06 Identity & adulteration

How we prove a 1% MK-7 oil is menaquinone-7

Technical document 06 · Reviewed 2026-11-20 · Vitamin K2 MK-7 Oil

On this page
  1. Five checks that have to agree
  2. The all-trans ratio: proving the geometry
  3. Why XRD does not identify an oil
  4. Where substitutions show up
  5. The identity clauses in the specification
  6. Five questions to put to the supplier

Identity for a 1% MK-7 oil is not one test. It is the agreement of four measurements: the chromatogram identifies the menaquinone, the isomer separation fixes the geometry, the assay and carrier declaration account for the dilution, and the peroxide value says whether the oil is sound. Colour tells you almost nothing.

In one line

The total MK-7 figure can pass while the geometry fails; an oil's identity file is the chromatogram, the all-trans ratio and the carrier, not the colour.

Five checks that have to agree

Naming the material on a certificate is the easy part; showing that the lot matches the name takes independent measurements. The table separates the questions so each can be answered on its own evidence.

Five layers of vitamin K2 MK-7 oil identity
CheckWhat it answersEvidenceWhat it leaves open
DocumentIs the form and carrier declared?Name, CAS number, formula, carrierThe paper trail only
HPLC and UVIs the quinone MK-7?Retention time plus UV spectrumThe geometry of the chain
Isomer separationIs it all-trans MK-7?All-trans and cis by HPLCThe total potency
Mass balanceDoes the 1% add up?Assay plus declared carrierThe state of the carrier
Oil qualityIs the carrier sound?Peroxide value, appearance, odourThe identity of the MK-7

The all-trans ratio: proving the geometry

The all-trans requirement is a geometry requirement. MK-7's side chain has seven isoprene units, and the all-trans form is the natural configuration; light and heat can convert part of it to cis. The EU synthetic-route specification sets a floor of 92% all-trans and a ceiling of 6.0% cis, and that is the reference for the MK-7 in the oil.

An assay that reports total MK-7 cannot enforce either limit. The number is a sum over the geometries, so a lot can pass on total and fail on all-trans. Ask for two figures and the method that produced them: the column and mobile phase have to resolve the isomers, not merely elute one peak.

Why XRD does not identify an oil

X-ray diffraction reads crystal lattice spacing, which is why it is useful for a solid. An oil has no lattice to read. A diffraction pattern from an oil is broad and uninformative, and an “XRD conforms” statement on an oil certificate has no reference phase behind it. The test belongs to a crystalline material, such as isolated MK-7 or a crystalline carrier or adulterant in a powder.

For the oil, the structural evidence is the UV spectrum, the retention time and the isomer separation. A supplier who offers XRD for a liquid is probably reusing a powder certificate; ask which phase was measured and which reference was used. A genuine oil can still fail the audit on that point.

Where substitutions show up

Common MK-7 oil substitutions and the signals
Adulterant or faultWhat it doesSignalTest
MK-4 in place of MK-7A different menaquinone under the same vitamin K2 nameRetention time and molecular mass differHPLC/UV, mass spectrometry
Vitamin K1 additionRaises total vitamin K without adding MK-7Extra peak; source mismatchHPLC separation
Low all-trans oilTotal MK-7 passes; geometry failsCis fraction above the limitIsomer separation
Excess carrierAssay under 1.0%; carrier above declarationMass balance failsAssay plus carrier declaration
Carrier substitutionAllergen and stability profile changeFatty-acid profile differsGC-FID fatty-acid profile
Oxidised carrierOff-odour and MK-7 lossPeroxide value highPeroxide value, sensory

Appearance is the weakest evidence. The oil is allowed to run from yellow to amber, and a darker lot can be an older carrier or a different carrier without any change in the menaquinone. The measurements that separate a genuine lot from a substitution are the retention time, the UV spectrum, the isomer ratio and the mass balance. A certificate that shows appearance and assay but no identity work has tested the least specific properties.

The identity clauses in the specification

  • “Menaquinone-7 1% oil, CAS 2124-57-4, C46H64O2; carrier oil named.”
  • “MK-7 1.0–1.1% by HPLC, as-is on the oil; identification by retention and UV spectrum.”
  • “All-trans and cis reported separately; all-trans at least 92% of MK-7 unless another limit is agreed.”
  • “Peroxide value ≤10.0 meq O₂/kg; antioxidant declared if present.”
  • “No MK-4, vitamin K1 or other menaquinone above the stated limit.”
  • “Source route and destination market confirmed before the order.”

Five questions to put to the supplier

  1. Which menaquinone is in this lot, and what CAS number is declared?
  2. Will you send the chromatogram and UV spectrum, not just the assay figure?
  3. What are the all-trans and cis percentages, and which method separated them?
  4. Which carrier oil and antioxidant are present, at what levels?
  5. What is the peroxide value, and will you re-test the retained sample jointly if it is challenged?

Those five answers, taken together, are the identity file. A single assay figure is not. The product hub lists the catalog ranges; the COA page explains how each figure is reported; the grades page compares the forms; the MK-7 powder page shows the solid alternative; the methods index explains the separation.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation