Reading a vitamin K1 COA: assay, refractive index and isomers
The certificate for a vitamin K1 lot reports appearance, identification by HPLC retention and UV spectrum, assay by HPLC, refractive index, related substances, the heavy-metal panel and microbiology. A usable line gives the method, the release limit and the figure measured on the lot. The ranges here are the catalog specification for phytonadione oil; the batch COA confirms a particular bottle.
An assay inside 97.0–103.0% says the oil is mostly phytonadione; the refractive index and the isomer figure say which oil it is.
How to read a row
A certificate earns its place when a row can be checked without a phone call: it names the measurement, the method and the limit the lot was released against. A row that offers only “conforms” moves the judgement back to the supplier and leaves nothing to audit. The refractive index is the simplest independent check that the bottle holds phytonadione and not a triglyceride oil with a convincing yellow colour.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Clear yellow to amber viscous oil |
| Identification | HPLC retention and UV spectrum against a phytonadione reference | Conforms to the reference |
| Assay | HPLC with UV detection | 97.0–103.0% |
| Refractive index | Refractometry, temperature stated | 1.525–1.528 |
| Related substances | HPLC, peak-area normalisation | cis-isomer and epoxide reported per lot; limit agreed on the specification |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
The identification row and the assay row answer different questions. Identification says the peak is phytonadione, by retention and by the ultraviolet spectrum of the naphthoquinone chromophore; the assay says how much is there. One peak with no spectrum has shown half of the identity.
What the percentage is a percentage of
Vitamin K1 is supplied as the substance itself, not as a diluted powder, so 97.0–103.0% by HPLC is a purity window around 100% rather than a concentration. There is no carrier to divide out and no anhydrous correction: the specification has no loss-on-drying line, and volatile matter appears as a lower assay. A “50% vitamin K1 oil” is a different product whose certificate describes a blend.
The ±3% window holds the related substances from the synthesis, the residual solvent that survives purification, and the repeatability of injecting a viscous oil. It is not a licence to read 97.1% as 100%. Weigh the oil rather than dispensing it by volume: density is not a line on this specification, and a volumetric fill carries an error that is large against a three-point window. An opened bottle is also a different sample from a fresh one, because the surface has seen air and light.
Release limit and batch result
A limit defines what will be accepted; a result records what was found. The two deserve separate columns, with the method alongside, because a column that repeats the limit says nothing about the lot and conceals where inside the window it fell.
| Parameter | Release limit | Result column |
|---|---|---|
| Assay | 97.0–103.0% by HPLC | A measured percentage, on the oil as received, with the method |
| Refractive index | 1.525–1.528 | A measured value with the temperature of the measurement |
| Related substances | cis-isomer and epoxide, limit agreed on the specification | A peak list with retention and area percentage |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
Refractive index is the line most often reported as its own limit instead of as a measurement, and it is the one where temperature matters: the value moves with the prism, so a figure without a temperature cannot be compared with the next lot. When related substances sit near their limit, ask for the chromatogram; the integration of the cis peak is where a marginal result is decided. Microbiology for a fat-soluble oil still needs a count and an absence statement.
What moves between batches
Phytonadione is made by condensing menadione with isophytol or a phytyl halide and then purifying the product. The condensation does not fix the geometry of the double bond in the phytyl chain, so the crude carries both trans and cis, and the purification decides how much cis survives. A shift in the isomer figure between lots is a process signal, not a laboratory error.
Colour is the second variable: clear yellow to amber is a wide window. A lot at the amber end after a long hold is not automatically out of specification, but a step change across lots can point at light or heat exposure before sealing. Assay and refractive index move together when residual solvent is present, and both move when the oil has taken up water, which shows as haze rather than as a lower assay. Heavy metals follow the menadione source and the equipment. One certificate proves little about a trend; three lots in a row are what turn a result into a signal.
When to order an outside test
An outside laboratory earns its fee for a new source, a first shipment into a regulated market, a disputed refractive index, or a form claim the certificate does not establish. The useful panel is HPLC with a diode-array detector and a phytonadione reference, a separate isomer calculation from the same run, refractive index at a stated temperature, ICP-MS metals and the microbiology suite.
Add a fatty-acid profile by gas chromatography when a triglyceride diluent is suspected: pure phytonadione carries no fatty acids, so a profile is direct evidence of a vegetable oil. Add residual solvents by headspace gas chromatography and water by Karl Fischer where haze is the complaint. Each screen should come with its detection limit: “not detected” without a figure says more about the instrument than about the bottle.
The chain of custody is part of the evidence: the retained sample and the tested sample should be one and the same, the report should carry the lot code, and the bottle should be the one that arrived. For a disputed result, give the referee the retained sample and ask for tests that separate the candidate materials rather than a repeat of the same assay.
Supplier comparison, line by line
Seven lines repay a side-by-side read: form and CAS number; assay with its method; refractive index with the temperature; trans and cis figures; heavy metals and microbiology; pack size and lot code; the filling date and the manufacturer. Agreeing on assay while differing on refractive index or isomer share means the two offers are not for the same oil.
Traceability is the second layer: which synthesis and purification were used, under which atmosphere the oil was filled, and whether the lot code matches the bottle, the carton and the retained sample.
The catalog specification sits on the vitamin K1 product page. The tests that separate phytonadione from a blend are on the identity page; the forms are compared on the grades page; the separation behind the assay is explained in the analytical methods library; the release workflow is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation