01 COA & batch testing

What the COA for niacin actually contains

Technical document 01 · Reviewed 2026-11-19 · Niacin

On this page
  1. The certificate as a test report
  2. What each figure is measured against
  3. Release limit versus batch result
  4. What moves between batches
  5. When an outside test is worth it
  6. What to compare between suppliers

The certificate for a niacin lot reports appearance, identification by IR and UV, assay by titration on the dried basis, melting range, loss on drying, residue on ignition, chloride, sulfate, the heavy-metal panel, particle size and microbiology. Each line should name the test, the method and the limit the lot was released against. The values on this page are the catalog specification for nicotinic acid; the batch COA carries the result for one drum. A figure near 100% does not, by itself, separate niacin from niacinamide.

In one line

The titration counts acid groups; the melting range and the two limit tests say that the acid is nicotinic acid.

The certificate as a test report

A certificate becomes auditable when a reviewer can rebuild the release decision from the page. Each row needs the parameter, the method that produced the number, and the limit the lot was measured against. The tables below hold the catalog limits for this grade, not the outcome of a particular lot.

Identity, assay and physical tests · niacin (nicotinic acid)
ParameterMethodRelease limit
AppearanceVisualWhite to slightly yellow crystalline powder
IdentificationIR and UV against a reference spectrumConforms
Assay, dried basisAcid–base titration99.0–101.0%
Melting rangeCapillary method234–238 °C
Loss on dryingGravimetric, 105 °C≤1.0%
Residue on ignitionGravimetric≤0.1%
Particle sizeSieve analysis≥95% through 40 mesh
Limit tests, contaminants and microbiology · niacin
ParameterMethodRelease limit
ChlorideComparative limit test≤0.02%
SulfateComparative limit test≤0.02%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The set follows the monograph pattern for nicotinic acid: titration on the dried basis, melting range, and chloride and sulfate as comparative limit tests at 0.02%. A pharmacopoeial grade is agreed against the current monograph, and the certificate cites that edition.

What each figure is measured against

The assay is a direct acid–base titration of the carboxylic acid, and the arithmetic is one mole of base per mole of nicotinic acid. The result is calculated on the dried substance, which is why the loss-on-drying figure sits beside it. Take a lot at the top of the assay window that carries 0.8% water: the as-is figure lands about a point lower, both figures can be correct, and a quotation that omits the basis is comparing two different measurements. Water is the easiest diluent to add to any powder, so an as-is assay rewards a damp lot; the dried basis pushes water into its own row, where the ≤1.0% limit applies.

HPLC does a different job. The catalog names titration and HPLC as the methods for the grade; the assay figure is the titration, while the chromatographic run supports identification and the related-substance picture, looking for the amide, the positional isomer and residual nitrile from the synthetic route. The specification can set a limit for each named impurity, and that limit belongs on the certificate rather than in a separate letter.

Chloride and sulfate are limit tests, not assays. They compare the sample against a standard under fixed conditions and answer a yes-or-no question at 0.02%. They are worth keeping because they point at the process: hydrochloric or sulfuric acid used in the route, or process water that was not fully removed, shows up here first. Neither figure is a purity percentage, and neither can be added to the assay.

The melting range is an identity check. A pure crystalline lot melts inside 234–238 °C within a narrow span. A blend, a salt or a wet lot melts low, broad or in two steps, even where the titration lands inside the assay window. Literature values sit a few degrees higher; this range is the release window.

Release limit versus batch result

The release limit is the acceptance boundary; the batch result is what the laboratory measured on that drum. Both belong on the certificate, in separate columns, with the method named. A result column that repeats the specification range is not a result — it is a copy of the gate. Some rows legitimately carry “conforms” — identification and the limit tests are comparisons — but the certificate should name the reference and limit behind that word.

When a result lands at the edge, the useful next step is a repeat on the retained sample with the same method, not a re-issued certificate with different rounding. One result just under the chloride limit says less than three lots creeping upward across a year; the trend is the conversation. Units need the same care: metals in mg/kg, assay in per cent on the dried basis, particle size as the fraction passing a stated mesh.

What moves between batches

The assay window is narrow and usually well controlled; the figures tied to handling move more. Loss on drying tracks the drier and the pack. Chloride and sulfate track the acid charge and the wash. Particle size tracks the mill and the sieve; 40 mesh and 80 mesh behave differently on a capsule line.

Colour is the least quantitative signal and often the most useful. The specification allows white to slightly yellow; a deeper yellow or a brown tint can come from a hot drying step, a trace of iron or a long spell in a warm warehouse, and it can appear while the assay still passes. Ask for the batch record and the storage history before rejecting on colour alone.

When an outside test is worth it

Commission an independent test for a new source, a first regulated shipment, a disputed result, or a lot whose form is claimed but not demonstrated. The useful panel is targeted: IR against a reference, melting range, titration plus the HPLC related-substance scan, and ICP-MS for the metals panel, all on one submitted sample.

Ask the laboratory to report its detection and quantification limits. A “not detected” line without a limit describes the method, not the sample. For a dispute, the referee needs the retained sample, the supplier's certificate and the agreed specification, and the chain of custody should connect the sample tested to the lot code on the drum.

What to compare between suppliers

Six lines carry most of the comparison: the form as named, with its CAS number; the assay method and the basis it is calculated on; the melting range as a result, not a range; the chloride and sulfate results; loss on drying and particle size; and the metals and microbiology panels. Two quotations that agree on assay but diverge on the other five are not describing the same powder. Lot traceability is the second layer: the code should be identical on the certificate, the drum label and the retained sample, and the certificate should name the manufacturer.

The catalog limits sit on the niacin product page. The two vitamin B3 forms are compared on the grade page, and the tests that separate them are on the identity page. The release workflow is described on the quality page, and the chromatographic method in the HPLC method note.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation