What the COA for vitamin K2 MK-7 oil actually contains
A 1% MK-7 oil certificate has to answer four questions at once: how much menaquinone-7 the oil contains, which geometry that MK-7 has, whether the carrier is still sound, and what the other 99% of the product is. The catalog release lines cover the first and part of the third; the isomer figures and the carrier name are the lines a buyer has to ask for by name.
The assay on a 1% MK-7 oil is an as-is figure, and it means little without the all-trans ratio and the peroxide value beside it.
Reading the lot certificate
A certificate is only as useful as its least auditable line. Each row needs the parameter, the method and the limit the lot was released against; a bare “conforms” is a conclusion with the working removed. On this product the working includes a chromatogram, a titration for the peroxide value and a named carrier.
The assay is the line that travels furthest in a quotation. Read it as the MK-7 content of the oil in the bottle, not as the purity of the concentrate used in the blend. At 1.05%, one gram of oil carries 10.5 mg of MK-7; the remaining mass is the carrier and any antioxidant the specification declares.
| Test | Technique | Acceptance limit |
|---|---|---|
| Appearance | Visual | Yellow to amber, clear oil |
| Identity | HPLC retention time plus UV spectrum | Matches the reference standard |
| Assay (as-is, on the oil) | HPLC with UV detection | 1.0–1.1% MK-7 |
| Peroxide value | Iodometric titration | ≤10.0 meq O₂/kg |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate counts, yeast and mould, pathogen absence | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
Two things are absent from the catalog table: the all-trans and cis figures and the carrier oil. Neither is a release limit here, but both decide whether the lot is the product that was ordered. An assay without them describes a concentration, not a material.
The as-is basis, the dose and the isomer line
The figure is as-is on the oil. No anhydrous correction applies, because the lipid is the product and this catalog sets no loss-on-drying limit for it. The conversion is simple: 1.0% = 10 mg/g, 1.1% = 11 mg/g, so a 100 µg dose is 10 mg of oil at the low end and 9.1 mg at the high end.
The powder's certificate works differently: MK-7 on a solid matrix, a loss-on-drying line, a particle-size line. The oil's matrix is a liquid, and its own quality gate is the peroxide value. A certificate issued for the concentrate before blending is a certificate for a different material.
Isomerism is the second half of the assay. MK-7 is an all-trans molecule, and light or heat can rotate part of the chain into cis forms. The EU synthetic-route specification asks for at least 92% all-trans and no more than 6.0% cis. This catalog's release table does not print an all-trans limit, so the lot certificate should carry both figures and the purchase specification should state the limit the buyer needs. A 1.05% total can conceal a cis fraction above that limit.
Peroxide value measures the first products of lipid oxidation, in milliequivalents of oxygen per kilogram. A lot at 9.5 is inside the 10.0 limit but has less room left than a lot at 2.0; read the number as a remaining-life indicator, not only as a pass mark.
Release limit versus batch result
Release limit and batch result answer different questions. The limit is the gate the lot had to pass; the result is the measurement on that lot. They belong in separate columns, with the method named beside each.
| Line | Gate | Measured value |
|---|---|---|
| Assay | 1.0–1.1% as-is | The measured percentage and the basis used |
| Peroxide value | ≤10.0 meq O₂/kg | The measured value and the titration used |
| All-trans / cis | Agreed in the specification | Two measured shares of MK-7, not one total |
| Heavy metals | Per element | A number per element in mg/kg |
| Microbiology | Counts and absence | The count and the absence result for the lot |
A pass statement should be reconstructable from the figures. Heavy metals need a value per element, not a sum; microbiology needs a count and an absence statement; the isomer line needs the all-trans and cis figures, not an adjective.
How lots differ
An oil is a blend, so the assay follows the weigh-up: concentrate in, carrier in, and the percentage that results. Peroxide value follows the carrier lot, the antioxidant, the heat history and the days since filling. The all-trans share follows light and heat. Colour follows all of these and is the least specific of the signals.
Look for direction across lots rather than a single result at an edge: peroxide rising, all-trans falling, assay drifting. Match the lot code on the certificate to the bottle, the carton and the retained sample before drawing a conclusion about a batch.
Bringing in a referee laboratory
An outside test is worth ordering when the source is new, the market is regulated, the peroxide result is disputed, the isomer profile is claimed but not shown, or the carrier is unclear. A useful panel is not a copy of the certificate: HPLC with UV spectrum for identity and assay, a dedicated isomer separation, peroxide value by titration, ICP-MS for metals, plate counts and absence tests, and a fatty-acid profile when the carrier oil itself is in question.
Name the detection limit for every screen. A “not detected” result with no limit tells you about the method, not the sample. Keep the chain of custody tight: the tested sample should be the retained one, the report should name the lot, and a dispute should go to a referee with the retained sample, the certificate and the agreed specification in hand.
Comparing two offers
Six lines make a useful comparison: the form and carrier; the assay and its basis; the all-trans and cis figures; the peroxide value; the contaminant and micro panel; the pack and lot code. Two offers can match on assay and still describe different oils if the carrier or the isomer profile differs.
The catalog ranges are on the vitamin K2 MK-7 oil product page. The tests that separate MK-7 from MK-4 and from the cis isomers are on the identity page; the powder alternative is on the MK-7 powder product page; the HPLC method is described in the methods index; the release procedure is described on the quality page.