03 Stability

MK-7 oil is light- and heat-sensitive; the carrier and the bottle set the shelf life

Technical document 03 · Reviewed 2026-11-20 · Vitamin K2 MK-7 Oil

On this page
  1. Dry storage, the cap and the headspace
  2. The oil is already a solution
  3. What drives degradation
  4. A stability protocol for the oil
  5. The finished formula changes the answer
  6. How the shelf life is set

MK-7 oil does not fail for lack of moisture. It fails on two clocks: the carrier oxidises, which the peroxide value records, and the all-trans side chain isomerises, which the all-trans figure records. Potency is the last number to move, so a shelf life built only on assay is built on the slowest signal.

In one line

The oil protects MK-7 from moisture but not from light, heat or oxygen: the peroxide value and the all-trans ratio are the early warnings before the assay moves.

Dry storage, the cap and the headspace

An oil is not a dry powder, but the dry-storage instruction still has a job. The lipid does not pick up water the way a powder does; what it picks up is oxygen every time the bottle is opened. A dry, sealed, upright bottle in the dark is the starting condition, and the cap liner is the part that keeps it.

Glass is a light barrier, not a gas barrier. The headspace in a part-used bottle is the oxygen reservoir, and a 1 kg bottle opened daily for a month has a different history from one opened twice. Split a working stock into smaller amber bottles if the bench will be in and out of the container; keep the bulk bottle closed. Condensation on a cold neck is a small but real route for water into the oil, and humidity also attacks the label, cap and carton.

The oil is already a solution

The oil is a solution of MK-7 in a carrier, not a suspension, so there are no particles to settle. The 1.0–1.1% figure is the concentration of that solution, and diluting it into a softgel fill changes the volume and the oxygen exposure per unit of MK-7, not the chemistry of the molecule.

A fill blend adds its own risks. Other triglycerides can be more unsaturated than the MK-7 carrier, and the antioxidant has to protect the whole blend; an antioxidant chosen for one carrier is not automatically right for another. An emulsion introduces an interface and mechanical stress, and its stability has to be tested as an emulsion. Water is not a solvent for MK-7, and a water-dispersible claim requires an emulsified system with data behind it.

Light exposure is cumulative. Amber glass, an opaque softgel shell and a carton are three barriers doing the same job; each one removed shortens the oil's useful life.

What drives degradation

Stressors that shorten the oil's useful life
StressEffectPractical control
LightCis formation and photodegradationAmber glass, opaque shell, dark storage
OxygenCarrier oxidation; peroxide value climbsSealed closure, small headspace, antioxidant
HeatSpeeds both oxidation and isomerisationCool storage and a cool process
Trace metalsCatalyse oxidation at very low levelsNo iron or copper contact
Carrier unsaturationMore double bonds means faster oxidationDeclare the carrier; monitor peroxide
AntioxidantIts protection is used up over timeDeclare type and level; verify carry-through
IsomerisationAll-trans turns toward cisLimit light and heat; trend the ratio

None of these factors acts alone. A warm, bright, half-empty bottle combines heat, light and oxygen, and the peroxide value can move faster than any one factor would predict. The useful question is not whether MK-7 is stable, but how long this oil holds in this pack under this condition.

A stability protocol for the oil

Write the protocol around four fixed variables: which pack is tested, where it is stored, when it is sampled and what is measured. A typical design uses 25 °C/60% RH for long-term, 30 °C/65% RH as an intermediate condition and 40 °C/75% RH as the accelerated arm; a light-exposure arm is added because a dark chamber cannot reveal a photochemical failure.

At each point, test MK-7 by HPLC, the all-trans and cis figures, peroxide value, appearance and UV identity. Bulk oil and softgel are different samples: test the fill and the shell for the softgel, and record the opening date for a bulk bottle. Report the individual results; a pass/fail summary hides the trend.

Ask for data on the exact pack on order. Headspace-to-oil ratio differs between a 1 kg and a 5 kg bottle, and so does the opening history. Data from a different pack is a starting point, not a substitute.

The finished formula changes the answer

A softgel is a package, not just a fill. The shell controls water and oxygen transfer, can become brittle as it loses water, and can absorb material from the fill. Those are shelf-life questions for the finished unit, and bulk oil data cannot answer them.

An oil blend has its own exposure. The other oils may oxidise faster than the MK-7 carrier, and the pack may be more permeable than amber glass; the antioxidant has to protect the blend, not only the vitamin. A dry blend carrying the oil on a solid is a third matrix with its own test.

Overage belongs here. It is set from the potency curve and the label claim at the end of the shelf life, and it is a finished-formula decision. It does not compensate for a pack that admits light or a fill that oxidises. The oil-versus-powder comparison sets out how the overage differs between the two forms.

How the shelf life is set

MK-7 oil does not carry a single shelf-life number in this catalog. The carrier, the antioxidant package and the pack set it, and the number has to come with the conditions and the test panel that support it. A figure without those is a sales statement, not a shelf life.

Extending a retest period starts with re-testing the retained sample. It is not an assumption, and a bulk figure does not transfer to a repacked bottle. Pack sizes are on the product page, release tests on the COA page, pack and lead time on the MOQ page, the assay methods in the methods index, and the release workflow on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation