How we prove a 1% MK-7 oil is menaquinone-7
Identity for a 1% MK-7 oil is not one test. It is the agreement of four measurements: the chromatogram identifies the menaquinone, the isomer separation fixes the geometry, the assay and carrier declaration account for the dilution, and the peroxide value says whether the oil is sound. Colour tells you almost nothing.
The total MK-7 figure can pass while the geometry fails; an oil's identity file is the chromatogram, the all-trans ratio and the carrier, not the colour.
Five checks that have to agree
Naming the material on a certificate is the easy part; showing that the lot matches the name takes independent measurements. The table separates the questions so each can be answered on its own evidence.
| Check | What it answers | Evidence | What it leaves open |
|---|---|---|---|
| Document | Is the form and carrier declared? | Name, CAS number, formula, carrier | The paper trail only |
| HPLC and UV | Is the quinone MK-7? | Retention time plus UV spectrum | The geometry of the chain |
| Isomer separation | Is it all-trans MK-7? | All-trans and cis by HPLC | The total potency |
| Mass balance | Does the 1% add up? | Assay plus declared carrier | The state of the carrier |
| Oil quality | Is the carrier sound? | Peroxide value, appearance, odour | The identity of the MK-7 |
The all-trans ratio: proving the geometry
The all-trans requirement is a geometry requirement. MK-7's side chain has seven isoprene units, and the all-trans form is the natural configuration; light and heat can convert part of it to cis. The EU synthetic-route specification sets a floor of 92% all-trans and a ceiling of 6.0% cis, and that is the reference for the MK-7 in the oil.
An assay that reports total MK-7 cannot enforce either limit. The number is a sum over the geometries, so a lot can pass on total and fail on all-trans. Ask for two figures and the method that produced them: the column and mobile phase have to resolve the isomers, not merely elute one peak.
Why XRD does not identify an oil
X-ray diffraction reads crystal lattice spacing, which is why it is useful for a solid. An oil has no lattice to read. A diffraction pattern from an oil is broad and uninformative, and an “XRD conforms” statement on an oil certificate has no reference phase behind it. The test belongs to a crystalline material, such as isolated MK-7 or a crystalline carrier or adulterant in a powder.
For the oil, the structural evidence is the UV spectrum, the retention time and the isomer separation. A supplier who offers XRD for a liquid is probably reusing a powder certificate; ask which phase was measured and which reference was used. A genuine oil can still fail the audit on that point.
Where substitutions show up
| Adulterant or fault | What it does | Signal | Test |
|---|---|---|---|
| MK-4 in place of MK-7 | A different menaquinone under the same vitamin K2 name | Retention time and molecular mass differ | HPLC/UV, mass spectrometry |
| Vitamin K1 addition | Raises total vitamin K without adding MK-7 | Extra peak; source mismatch | HPLC separation |
| Low all-trans oil | Total MK-7 passes; geometry fails | Cis fraction above the limit | Isomer separation |
| Excess carrier | Assay under 1.0%; carrier above declaration | Mass balance fails | Assay plus carrier declaration |
| Carrier substitution | Allergen and stability profile change | Fatty-acid profile differs | GC-FID fatty-acid profile |
| Oxidised carrier | Off-odour and MK-7 loss | Peroxide value high | Peroxide value, sensory |
Appearance is the weakest evidence. The oil is allowed to run from yellow to amber, and a darker lot can be an older carrier or a different carrier without any change in the menaquinone. The measurements that separate a genuine lot from a substitution are the retention time, the UV spectrum, the isomer ratio and the mass balance. A certificate that shows appearance and assay but no identity work has tested the least specific properties.
The identity clauses in the specification
- “Menaquinone-7 1% oil, CAS 2124-57-4, C46H64O2; carrier oil named.”
- “MK-7 1.0–1.1% by HPLC, as-is on the oil; identification by retention and UV spectrum.”
- “All-trans and cis reported separately; all-trans at least 92% of MK-7 unless another limit is agreed.”
- “Peroxide value ≤10.0 meq O₂/kg; antioxidant declared if present.”
- “No MK-4, vitamin K1 or other menaquinone above the stated limit.”
- “Source route and destination market confirmed before the order.”
Five questions to put to the supplier
- Which menaquinone is in this lot, and what CAS number is declared?
- Will you send the chromatogram and UV spectrum, not just the assay figure?
- What are the all-trans and cis percentages, and which method separated them?
- Which carrier oil and antioxidant are present, at what levels?
- What is the peroxide value, and will you re-test the retained sample jointly if it is challenged?
Those five answers, taken together, are the identity file. A single assay figure is not. The product hub lists the catalog ranges; the COA page explains how each figure is reported; the grades page compares the forms; the MK-7 powder page shows the solid alternative; the methods index explains the separation.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation