What the COA for thiamine mononitrate actually contains
The certificate for a thiamine mononitrate lot reports appearance, identification by HPLC and infrared, assay by HPLC, loss on drying, pH, the heavy-metal panel, microbiology and particle size. The release limits below are the catalog specification; each measured result belongs in its own column beside the method that produced it. The line that separates this salt from thiamine hydrochloride is the counter-ion rather than the percentage, so identity and moisture carry as much weight as the assay.
An assay says how much thiamine is present; only the identity and the counter-ion say that the powder is the mononitrate salt.
What the release panel reports
Each row should let a reviewer check the conclusion: the test, the method that produced the number, and the limit the lot had to meet. A row that says only “conforms” cannot be checked. The panel below is what this product is released against.
| Test | Procedure | Limit for release |
|---|---|---|
| Appearance | Visual | White to off-white powder |
| Identification | HPLC retention and infrared spectrum | Conforms to the reference |
| Assay | HPLC with ultraviolet detection | 98.0–101.0%, basis stated on the certificate |
| Loss on drying | Gravimetric | ≤1.0% |
| pH (5% solution) | Potentiometric | 6.5–7.5 |
| Heavy metals | ICP-MS | Lead ≤3, arsenic ≤2, cadmium ≤1, mercury ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | Aerobic plate count ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella not detected |
| Particle size | Sieve analysis | 95% or more passes 80 mesh |
The identity line ties the lot to the form: HPLC retention shows a thiamine peak, and the infrared spectrum compares the whole solid with a reference, including the nitrate counter-ion. A certificate that lists only a retention time has shown the vitamin, not the version of it.
Assay basis, moisture and the nitrate counter-ion
The assay has to say what it is a percentage of, and on what basis. A result of 99.0% on the dried basis with 0.8% loss on drying is 98.2% of the powder as weighed; the two figures describe the same powder, and only one of them is the amount in the scoop. The basis belongs in the assay row, not in a footnote.
The second basis question is the salt itself. Thiamine mononitrate is 81.1% thiamine by mass and 18.9% nitrate; a certificate assay is a figure for the salt, while a label often declares thiamine. A 100 mg quantity of the salt carries 81.1 mg of thiamine, and a label that declares 100 mg of thiamine needs 123 mg of the salt. Mixing the two figures is a common arithmetic error in a B1 specification.
The pH line is a supporting check with a diagnostic use. A 5% solution of the mononitrate sits at 6.5–7.5, close to neutral; a hydrochloride solution is acidic. A certificate that reports an acid pH against this specification is describing a different salt, or a lot that has been acidified. The monograph storage statement also asks for a tight, light-resistant container, and the certificate should name the pack the lot was released in.
Release limit versus batch result
One column is the gate the lot had to pass; the other is what the laboratory actually found. They stay separate, with the method beside them. If the result column repeats the range, it is a copy of the gate rather than a measurement.
| Test | Limit | What the result column shows |
|---|---|---|
| Assay | 98.0–101.0% | A measured percentage with the basis and the method |
| Loss on drying | ≤1.0% | A measured percentage and the drying condition |
| pH | 6.5–7.5 at 5% | The measured pH with concentration and temperature |
| Heavy metals | Per element | One measured value per element, in mg/kg |
| Microbiology | Count plus absence | A plate count and the absence finding for this lot |
| Identity | Conforms | Retention time, infrared match and the reference used |
“Passes specification” is the reviewer's conclusion, and the page should let the reader check it. A micro result is a count and an absence finding; a heavy-metal result is a number for each element rather than one combined figure. A combined total hides the element that matters.
What moves between batches
The synthesis and crystallisation steps move the colour and the residual moisture; drying moves the loss on drying; milling and sieving move the particle-size result. The 80 mesh line is a finishing specification, so it can change with a new mill or sieve while the chemistry is unchanged. Colour is a wide window here, white to off-white, and a shift inside it is not an identity failure; a grey or yellow cast is worth a question.
A single result near an edge says less than a trend across lots. Assay drifting low, loss on drying climbing, or a new peak in the chromatogram all point to a process change or a degradation route. The certificate's lot code should tie the pouch, the drum and the retained sample together, so any trend can be traced back to its source.
Chloride is not a specification line, but it is a useful screen. A mononitrate lot should contain no significant chloride; a result above the method's detection limit suggests hydrochloride carry-over, a shared line or a mislabelled lot. Ask for the ion-chromatography result when the form is disputed rather than reading the assay again.
When to order an outside test
Commission an outside test when a source is new, when the first consignment enters a regulated market, when the supplier's certificate does not settle a salt-form claim, or when a result is contested. The panel to request is not a duplicate of the release sheet: HPLC for assay and related substances, infrared for identity, loss on drying, ion chromatography for nitrate and chloride, ICP-MS for the metals and a plate count.
Add X-ray diffraction if the solid form is in question, and a nitrate-specific check if a nitrate salt could have been used as a diluent. Ask for the detection limit of each screen; a “not detected” line without a limit is evidence about the method, not the sample. The sample tested should be the sample retained, and the report should identify the lot.
What to compare between suppliers
Six lines make two offers comparable: salt and CAS number; assay value and basis; identity by HPLC and infrared; loss on drying; pH; and the metal and micro results. If two offers agree on the assay but not on the basis or the counter-ion, they are quoting different materials.
The catalog specification is on the thiamine mononitrate product page. The tests that separate the salt from the hydrochloride are on the identity page; the same comparison for the other salt sits on the vitamin B1 hydrochloride page; the methods are described in the analytical methods library; the release workflow is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation