01 COA & batch testing

What the COA for thiamine hydrochloride actually contains

Technical document 01 · Reviewed 2026-11-18 · Vitamin B1

On this page
  1. The certificate as a test report
  2. What the assay measures, and on what basis
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A thiamine hydrochloride certificate reports identity by infrared spectroscopy, assay by non-aqueous titration on the dried basis, the pH of the 2.5% solution, water by Karl Fischer, sulfated ash, the nitrate limit test, particle size, heavy metals and microbiology. Each line needs three things: the test, the method and the limit the lot was released against. The limits here describe the grade, not a drum; the batch COA is what confirms the lot you receive.

In one line

The certificate has to name the dried basis and the titration, report water and pass the nitrate test; without those four lines the assay number does not describe the salt.

The certificate as a test report

A certificate is auditable when each row can be read without the specification beside it. The identity row should name the reference standard, the assay row should name the titration and its equivalence, and the water and pH rows should name the method and the concentration. A range printed without a method is a claim, not a test report.

Identity, assay and moisture · thiamine hydrochloride
ParameterMethodRelease limit
AppearanceVisualWhite or almost white crystalline powder
IdentificationInfrared, against a thiamine hydrochloride referenceConforms
AssayNon-aqueous titration, perchloric acid, potentiometric end-point98.5–101.5% on the dried basis
pH (2.5% solution)Potentiometry2.7–3.3
WaterKarl Fischer≤5.0%
Sulfated ashGravimetric≤0.1%
NitrateLimit test, ferrous sulfate ringPasses test
Physical, contaminant and microbiological limits
ParameterMethodRelease limit
Particle sizeSieve analysis≥95% through 40 mesh
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

What the assay measures, and on what basis

The dried basis corrects the result for water, so 98.5–101.5% describes the anhydrous salt, not the powder as sold. Water is allowed up to 5.0%, and the two limits interact: a lot at 99.0% on the dried basis with 4.8% water carries about 94.2% thiamine hydrochloride as-is. The conversion is arithmetic, and the label dose has to be calculated from the as-is figure.

The titration is the pharmacopoeial release method for the pure salt. Thiamine hydrochloride is dissolved in anhydrous formic acid with acetic anhydride and titrated with 0.1 M perchloric acid to a potentiometric end-point; 1 mL of titrant is equivalent to 16.86 mg of C12H17ClN4OS·HCl. The titration is fast and precise but not a separation: it measures thiamine salt equivalents, cannot see a degradant that still titrates, and is not the right method for a blend.

HPLC with ultraviolet detection is the method that separates. It is used to confirm the assay when the material is in a premix, to resolve the impurity profile and to follow stability, because the degradation products that matter do not titrate like the parent. A certificate that says only “titration and HPLC” has not said which method produced which number. Ask for the method beside each result, and for the chromatogram when the peak purity is the question.

The salt form is a separate question from the assay. A pure mononitrate read against the hydrochloride equivalence calculates at about 103%, outside the 98.5–101.5% window, but a blend of the two salts can land inside it. The assay narrows the question; the nitrate test, the pH and the infrared spectrum answer it.

Release limit versus batch result

The release limit is the acceptance boundary; the batch result is what the laboratory measured on the lot. They belong in separate columns. A result column filled with the specification range is not a result, it is a copy of the gate. For identity, nitrate and microbiology a pass or “conforms” entry is legitimate, provided the method is named; for assay, water, pH and sulfated ash the number itself should appear.

Water is the result most often omitted and the one that changes the meaning of the lot. A certificate that reports 99.5% on the dried basis and no water figure cannot be converted to an as-is dose. Nitrate deserves the same attention: “passes” is the correct form for a limit test, but the report should name the test, and a buyer who wants a number should ask for the method and its detection limit rather than a percentage that the test does not produce.

What moves between batches

Water moves first because the hydrochloride is hygroscopic; drying time, the humidity in the packing room and the integrity of the liner all show up in the Karl Fischer result. The assay on the dried basis is comparatively tight, but its as-is value follows the water. pH moves with residual acid and with the drying step, and a drift towards the top of the 2.7–3.3 window is worth a question about the process rather than an automatic rejection.

Colour is less quantitative and often more revealing. A white to almost white powder that arrives with a yellow tint may have seen heat, light or a trace of iron; the assay can still pass. Request the batch record and a re-test rather than accepting or rejecting on appearance alone.

Particle size moves with milling and sieving. The catalog standard is at least 95% through 40 mesh, and an 80 mesh or granulated grade is a different physical article with its own flow and dust behaviour.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, a disputed result, or a lot whose salt form is uncertain. The useful panel is not a full repeat: infrared against a thiamine hydrochloride reference, HPLC assay with an impurity profile, the nitrate limit test, chloride identity, Karl Fischer water and ICP-MS for the heavy-metal panel, all on one submitted sample.

Ask the laboratory to report its detection limit for the nitrate test and the wavelength and column for the HPLC. A “not detected” line without a limit is evidence about the method's sensitivity, not about the sample. The sample tested should be the sample retained, and the lot code should follow it through the chain of custody.

What to compare between suppliers

Six lines to place side by side before two quotations are read as equal
LineWhat the certificate should show
Salt and CASThiamine hydrochloride, CAS 67-03-8; mononitrate is a different article, CAS 532-43-4
Assay and basisThe percentage, the method and “dried basis” stated together
WaterA Karl Fischer result, not only the ≤5.0% limit
Counter-ionNitrate passes, and chloride identity where the pharmacopoeia requires it
PhysicalpH, sulfated ash, particle size and the microbiological results
TraceabilityLot code matching the pouch or drum and the retained sample; manufacturer named

Two quotations that agree on the assay but differ on water, nitrate and particle size are not describing the same powder. The catalog specification sits on the vitamin B1 product page; the salt comparison is on the grade page; the tests that separate the salts are on the identity page. The separation method is described in the HPLC method note, and the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation