06 Identity & adulteration

How we prove a vitamin D2 lot is ergocalciferol

Technical document 06 · Reviewed 2026-11-19 · Vitamin D2

On this page
  1. The four identity layers
  2. The ratio that checks the paperwork
  3. X-ray diffraction and the solid state
  4. What adulteration looks like
  5. How to write the identity into the specification
  6. Five questions for the supplier

A vitamin D2 lot is ergocalciferol when the documents, the chromatogram, the ultraviolet spectrum, the melting range and the mass balance agree. The assay alone cannot separate D2 from D3, because the two molecules have similar ultraviolet spectra and the same IU convention. The form has to be proved by retention against an ergocalciferol standard and by a solid-state check.

In one line

Identity is the agreement of four measurements: retention against an ergocalciferol standard, the ultraviolet spectrum, the melting range and the mass balance.

The four identity layers

A certificate can carry the right name and still leave the material unproven. Each layer below asks a different question, and each needs its own measurement. An answer that stops at the first layer describes paperwork, not powder.

How each identity layer is tested
LayerQuestionTestWhat it proves
DocumentIs the form named?Name, CAS 50-14-6, formula C28H44OPaperwork only
ChromatographyIs the peak ergocalciferol?HPLC retention against a D2 standard, co-injectionThe molecule, if the standard is the right one
SpectroscopyIs it a vitamin D sterol?UV spectrum near 265 nm; melting rangeThe chromophore and the solid form
Mass balanceIs it diluted or mixed?Assay, loss on drying, related substancesConsistency of the numbers

The spectroscopy row is where D2 and D3 are weakest to separate. Both absorb ultraviolet light around 265 nm, so a spectrum that matches “vitamin D” does not say which molecule produced it. Retention against the matching standard is the discriminating test; the melting range supports it.

The ratio that checks the paperwork

The IU is a ratio: 40 IU per microgram of either vitamin D form, or 40,000 IU per milligram. That fixed ratio turns an assay into an IU figure and back again. A 99.0% powder carries 990 mg of ergocalciferol per gram, which is 39,600,000 IU/g. An oil declared at 1,000,000 IU/g must contain 25 mg of ergocalciferol per gram, or 2.5%. If a supplier's IU figure does not reconcile with the assay and the dilution, one of the three numbers is wrong.

The same arithmetic catches a unit error. A certificate that reports 2,500 µg/g and a specification that asks for 100,000 IU/g are describing the same concentration, because 2,500 × 40 = 100,000. A buyer who reads the microgram figure as an IU figure rejects a compliant lot; a buyer who reads it the other way accepts a lot at one fortieth of the grade.

The second ratio is the peak-area ratio when both forms are screened. A D2 peak with a D3 shoulder is a mixed lot, even when the total “vitamin D” area is inside the assay range. The certificate should name the D2 standard and state whether a D3 screen was run and at what detection limit.

X-ray diffraction and the solid state

X-ray diffraction asks about the solid: is it crystalline, and does the pattern fit an ergocalciferol reference? It can distinguish the crystal from an amorphous dispersion or a trituration, and it can compare lots from two sources. It is not a potency assay, and it does not measure the IU. Before accepting a “match” statement, ask for the reference pattern and the detection limit.

The melting range is the simpler solid-state check and is already on the catalog: 115–118 °C. A melt that begins and ends in that window is consistent with crystalline ergocalciferol; a broad or low melt points to a mixture, a solvate or a different sterol. XRD is the stronger evidence when a lot is disputed, when a new source is qualified, or when the powder is supposed to be pure but the assay is lower than the label.

Neither test replaces the chromatogram. The solid-state methods say what the powder is; the chromatogram says how much of the named molecule is present.

What adulteration looks like

Substitutions and the signals that catch them
AdulterantWhat it doesSignalTest
CholecalciferolSame chromophore, different mass and retentionD3 peak under the D2 retention windowHPLC against a D2 standard; LC-MS at 384.64 versus 396.65
ErgosterolUnconverted precursor; different UV maximumExtra peak; spectrum shiftHPLC/UV, related substances
Lumisterol or tachysterolIrradiation by-products; lower potencyIsomer peaks; assay below the labelRelated-substance method, UV
Inert dilutionLowers the assay; removes the meltAssay low; no sharp melting rangeAssay, melting range, XRD, mass balance
Oil carrier substitutionDeclared carrier is not the carrier usedFatty-acid profile differs; peroxide value highCarrier identity, peroxide value, assay after extraction

Appearance is the least specific signal. Ergocalciferol is a white crystal, and a white diluent reproduces the look without reproducing the molecule. The stronger signals are the retention time, the melting range and the mass balance. A certificate with appearance and assay but no chromatogram has not tested the likely substitution.

How to write the identity into the specification

  • “Ergocalciferol, CAS 50-14-6, C28H44O, vitamin D2.”
  • “Assay 97.0–103.0% by HPLC on the stated basis, against an ergocalciferol reference standard.”
  • “Identification by HPLC retention and UV spectrum; melting range 115–118 °C.”
  • “Loss on drying ≤0.5%; particle size ≥95% through 40 mesh.”
  • “Cholecalciferol screened and reported, with the detection limit.”
  • “No undeclared diluent; for a blend, the carrier and the IU per gram are stated.”

A negative statement carries weight only when the method could have found the substance. Pair “no cholecalciferol added” with a D3 screen, and pair “no undeclared diluent” with the mass balance and the melting range.

Five questions for the supplier

  1. Which reference standard was used, and can you send the chromatogram?
  2. How was cholecalciferol screened, and what detection limit applied?
  3. What is the melting range for this lot, and how was it measured?
  4. What is the loss on drying, and on which basis was the assay calculated?
  5. If this lot is contested, will you re-test the retained sample jointly?

Five straight answers make an identity file; one assay percentage does not. The product page carries the catalog specification; the COA page shows where each figure sits on the certificate; the grades page compares the formats; the D2 versus D3 page covers the other molecule, and the vitamin D3 page carries its specification; the HPLC method note explains the separation; the quality page describes the release workflow.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation