01 COA & batch testing

What the COA for natural tocopherol actually contains

Technical document 01 · Reviewed 2026-11-20 · Natural Tocopherol

On this page
  1. Reading the certificate line by line
  2. The assay basis and the ways to express one result
  3. Release limits and the result column
  4. What varies from lot to lot
  5. When an outside laboratory is needed
  6. Comparing two quotations

A natural tocopherol certificate is read in four blocks: appearance and identity, the d-alpha-tocopherol assay, the peroxide value, and the contaminant and microbiology panels. Each line needs its method, its release limit and the measured result in separate columns, and the assay needs the isomer named beside it. The limits in the first table are catalog values; the lot certificate is what applies to the bottle in front of you.

In one line

The assay, the peroxide value and the isomer name belong on the same certificate, because a d-alpha percentage without the rotation and the oxidation state does not describe the oil.

Reading the certificate line by line

An auditable certificate gives, for every parameter, the test, the method and the limit the lot was released against. A line that reads only “conforms” offers a judgement with nothing behind it.

Two rows carry the identity: identification asks whether the material is alpha-tocopherol, and the assay asks how much of the d isomer is present. Neither answers the question the word natural raises, which is the optical form.

Identity, assay, oxidation and contaminants · natural tocopherol oil
ParameterMethodRelease limit
AppearanceVisualYellow to amber oil
IdentificationHPLC retention and UV spectrumConforms to the reference
Assay, d-alpha-tocopherolHPLC with UV detection≥90.0%
Peroxide valueIodometric titration≤10.0 meq O₂/kg
Specific rotationPolarimetry, solvent statedReported where agreed
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The peroxide value is the row buyers skip and then regret: it measures the condition of the oil rather than its composition, and it moves first when a lot has been stored warm or in a half-empty bottle.

The assay basis and the ways to express one result

The oil is weighed as received, so the assay is an as-is figure and the certificate should say so. There is no drying step to divide out, and a result carried to an anhydrous basis would describe a material that is not in the bottle.

A 90.0% result means 900 mg of d-alpha-tocopherol in a gram of oil. At 1.49 IU per milligram the same gram carries about 1,341 IU. The percentage, the milligram figure and the IU figure are three expressions of one measurement; when a specification quotes the percentage and a label quotes IU, the factor between them belongs in writing.

The assay is not an alpha-tocopherol equivalent. The α-TE conversion is a labelling convention with a form-specific factor, and it is applied to the finished product rather than to the certificate. Nor is 90.0% a statement that the other tenth is inert: the remainder is other tocopherol homologues, a carrier oil or oxidation products, and a homologue profile is how that is settled.

The same HPLC run gives the assay and the first half of the identity. The method should state the column, the mobile phase, the detection wavelength, the standard and the integration; if the natural claim is contested, ask for the chromatogram and the spectrum.

Release limits and the result column

A release limit is where a lot was accepted or rejected; the batch result is what the laboratory actually measured. Both belong on the page, with the method beside them. A column that copies the specification range has certified nothing.

What the result column should contain
ParameterRelease limitResult column
Assay, d-alpha-tocopherol≥90.0%A measured percentage, with the method and the isomer named
Peroxide value≤10.0 meq O₂/kgThe measured value and the reference method
Specific rotationAgreed at orderA measured figure with solvent and concentration
Heavy metalsPer elementA figure in mg/kg for each element, not a total
MicrobiologyCounts and absenceThe count and the absence statement for the lot

Two lines need a number rather than a conclusion. The peroxide value needs the measured figure, because a result near the 10.0 limit leaves little room for storage. The specific rotation needs its measured value with conditions: it separates the natural d form from the synthetic dl material, and “conforms” cannot be checked.

What varies from lot to lot

The feedstock is a vegetable-oil deodorizer distillate, usually from soy, sunflower or rapeseed, and the concentration step that raises the alpha fraction is where the assay is set. A different feedstock changes the homologue profile and the source record; a different concentration step changes where inside the 90% range the lot lands.

Peroxide value moves most between lots, since it depends on how old the distillate is, how much heat the concentration step applied, what headspace the holding tank had and how long the oil waited before filling. Colour follows it: yellow to amber is a wide window, and a darker, duller oil is a storage question before it is an identity failure.

Specific rotation should not move. If it does, the question is what was blended in, not what the process did. Assay drift inside the range is normal; a step change in assay with a flat rotation points to a dilution, a step change in both to a different source.

When an outside laboratory is needed

An outside laboratory earns its fee on a new source, a first shipment, a natural claim the certificate does not back, or a disputed result. The panel worth ordering is narrower than the certificate: HPLC with the chromatogram and the UV spectrum, specific rotation or a chiral separation, the peroxide value and, if the file allows it, a p-anisidine value, a homologue profile, a residual-solvent screen for the extraction and concentration steps, the metal panel and microbiology.

Insist on a stated limit of quantification for each screen, and on ISO/IEC 17025 accreditation for those tests. A “not detected” entry with no limit attached describes the method, not the oil. Keep the chain of custody: test the sample that was retained, and make sure the report names the lot and the pack.

Comparing two quotations

Six lines belong side by side: the isomer and the CAS number; the assay with its basis and the IU factor; the peroxide value at release; the optical rotation with its conditions; the homologue profile and the source record; and the pack with its lot code. Two quotations that agree on 90% but differ on the isomer or on the peroxide value are not describing the same oil.

The catalog limits sit on the natural tocopherol product page, and the synthetic acetate is described on the vitamin E page. The tests that separate the natural form from the synthetic one are on the identity page; the effect of storage on the peroxide value is on the stability page; the HPLC method is described in the HPLC method note; release practice is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.