How to prove a vitamin K1 1% powder is what it says
A vitamin K1 1% powder has two identities to prove. The first is the vitamin: HPLC retention and the UV spectrum against a phytonadione reference, with an assay inside 1.0–1.1%. The second is the carrier and the declared content: what the other 99% of the powder is, and whether the vitamin is evenly distributed through it. An assay alone proves neither the carrier nor the uniformity.
On a 1% powder, identity has two halves: HPLC and UV show the phytonadione, and the carrier plus the declared content show what the other 99% is.
The four identity layers
A certificate can name the right vitamin and still fail to describe the powder. Each layer below answers a different question, and each needs its own evidence. A supplier who answers only the first has described the label, not the material.
| Layer | Question | Test | What it proves |
|---|---|---|---|
| Paperwork | Does the document name the form? | Name, CAS number and declared content | That the papers agree |
| Chromatography | Is the peak phytonadione? | HPLC retention plus the UV/DAD spectrum | The molecule |
| Content | Is the declared potency real? | Assay against a phytonadione standard | The concentration on the carrier |
| Carrier | What is the matrix? | Carrier identity by FTIR or the supplier's specification | The other 99% and its label consequences |
The fourth layer is the one a 1% powder adds to the usual identity file, and it is the one most often left out. The vitamin can be genuine and the lot still misdescribed if the carrier is not what the label says.
The mass balance and the isomer ratio
The ratio that matters here is the mass balance. A 1.00% assay leaves 99.00% for carrier, moisture and related substances; a 5.0% loss on drying takes 5 points of that, and the carrier accounts for the rest. If the numbers do not close, either the assay basis is wrong or an unlisted component is present.
The trans and cis ratio belongs to the phytonadione, not to the carrier. The synthesis produces both geometries, and the purification decides how much cis survives; a cis-rich oil carries through to the powder. Ask for the isomer figures on the oil lot that was blended, because a peak-area normalisation on a 99% carrier powder is not a reliable isomer test.
The carrier ratio is a label question as well. A powder that is 99% carrier is, in effect, a carrier product with a vitamin added; the carrier's identity, its source and its statements decide the allergen and GMO lines on the finished label.
What X-ray diffraction can and cannot show
X-ray diffraction on this powder describes the carrier, not the vitamin. A crystalline carrier gives sharp reflections; an amorphous carrier gives a broad halo; the phytonadione, dispersed at 1%, is too dilute and too disordered to contribute a useful pattern. A certificate that reports “XRD conforms” for the powder has told the reader about the matrix, not about the potency.
The technique has a real use in a supplier comparison: it can show that two lots use the same carrier, or that a carrier has been changed. It is not a release test for the vitamin and it does not measure content. Ask for the reference pattern and the detection limit before accepting a match.
What adulteration looks like
| Substitution | Effect | Signal | Test |
|---|---|---|---|
| Under-potency | More carrier, less vitamin | Assay below 1.0%; mass balance short | HPLC assay against a standard |
| Menadione spike | A cheaper naphthoquinone with no phytyl chain | Extra peak; different UV fine structure | HPLC/UV, mass spectrometry |
| K2 substitution | A menaquinone with a different chain | Different retention and molecular weight | HPLC/UV, mass spectrometry |
| Dye | A yellow dye copies the colour | The colour matches but the spectrum does not | UV spectrum, HPLC |
| Segregation | Uneven vitamin across the pack | Top and bottom assays differ | Multi-position sampling |
| Carrier swap | Same vitamin, different matrix | Allergen, GMO or label mismatch | Carrier FTIR, supplier specification |
Colour is the weakest signal on a pale yellow powder; a dye or a different carrier can reproduce it. The stronger signals are the assay against a standard, the mass balance, the multi-position sample and the carrier identity. A certificate that reports appearance and assay but leaves the carrier unnamed has not tested the substitution a 1% powder is most exposed to.
How to write identity into the specification
- “Vitamin K1 (phytonadione, phylloquinone), CAS 84-80-0, C31H46O2, on a carrier.”
- “Declared content 1.0–1.1% by HPLC against a phytonadione standard; basis stated.”
- “Carrier identity, specification and food-use statement; antioxidant identity and level if used.”
- “Loss on drying ≤5.0%; particle size ≥95% through 80 mesh, or the granulated profile.”
- “Identification by HPLC retention plus the UV spectrum against a phytonadione reference.”
- “Heavy metals and microbiology as listed; no menadione or other naphthoquinone above the agreed limit.”
- “Destination market, carrier and label name confirmed before the order.”
Five questions for the supplier
- Which carrier is on this lot, and what is its specification?
- Can you provide the chromatogram and the UV spectrum, not only the assay percentage?
- Is the assay on the powder as received or on the dried basis?
- How is content uniformity verified across the pouch or the drum?
- If the lot is disputed, will you test the retained sample jointly with us?
Those five answers, taken together, are the identity file; a single assay figure is not. The product hub holds the catalog specification; the COA page places each figure on the certificate; the grades page compares the powder with the oil; the vitamin K1 page covers the parent oil; the methods library explains the separation; the quality page covers the release file.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation