How to prove a thiamine mononitrate lot is the nitrate salt
A lot can be called thiamine mononitrate when four checks line up: the paperwork names the form and its CAS number, HPLC retention and the infrared spectrum agree with the reference, nitrate sits near the theoretical 18.9% while chloride is below the limit of detection, and the assay with loss on drying accounts for the rest of the mass. A percentage on its own cannot separate this salt from the hydrochloride, a blend or a diluted powder.
Retention and infrared say thiamine; nitrate says this salt; chloride and moisture close the case.
Four checks, four questions
A name on a certificate is a claim, not a proof. Each check below answers a different question and needs its own evidence; a supplier who replies only to the first has shown the paperwork, not the powder.
| Check | What it rules out | Evidence |
|---|---|---|
| Paperwork | A wrong name or CAS number | Salt name, CAS 532-43-4, formula |
| Chromatography | A different vitamin or a missing peak | HPLC retention time and the peak spectrum |
| Counter-ion | The hydrochloride or a blend | Nitrate near 18.9% and chloride absent by ion chromatography |
| Mass balance | A dilution or excess water | Assay, loss on drying and related substances |
HPLC and infrared: the molecule and the solid
A usable HPLC method states its column, mobile phase, detection wavelength and standard. Identity is retention time plus a spectrum of the peak; a single peak at the right time can still be a different thiamine salt, because the cation is the same. The infrared spectrum answers the second question: the nitrate absorption and the fingerprint region compare the whole solid with a reference, so a hydrochloride lot does not match a mononitrate reference.
Ask for the chromatogram and the infrared spectrum, not only the percentage. A certificate that reports “HPLC and IR conform” without the reference or the spectrum has given a conclusion. The infrared method note explains what the comparison can and cannot show.
The counter-ion ratio: proving the nitrate salt
Thiamine mononitrate is one thiamine cation to one nitrate ion. The theoretical nitrate content is 62.00 ÷ 327.36 = 18.9% by mass, and the thiamine content is 81.1%. A nitrate result close to 18.9%, with a chloride result below the method's detection limit and an assay near 100%, is consistent with the mononitrate. A nitrate result far under 18.9%, including none detected, suggests the hydrochloride, a diluted powder or another salt; a figure above the theoretical value points to a nitrate-rich diluent or a blend.
The hydrochloride is the practical alternative, and it has the opposite pattern: two chlorides, about 21.0% chloride by mass, and no nitrate. That makes ion chromatography the cleanest discriminator between the two commercial salts, better than appearance and better than the assay. Sodium is not part of either salt, so a sodium result is a dilution signal rather than an identity test.
The pH line supports the counter-ion. A 5% solution at 6.5–7.5 fits the mononitrate; a hydrochloride solution is acidic. pH is not quantitative and moves with concentration, so it is a check, not the proof.
X-ray diffraction: the solid-state check
X-ray diffraction answers a different question: is the solid crystalline, and does its pattern match a reference? It can distinguish a crystalline salt from an amorphous carrier or a dilution, and it can compare lots from two sources. It is not a purity assay and it does not measure the counter-ion. Before accepting a “match”, ask which reference pattern was used and what the detection limit was.
For a disputed lot, diffraction plus ion chromatography plus HPLC is stronger than any one of them. Diffraction is not a routine release test for this product; a certificate that says only “XRD conforms”, with no pattern attached, has added little. The method earns its place when the question is solid form, for example when a granulated or milled grade behaves differently from the reference.
What adulteration looks like
| Adulterant | What it does | Signal | Test |
|---|---|---|---|
| Thiamine hydrochloride | Same vitamin, different counter-ion | Chloride present; nitrate absent; acid pH | Ion chromatography, pH, infrared |
| Carbohydrate diluent | Lowers the assay per gram | Assay low; strong O–H band; different LOD | Assay, infrared, loss on drying |
| Other B vitamin | Colour or assay shift | Yellow tint; extra HPLC peak | HPLC with ultraviolet detection |
| Moisture | Raises loss on drying; lowers the as-is assay | LOD above 1.0%; dried-basis assay normal | Loss on drying, assay basis |
| Degraded lot | Lower potency; off-colour powder | Related substances; grey or yellow cast | HPLC related substances, appearance |
Appearance is the weakest signal. White to off-white covers a wide range, and a grey or yellow cast can come from drying, light exposure or a contaminant. The stronger signals are the counter-ion, the infrared match and the mass balance. A certificate that reports appearance and assay but no identity has left the most likely substitution untested.
How to write identity into the specification
- “Thiamine mononitrate, CAS 532-43-4, C12H17N5O4S.”
- “Assay 98.0–101.0% by HPLC; the certificate states the basis.”
- “Identification by HPLC retention, ultraviolet spectrum and infrared spectrum against a reference.”
- “Nitrate about 18.9% by ion chromatography; chloride below the detection limit.”
- “Loss on drying ≤1.0%; pH 6.5–7.5 in 5% solution.”
- “No related substance above the stated limit; particle size ≥95% through 80 mesh.”
- “Destination market and salt form confirmed before the order.”
Five questions for the supplier
- Which salt form is this lot, and which CAS number is on the certificate?
- Can you provide the HPLC chromatogram and the infrared spectrum, not only the assay percentage?
- What are the nitrate and chloride results by ion chromatography, and what are the detection limits?
- What is the loss on drying, and on which basis was the assay calculated?
- If we disagree about a result, will you re-test the retained sample at a laboratory we both accept?
Five straight answers make an identity file; one assay figure does not. The product hub carries the catalog specification; the COA page shows where each of those figures is reported; the grades page compares the physical forms; the level-four comparison covers the label consequences; the hydrochloride identity page is the mirror test for the other salt, the hydrochloride product page is its specification, the methods library describes the tests, and the quality page covers release.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation