01 COA & batch testing

What the COA for vitamin A 500,000 IU/g actually contains

Technical document 01 · Reviewed 2026-11-19 · Vitamin A

On this page
  1. The certificate as a test report
  2. What the IU figure measures
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A vitamin A certificate has to do two jobs at once: report the IU/g result and describe the matrix that carries it. The expected lines are appearance, HPLC identification, assay in IU/g, carrier, loss on drying, particle size, heavy metals and microbiology, each with a method and limit. Everything quoted here is the catalog specification for the spray-dried acetate; a particular pouch or drum is confirmed by its batch COA. Because the IU is a converted unit, the sheet must show the conversion.

In one line

The 500,000 IU/g figure is an HPLC result expressed in a unit, so the certificate has to show the method, the basis and the carrier that make up the rest of the powder.

The certificate as a test report

Every row should stand on its own: the parameter, the method that produced the number, and the limit the lot was released against. For this product there is a fourth question: the vitamin is a small part of a spray-dried powder, and the matrix is the rest.

Identity, assay and matrix · vitamin A 500,000 IU/g powder
ParameterMethodRelease limit
AppearanceVisualLight yellow to yellow, free-flowing powder
IdentificationHPLC retention timeConforms to a retinyl acetate reference standard
Vitamin AHPLC, UV detection≥500,000 IU/g
Retinol equivalentCalculated from the assay≥150,000 µg RE/g (150 mg RE/g)
CarrierDeclarationGelatin, sucrose and starch, each named
Loss on dryingGravimetric≤5.0%
Particle sizeSieve analysis≥95% through 40 mesh
Contaminant and microbiological limits
ParameterMethodRelease limit
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The lot code, the manufacturing date, the retest or expiry date, the pack size and the specification version belong on the same sheet. A column filled with the specification range is a copy of the gate, not a measurement; “passes specification” is a conclusion the reader should be able to reach from the numbers above it.

What the IU figure measures

The IU is a unit of vitamin A activity, not a unit of mass. For retinol and its esters the convention assigns 3.33 IU to one microgram of retinol, so one IU is 0.3 µg of retinol equivalent. The laboratory measures the ester or the retinol by HPLC and the certificate converts that mass result into IU/g. The IU/g value is arithmetic on top of the chromatogram, not a separate determination.

One gram of the 500,000 IU/g powder contains 150 mg of retinol equivalent, or 15% by mass. Pure retinyl acetate is about 2.9 million IU/g, so this grade contains roughly 17% ester and about five times as much carrier, moisture and minor solids. The same arithmetic shows that an IU figure is a statement about dilution as well as about potency.

The certificate should say whether the method measures the ester directly or saponifies it to retinol. A direct method reports the acetate; saponification reports total vitamin A after hydrolysis, including free retinol. Both are legitimate, but two numbers are comparable only when the method and the basis match. With a 5.0% loss-on-drying allowance, the dried-basis result runs above the as-sold figure.

Release limit versus batch result

The specification supplies the pass mark; the batch result supplies the measurement. Keep them in separate columns and state the method once per line. The batch COA confirms the lot, while this page states the catalog limits the lot is released against.

The carrier is declared, not assayed: the certificate names gelatin, sucrose and starch and, on request, their proportions. Identification is a pass/fail comparison with a standard. The assay, moisture, mesh, metals and micro results are measured values; every one needs a unit and a limit.

The catalog sheet does not set a free-retinol or isomer limit. When oxidation is a concern, ask for the chromatogram and the stability data rather than reading the IU result as the whole picture. A peak that passes the assay can still sit beside a rising retinol or cis-isomer region.

What moves between batches

The assay follows the solids in the spray-drying feed: more vitamin premix per part carrier lifts the IU/g, while dryer losses pull it down. A carrier lot with a different moisture content shifts the as-sold figure without changing the vitamin input.

The carrier matters in its own right. Gelatin, sucrose and starch differ in flow, density, dispersion and hygroscopicity; a change in their ratio or in the gelatin grade alters the powder even when IU/g stays inside the range. Milling and sieving set the 40 mesh figure, and a worn screen shows up as a particle-size shift.

Colour is a crude signal, but it often flags what the assay does not. A deeper yellow can reflect a higher carotenoid load, heat exposure or oxidation while the assay passes; request the batch record before rejecting a lot on colour alone. A drift across several lots tells you more than a single result close to its limit.

When to order an outside test

Use an outside laboratory when the source is new, when the market is new, when a label must be defended, or when a result is disputed. The useful panel is HPLC against a retinyl acetate standard, a hydrolysis step followed by gas chromatography of the fatty acid to show acetate rather than palmitate, ICP-MS and the micro suite.

Ask the laboratory for its detection limit for retinyl palmitate and beta-carotene. Without a stated limit, “not detected” describes the method's reach, not the sample. The report should name the column, mobile phase, wavelength and basis, and state whether the sample was saponified.

When a result is contested, the referee should be a laboratory with no stake in the answer. Give it the retained sample, the certificate and the specification, and ask for the tests that separate the esters; the sample tested should be the sample retained.

What to compare between suppliers

Seven fields make two quotations comparable: the ester and the IU/g; the assay method and standard; the retinol equivalent in µg/g; the carrier and gelatin source; loss on drying; particle size; and the contaminant panels. Matching IU/g while differing on ester or basis does not make two offers equivalent.

Traceability is the second check. One lot code has to appear in three places: the certificate, the pack and the retained sample. The certificate should identify the manufacturer and the carrier; a genuine certificate still does not prove that the pack in front of you came from that lot. Request the version of the specification that governed the release.

The catalog table is on the vitamin A product page. For the ester decision, use the grade page; for identity testing, the identity page; for ordering, the MOQ page. For the separation, see the HPLC method note; for certificate vocabulary, the COA glossary entry; for release, the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation