: the trans bonds can isomerise to cis forms, and the ring can oxidise. In a sealed 1% spray-dried powder the carrier limits mobility and oxygen access; in an oil, a beverage or a gummy the matrix can accelerate them. Shelf life belongs to the pack, the carrier and the process, not to the molecule alone.
Light and heat isomerise MK-7; the carrier and the pack decide how much of that reaches the molecule.
The powder in the sealed pack
A spray-dried 1% powder is a dispersion of MK-7 in a starch or gum arabic matrix. The matrix lowers the mobility of the molecule and limits the oxygen that reaches it, which is why the dry powder is the most forgiving grade to store. The limits that matter are the ones already on the certificate: loss on drying at or below 5.0%, a declared carrier, and a pack that keeps light and moisture out.
The 1 kg foil pouch and the 25 kg fiber drum with a food-grade liner are the two standard packs. Both are opaque when closed, and both depend on the liner being intact. A drum left open in a warm room, or a pouch folded instead of sealed, exposes the powder to moisture and light and gives the matrix a chance to cake. The powder should be stored cool, dry and dark, and the pack should be closed between uses.
Oil, emulsion and the gummy matrix
An oil suspension removes the water but adds a new set of reactions. The carrier oil can oxidise, and its peroxides can attack MK-7; light passes through many oils and through clear softgel shells. A softgel therefore needs an opaque shell, a controlled headspace and an oil with its own oxidative stability. The MK-7 concentration and the oil should both be on the specification, because the oil is part of the stability system.
In a beverage, MK-7 has to be dispersed in water even though the molecule is fat-soluble. That means an emulsion or a fine dispersion, and the emulsion is usually the weaker part of the system: light in a clear bottle, dissolved oxygen, heat during pasteurisation and droplet coalescence can all shorten the shelf life before the MK-7 itself changes. In a gummy, the heat of cooking, the water activity and the cooling profile are the main variables; adding MK-7 late in the process reduces its heat exposure but does not remove the need for a stability run in the finished matrix.
What drives the loss
| Factor | What it does | Control |
|---|---|---|
| Light | Promotes trans-to-cis isomerisation and colour fade | Opaque or amber pack, light-protective secondary carton |
| Heat | Raises cis formation and oxidation during drying, blending or cooking | Lower process temperature, shorter residence time, cooling before packing |
| Oxygen | Oxidises the quinone ring and consumes the carrier system | Sealed pack, controlled headspace, antioxidant where declared |
| Moisture | Plasticises the matrix, causes caking and speeds the other routes | Loss on drying ≤5.0%, sealed pack, dry storage |
| Trace metals | Catalyse oxidation at low concentration | Source control, heavy-metal panel on the certificate |
The table is not a ranking. In a sealed powder, light and heat usually dominate because moisture and oxygen are already controlled. In an oil or an emulsion, oxygen and light move to the front. The same molecule can fail by a different route in each dosage form, which is why a raw-material stability result cannot be transferred to a finished product.
A stability protocol that can be audited
A useful protocol names the pack, the storage condition, the time points, the analytical method and the acceptance limits before the first sample goes into the chamber. A common design pairs a long-term condition, such as 25 °C and 60% relative humidity, with an accelerated condition, such as 40 °C and 75% relative humidity, and adds a light-exposure arm and an open-pack arm. The light arm is not optional for a product sold in a clear bottle or a clear capsule.
At each point the laboratory should report MK-7 content, the all-trans and cis figures, loss on drying, appearance and, for an oil or emulsion, the relevant physical tests. The all-trans figure is the early warning: it can fall before the total MK-7 content leaves its range, because isomerisation changes the shape of the molecule without removing it. A protocol that measures only total MK-7 can miss the first change.
The finished product should be tested in its own pack. A powder in a foil pouch and the same powder in a stick pack, a capsule or a gummy are different stability subjects, even when the MK-7 input is identical.
Formulation and process choices
The carrier is the first formulation decision. A starch matrix is less hygroscopic and gives a denser powder; a gum arabic matrix disperses more readily in water. Neither is a light barrier, so the pack still has to do that job. An antioxidant can be part of the carrier system, but it has to be declared and it does not replace an opaque pack; a light-exposed sample with an antioxidant will still isomerise.
Process exposure is cumulative. Spray-drying, blending, tableting and gummy cooking each add heat, and the total is what the molecule sees. Opaque capsule shells, an opaque film coating on a tablet and a secondary carton are simple barriers that are easy to specify and easy to audit. Clear capsules and clear bottles are the opposite: they look clean on the shelf and give light free access to the molecule.
Assigning a shelf life
Shelf life is assigned per pack, per formulation and per market, and it is supported by the stability data for that combination. The raw material's retest date does not establish the finished product's shelf life, and a batch COA does not establish either. The storage statement on the label should match a condition that was actually tested; a label that says cool and dry needs data at that condition, not only an accelerated run at 40 °C.
Once a 1 kg pouch is opened, the remaining powder sees a different environment. Split the pack into smaller units for a long production campaign, reseal it properly, and keep it away from light. The retained sample should come from the same lot and be stored under the same condition as the batch it represents.
The catalog specification is on the vitamin K2 MK-7 product page. The grade choice is on the grade page; the certificate lines are on the COA page; the packaging and ordering unit are on the MOQ page. The analytical method is described in the HPLC method note, and the release workflow is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation