01 COA & batch testing

What the COA for pyridoxine hydrochloride actually contains

Technical document 01 · Reviewed 2026-11-18 · Vitamin B6

On this page
  1. The certificate as a test report
  2. Dried basis, water and the two titrations
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A pyridoxine hydrochloride certificate reports appearance, infrared identification, assay by titration on the dried basis, loss on drying, pH, chloride, residue, particle size, heavy metals and microbiology. Each line needs the method and the release limit beside the result. The ranges here are the catalog specification; the batch certificate confirms a particular pack, and the assay alone does not prove the salt.

In one line

The assay says how much pyridoxine the lot contains; the chloride and pH figures say it is the hydrochloride, and the certificate needs all three.

The certificate as a test report

A certificate that reports one percentage and “passes” cannot be audited. The useful document is a table: parameter, method, limit, result and basis. For this material the table has a distinctive shape, because assay and chloride are two views of the same salt.

Identity, assay, water and salt checks · pyridoxine hydrochloride
ParameterMethodRelease limit
AppearanceVisualWhite or almost white crystalline powder
IdentificationInfrared spectroscopyConforms to the reference spectrum
Assay (dried basis)Non-aqueous titration99.0–101.0%
Loss on dryingGravimetric≤0.5%
pH (5% solution)Potentiometry2.4–3.0
ChlorideArgentometric titration16.9–17.6%
Residue on ignitionGravimetric≤0.1%
Particle sizeSieve analysis≥95% through 40 mesh
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The release assay and the chloride line are titrations; HPLC is the separation method used when the question is what else is in the powder. A certificate with an assay but no chromatogram answers a narrower question than a buyer may assume.

Dried basis, water and the two titrations

“Dried basis” means the assay is calculated after the loss on drying is removed, so a powder carrying 0.4% water is not penalised twice. At the top of the range a 0.5% moisture load moves the as-is figure by about half a percentage point, which is why the water result belongs beside the assay.

The water is surface moisture, not water of crystallisation. Pyridoxine hydrochloride is an anhydrous salt, so 0.5% is a handling and packing limit: it says how much water the crystal picked up on the way to the drum. A result at 0.48% has passed, but it has little room left for a humid filling room.

The assay is a non-aqueous acid–base titration. In the pharmacopoeial method the sample is dissolved in formic acid and acetic anhydride and titrated with perchloric acid; the endpoint is potentiometric or crystal violet, and the result is expressed as the hydrochloride after the drying correction. The method measures the salt as the salt; a titration run on the free base would report a different number.

The chloride line is the second titration: silver nitrate in a methanol–acetic acid medium with eosin Y, reported on the dried basis at 16.9–17.6%. The theoretical figure for C8H11NO3·HCl is 17.24%, so the window is roughly 98–102% of theory. It is a stoichiometry check, not a purity range.

The pH of the 5% solution, 2.4–3.0, is the third view of the salt. A pH above the window points to free base or an alkaline diluent; a pH below it points to excess acid. The test is quick and belongs on every lot.

Release limit versus batch result

The release limit is the boundary; the batch result is what the laboratory measured. They belong in separate columns, with the method and the basis next to them. A result column filled with the specification range is not a result, it is a copy of the gate, and it tells the buyer nothing about the drum in front of them.

Read assay and chloride together. A certificate showing 99.4% assay with 17.1% chloride is coherent; one showing 100.6% with 16.5% chloride is not, even though the assay line passes. The second result says that part of the powder is not the hydrochloride, and the certificate should explain the gap rather than average it away. Residue on ignition and loss on drying account for the non-volatile and volatile fractions, but they do not sum with the assay into a mass balance: the chloride is already inside the 99–101%, because the assay is expressed on the salt.

What moves between batches

Assay and chloride move together when crystallisation and drying are under control, because both measure the same salt. When they separate, the cause is usually upstream or downstream of the reaction: a low assay with a low chloride suggests dilution with a non-chloride solid; a high assay with a low chloride suggests free base or a different vitamin salt; a high chloride with a normal assay suggests residual hydrochloric acid or a chloride-containing diluent.

Loss on drying moves with the drying step and with the pack. Material released at 0.2% can arrive higher after a long transit in a damaged liner, and the as-is assay will follow it down even though the dried-basis figure has not moved. Particle size moves with milling and sieving: 40 mesh is the standard grade, and an 80 mesh or granulated grade is a different flow and a different dust profile. Colour is the least quantitative signal: a faint cream tint can come from trace iron or a hot drying step, while a yellow cast after storage suggests light exposure.

When to order an outside test

An independent laboratory is the right check on a new source, a first shipment into a regulated market, a disputed chloride or assay result, or a claim that the powder is a single form. The panel should target the question rather than repeat the certificate: infrared against a reference, chloride by titration or ion chromatography, HPLC for retention time and peak purity, and ICP-MS for the heavy-metal panel, all on one submitted sample.

Ask for the detection limit on any “not detected” line, and for the chromatographic conditions behind an HPLC result. Chain of custody matters as well: the sample that is tested should be the sample that was retained, and its lot code should match the certificate and the pack.

What to compare between suppliers

Put six lines side by side: form and CAS; assay result, method and basis; chloride; pH and loss on drying; particle size; and the heavy-metal and microbiological results. Two offers that agree on assay but diverge on chloride, pH or mesh are not describing the same powder, even when both are called vitamin B6.

The second layer is traceability. The lot code on the certificate should be on the pack and the retained sample, and the certificate should name the manufacturing site and the drying and milling steps. A correct certificate can belong to a different drum.

The catalog specification sits on the vitamin B6 product page. The forms are compared on the grade page, the identity tests are set out on the identity page, and the release workflow is on the quality page. The HPLC separation is described in the HPLC method note, and the term is defined in the COA entry.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation